![Nortel QPC705 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/nortel/qpc705/qpc705_maintenance-manual_1707058028.webp)
Page 24 of 34
Equipment replacement
553-2601-500A
Standard 2.0
December 1994
Procedure 10
QUX20 Power Unit replacement
1
Set the breakers on the faceplate of the QUX20 unit to OFF.
2
Set the CAB INP breaker on the QUX19 unit to OFF.
3
If equipped, remove the lower EMI shield from the rear of the cabinet.
4
From the rear of the cabinet, disconnect the lead equipped with a
spade connector from the QUX20 unit to TB3 at rear of the
QUX19 unit.
5
Tag and disconnect red and blue wires from terminals 2, 3, 4, and 5
(4 and 5 may be spare) of TB5 at rear of QUX20 unit.
6
From the front of the cabinet, remove the screws securing the QUX20
unit to the cabinet and remove unit.
7
Position replacement QUX20 unit and secure to cabinet with mounting
screws.
8
From the rear of the cabinet, connect the lead equipped with a spade
connector to the terminal at TB3 at the rear of the QUX19 unit.
9
Reconnect red and blue wires to terminals 2, 3, 4, and 5 (4 and 5 may
be spare) of TB5 at rear of QUX20 unit.
10
If required, reinstall EMI shields.
11
Set the required breakers on the front of the QUX20 unit to ON.
12
Set the CAB INP breaker on the QUX19 unit to ON.
CAUTION
Service in the cabinet is interrupted when replacing the main QUX20
power unit.