Cabling specifications 4-9
Meridian SuperNode MSL-100 Intelligent Peripheral Equipment (IPE) Reference Manual MSL14
Switch 3
Switch 4
Switch 5
Switch 6
Switch 7
Switch 8
Switches 3 through 8
contain a binary value of
the number of slaves
connected. Position 8 is
the least significant bit
and the rightmost switch
(see Table 4-Table 8,
"Settings for total number
of slaves - SW 2 on
master XSM" on page
4-9).
3-X
4-X
5-X
6-X
7-X
1-X
Table 4-7 XSM SW3 option settings
SW3 DIP Switch
Meaning of Setting
Bit Position:
Switches 1 - 4
Master XSM
1 through 4-On
Switches 1 - 4
Slave XSM
1 through 4-Off
Table 4-8 Settings for total number of slaves - SW 2 on master XSM (Sheet 1 of
4)
Number of
slave units
Switch position:
3
4
5
6
7
8
0
On
On
On
On
On
On
1
On
On
On
On
On
Off
2
On
On
On
On
Off
On
3
On
On
On
On
Off
Off
4
On
On
On
Off
On
On
5
On
On
On
Off
On
Off
6
On
On
On
Off
Off
On
7
On
On
On
Off
Off
Off
8
On
On
Off
On
On
On
9
On
On
Off
On
On
Off
Table 4-6 XSM SW2 option settings (slave only) (Sheet 2 of 2)
SW2 DIP Switch
Meaning of Setting(ON
= 0 OFF = 1)
Bit Position: