Nortel IVR 2.5/S
Aculab-Based E1 CAS/ISDN PRI Signaling Guide
Product release 2.5/S
Standard 1.0
July 1997
1
Страница 1: ...Nortel IVR 2 5 S Aculab Based E1 CAS ISDN PRI Signaling Guide Product release 2 5 S Standard 1 0 July 1997 1 ...
Страница 2: ...ogress in engineering and manufacturing may warrant IVR and Nortel are registered trademarks of Northern Telecom in the U S and Canada IVR Generator 2 0 S and Meridian 1 are registered trademarks of Northern Telecom DEC and VT 420 are registered trademarks of Digital Equipment Corporation HP LaserJet and ThinkJet are registered trademarks of Hewlett Packard Company X Window System and X are tradem...
Страница 3: ...iii Nortel IVR 2 5 S Aculab Based E1 CAS ISDN PRI Signaling Guide Publication history July 1997 Standard 1 0 release of the Aculab Based E1 CAS ISDN PRI Signaling Guide for Nortel IVR 2 5 S ...
Страница 4: ...RI signaling option hardware 4 2 Installing the Aculab based E1 PRI signaling option software 4 4 Configuring E1 CAS country parameters 4 8 Configuring ISDN PRI country parameters 4 12 Activating the signaling option 4 16 Appendix A Accessing the Service Console Interface A 1 Using a terminal to access the SCI A 2 Using a modem to access the SCI A 3 Using the LAN to access the SCI A 5 Accessing th...
Страница 5: ...ow to connect to the MRSsystem and log in to the SCI Appendix B shows the configurations of the Aculab ACL 30 and ACL 60 E1 cards CINFO cell limitation over DPNSS The CINFO cell is used to pass information from the switch up to the application to allow the application to route calls appropriately However when the call is coming in over DPNSS the CINFO cell can only process three types of informati...
Страница 6: ... system requirements listed here for installing and using the Aculab based E1 CAS ISDN PRI Signaling option update for MRS 3 02 02 Specifically these requirements are MRS 3 02 02 software running on the MRS SCO UNIX Release 3 2 Version 4 2 operating system MRS AP MRS Tower and MRS Rack with at least 32 Mbytes of memory and 128 kbytes of cache memory ...
Страница 7: ...tion which supports several signaling systems The MRS 3 02 01 E1 CAS ISDN PRI option update provides the following enhancements Using the sci maint menu MRS 3 02 02 base package provides the ability to initialize channels for all Aculab hardware based options MRS 3 02 02 also provides new E1 CAS signaling firmware MRS currently supports one Aculab E1 ISDN card per system Both 30 port and 60 port A...
Страница 8: ...th this signaling protocol Signaling features MRS 3 02 02 supports the following signaling features Incoming calls with ANI CLID DNIS Outgoing calls with the capability to send the calling party ID BOUT or CONP cell call conferencing through Aculab s on board switching matrix In addition to the basic functionality listed above Enhanced DPNSS protocol implementation also supports the following func...
Страница 9: ...e so it should already be installed on your MRS This chapter describes how to install the Aculab based E1 PRI Signaling option hardware and software onto your MRS system It also shows you how to configure the SCI country parameters for your desired signaling option The installation is divided into three main steps 1 installing the signaling option hardware 2 installing the signaling option softwar...
Страница 10: ...e proper I O Addressing Board Operation and Hardware Interrupt settings Please read the notes that follow the tables 5 Open the system and find an open slot where you can install the Aculab E1 interface option card s Follow the recommendations in Step 4 6 Remove the PEB cable from the cards that will be connected to the Aculab E1 Interface card 7 Slide the Aculab E1 Interface card into the system ...
Страница 11: ...installation of the Aculab E1 interface option hardware is complete Figure 4 1 Possible PEB bus configurations with the Aculab modules t T PEB bus Additional Modules voice processing fax TTS ASR resources etc t T T t T External Terminator t Internal Terminator ACL 60 E1 PEB 0 PEB 1 ACL 30 E1 Voice Module Processing Voice Module Processing Voice Module Processing Additional Modules voice processing...
Страница 12: ... base system There are two types of signaling option packages you can install CAS signaling option see Procedure 4 2 on page 4 4 Enhanced DPNSS ISDN PRI signaling option see Procedure 4 3 on page 4 7 Procedure 4 2 Installing the CAS signaling option 1 Log in to the MRS or MRS AP as root refer to Appendix A for detailed instructions on logging in and accessing the SCI 2 At the sci prompt type insta...
Страница 13: ...wing messages are displayed Stopping the System Now various messages sci install 4 Wait until the Ready light on the front panel of the MRS begins flashing before continuing This step ensures that all MRS processes were stopped On the MRS AP there is no Ready light to observe just proceed to the next step 5 At the sci install prompt type package and press Enter The following prompt is displayed In...
