6-6
OAM&P description
Optical Multiservice Edge 6130 NT6Q92MA Rel 1.0 Iss 1 Standard September 2006
Loopbacks
The OME6130 supports loopbacks on STM-1/4, 10/100BT Ethernet, Gigabit
Ethernet, E1/DS1 and E3/DS3 ports:
•
Facility - the received signal is looped back towards the transmitter port
immediately on entering the interface port. AIS is inserted in the signal
towards the cross-connect on the 2x155/622M aggregate circuit pack.
•
Terminal - the signal is looped back towards the cross-connect on the
2x155/622M aggregate circuit pack just before reaching the interface
transmitter.
provides an overview of terminal and facility loopbacks.
Figure 6-1
Facility and terminal loopbacks
summarizes the supported loopback types for the
different ports and the appropriate AIS alarm conditioning.
Table 6-2
Loopbacks and AIS alarm conditioning
Port type
Facility loopback
AIS injection on
facility loopback
Terminal
loopback
AIS injection on
terminal loopback
STM-n
Yes
Yes
Yes
No
E1/DS1
Yes
Yes
Yes
Yes
Facility loopback
Rx
AIS
STM-1/OC-3 optical interface ports
E1/DS1 and E3/DS3 services
Tx
Terminal loopback
Rx
Tx
Ethernet
interface
Ethernet interface ports
Terminal loopback
Rx
Tx
STM-1/4 interface ports
E1, DS1, E3, DS3 and GE services
10/100BT Ethernet services
10/100BT
Ethernet
services