Страница 14: ...ror messages The system will continue with these messages Installing files Installation complete sci install 7 Remove the diskette 8 Run the Nortel customization script refer to the section Nortel Customization Procedure in Chapter 6 of the Nortel IVR 2 5 S Product Overview Guide 9 Continue with Procedure 4 4 on page 4 9 Note If it is not necessary for you to configure the country parameters then ...
Страница 15: ...restart operations will be to reboot the VRU A prompt then appears asking if you want to continue Are you sure you wish to continue Current continue no yes Continue with operation no Return to the previous menu Continue 3 Enter y and press Enter to continue with the installation The following messages are displayed Stopping the System Now various messages sci install 4 Wait until the Ready light o...
Страница 16: ... messages Searching for the Size file Install in progress Ignore the CUSLIST error messages The system will continue with these messages Installing files Installation complete sci install 7 Remove the diskette 8 Run the Nortel customization script refer to the section Nortel Customization Procedure in Chapter 6 of the Nortel IVR 2 5 S Product Overview Guide 9 Continue with Procedure 4 5 on page 4 ...
Страница 17: ...pt Do you wish to change the country parameters y n 3 Type y to change the current country configuration and press Enter The system displays this prompt Are you using an ACL E1 network card y n 4 Type y and press Enter to continue The system displays this prompt Please enter the number of trunks on your network card 30 or 60 y n If you installed an ACL 30 E1 card enter 30 If you installed an ACL 6...
Страница 18: ...alaysia 17 Mexico 34 EEMA Ericsson E M 1 Australia 18 Morocco 2 Austria 19 Netherlands 3 Belgium 20 New Zealand 4 Brazil 21 Norway 5 China 22 Portugal 6 Denmark 23 South Africa 7 Finland 24 Spain 8 Germany 25 Sweden 9 Hong Kong 26 Switzerland 10 Hungary 27 United Kingdom 11 Italy 28 United States 12 Israel 29 1TR6 13 Japan 30 DASS2 14 Korea 31 DPNSS 15 Luxembourg 32 ETS300 16 Malaysia 33 VN3 17 Me...
Страница 19: ...nt configuration This system will be configured using x country parameters ACL Type xx port ACL Firmware xxxxx Number of DNIS DDI digits x Number of ANI CLI digits x Do you wish to continue the installation y n ATTENTION If you installed the CAS signaling option for Belgium Brazil China Mexico or Malaysia the system prompts you to enter the number of Direct Dialed Inward DDI and Calling Line Ident...
Страница 20: ...t The Nortel xxx Country Parameters have now been installed sci install 10 Make sure that the last installation diskette has been removed from the disk drive 11 At the sci install prompt enter restart and press Enter The system verifies the integrity of the newly installed packages and informs you of any inconsistencies 12 The MRS starts shutting down The system automatically reboots once it reach...
Страница 21: ...s the present country configuration followed by this prompt Do you wish to change the country parameters y n 3 Type y to change the current country configuration and press Enter The system displays this prompt Are you using an ACL E1 network card y n 4 Type y and press Enter to continue The system displays this prompt Please enter the number of trunks on your network card 30 or 60 If you installed...
Страница 22: ... displays the following Do you want to use Enhanced drivers y n 1 Australia 18 Morocco 2 Austria 19 Netherlands 3 Belgium 20 New Zealand 4 Brazil 21 Norway 5 China 22 Portugal 6 Denmark 23 South Africa 7 Finland 24 Spain 8 Germany 25 Sweden 9 Hong Kong 26 Switzerland 10 Hungary 27 United Kingdom 11 Italy 28 United States 12 Israel 29 1TR6 13 Japan 30 DASS2 14 Korea 31 DPNSS 15 Luxembourg 32 ETS300...
Страница 23: ...ess Enter The system responds with the following Do you want to edit the space 0 file y n 9 Type y and press Enter The system prompts you to verify the current configuration This system will be configured using xxx Enhanced parameters ACL Type xx port ACL Firmware xxxxx DPNSS Signalling X X 10 When your International signaling parameters are correct enter y and press Enter The system displays the ...
Страница 24: ...Root for this system build is The UNIX Kernel has been rebuilt Backing up unix to unix old Installing new unix on the boot file system Setting up new kernel environment The system must now be rebooted for the new parameters to take affect The Nortel xxx Parameters have now been installed sci install 15 Make sure that the last installation diskette has been removed from the disk drive 16 At the sci...
Страница 25: ...ribed in Activating the signaling option on page 4 17 If this is part of an upgrade from Release 2 01 S to 2 5 S then it is not necessary to activate the feature Activating the signaling option After the signaling option components hardware and software are installed the option must be activated Contact your Nortel service provider for assistance Make sure the modem is connected to the system for ...
Страница 26: ...n access the Service Console Interface SCI from a dumb terminal a modem through an RS 232 C or using telnet across a LAN See the following sections Using a terminal to access the SCI on page A 2 Using a modem to access the SCI on page A 3 Using the LAN to access the SCI on page A 5 Accessing the SCI on an MRS AP on page A 6 ...
Страница 27: ...sage should display system name MRS Service Access Port Revision 3 02 Copyright 1991 1996 Nortel All Rights Reserved login 4 At the login prompt enter the appropriate account name The default passwords for these accounts are as follows 5 After you log in the system prompts you for your terminal type If the default terminal type displayed is correct press Enter otherwise type in the correct termina...
Страница 28: ...RS to modem cable 2 Set the terminal parameters as follows baud rate 9600 duplex Full data bits 7 stop bits 1 parity even add LF off 3 From the remote location dial in to the modem and wait for an answer Once the modem is connected press Enter The following message should display system name MRS Service Access Port Revision 3 02 Copyright 1991 1996 Nortel All Rights Reserved login ATTENTION No mod...
Страница 29: ... displayed is correct press Enter otherwise type in the correct terminal type Once this is completed the SCI menu is displayed followed by the sci prompt Note On an MRS AP if you log in as root a prompt is displayed At the prompt type usr vrs tools sci b usr vrs and press Enter to access the SCI menu Account Password Used by root profile Trained Service Personnel service access Trained Service Per...
Страница 30: ...NIX workstation Nortel recommends that this command be issued from an xterm window 2 Once the session is connected the following message should display login 3 At the login prompt enter the appropriate account name The default passwords for these accounts are as follows 4 After you log in the system prompts you for your terminal type If the default terminal type displayed is correct press Enter ot...
Страница 31: ...At the login prompt enter the appropriate account name The default passwords for these accounts are as follows 3 After you log in the system prompts you for your terminal type If the default terminal type displayed is correct press Enter otherwise type in the correct terminal type Note If you log in as root a prompt is displayed At the prompt type usr vrs tools sci b usr vrs and press Enter to acc...
Страница 32: ...0 E1 Interface Ports 1 2 3 4 5 6 7 8 I O Address Ports 00 29 on on on off on on off off 0x320 0x323 Tx Port 1 Rx MVIP 80C188 IRQ Select Block PEB1 BNC connectors IRQ Terminator see Note 6 JP33 JP32 JP30 JP29 JP31 JP8 JP1 JP40 JP42 JP41 JP25 JP27 JP28 JP26 12 11 3 10 15 5 JP16 JP38 JP3 S2 S1 JP2 JP6 JP4 JP10 JP9 TX1 RX1 1 1 ON 2 3 4 5 6 7 8 1 ON 2 3 4 5 6 7 8 G100650 ...
Страница 33: ...card 4 Terminate the PEB at both ends to ensure proper electrical characteristics The ACL 30 has built in PEB terminators so you must install the ACL 30 at one end of the PEB cable You must remove all PEB terminators from the resource cards TTS VR Fax on the PEB 5 The ACL 30 uses shared memory range E0000 to EFFFF 6 Only one ACL 30 card per system is allowed BNC Connector Grounding Jumper Port 1 T...
Страница 34: ... 8 I O Address Ports 00 59 on on on off on on off off 0x320 0x323 Tx Port 1 Rx Tx Port 2 Rx MVIP 80C188 IRQ Select Block PEB1 BNC connectors IRQ Terminator see Note 6 JP33 JP31 JP34 JP32 JP30 JP29 JP8 JP1 JP40 JP42 JP41 JP25 JP27 JP28 JP26 12 11 3 10 15 5 JP16 JP38 JP3 S2 S1 JP2 JP6 JP4 JP5 JP7 JP10 JP13 JP11 JP9 JP12 TX1 RX1 TX2 RX2 PEB 2 1 1 1 ON 2 3 4 5 6 7 8 1 ON 2 3 4 5 6 7 8 G100651 ...
Страница 35: ...e the PEB at both ends to ensure proper electrical characteristics The ACL 60 has built in PEB terminators so you must install the ACL 60 at one end of the PEB cable You must remove all PEB terminators from the resource cards TTS VR Fax on the PEB 5 The ACL 60 uses shared memory range E0000 to EFFFF 6 Only one ACL 60 card per system is allowed BNC Connector Grounding Jumper Port 2 TX2 JP34 ON Port...
Страница 36: ...nd Nortel are registered trademarks of Northern Telecom in the U S and Canada IVR Generator 2 0 S and Meridian 1 are registered trademarks of Northern Telecom DEC and VT 420 are registered trademarks of Digital Equipment Corporation HP LaserJet and ThinkJet are registered trademarks of Hewlett Packard Company X Window System and X are trademarks of the Massachusetts Institute of Technology Motif i...