BTR 2400 Release 1.1 1-11
Reunion BTR 2400 Installation Guide
Installing the Tower Equipment
Install the BTR 2400 microwave transceiver as follows:
The radio mounting saddle has no paint on the inside surface in order to
provide a grounding.
1. Ensure that the radio mounting surface on the pole is free of paint to
provide a grounding.
2. Mount the BTR 2400 to a stable pole using the supplied mounting
brackets. The mounting brackets accommodate poles with outside
diameters from 2.5" to 4.5". See Figures 1-4, 1-5 and 1-12.
3. There are four 1/2" 13 UNC threaded rods, along with four hex head nuts
and flat and lock washers. Thread the rod into the saddle bracket, then
tighten with the nut. The flat washer is against the exterior of the bracket,
followed by the lock washer and then the nut.
4. Ensure connectors are facing down.
5. Install the BTR 2400 so that the fin array (heat sink) is positioned away
from external barriers to allow heat dissipation through natural
convection and radiation. See Figures 1-4 and 1-14.
The BTR 2400 requires 60 VAC or 48 VDC power supply unit.
6. Connect the TX/power coaxial cable from the RPE 9000’s TX female N-
Type connector to the BTR’s N-type IF and PS IN port.
7. Connect the RF coaxial cable from the RPE 9000’s RX female N-Type
connector to the BTR’s N-type IF OUT port.
8. Connect the telemetry cable from the BTR 2400 to the RPE 9000’s
telemetry connector. There is a 300 baud modem connection between the
BTR 2400, the RPE 9000 and the RSM 9016. See Figures 1-4 and 1-13.
9. Seal all connections using Coax-Seal®, cold shrink or hot shrink
tubing.
10. Ground all RF cables at the recommended spacing intervals. (Refer to
tower and cable manufacturers’ specifications).
11. Ensure that all feed lines are securely attached to the support structure.
Plan for drip (service) loops on all cables.
12. The BTR 2400 has a vertical range of motion of +10
°
over and -20° under
the horizon, as shown in Figures 1-6 and 1-7.
13. Refer to Outline and Installation Drawing # PO 883482 and the Reunion
Redundancy Switching Matrix Installation Guide, 411-1313-201.
Warning
Do not turn on the power supply until the
installation is complete.
After you install the equipment, check the cable.
Содержание BTR 2400
Страница 1: ...Reunion BTR 2400 Outdoor Microwave Transceiver Installation Guide Release 1 1 July 1998 411 1333 200 ...
Страница 2: ......
Страница 4: ......
Страница 6: ...vi Publication history 411 1333 200 Preliminary July 1998 ...
Страница 36: ...1 24 BTR 2400 Release 1 1 411 1333 200 Preliminary July 1998 ...
Страница 40: ...2 4 List of terms 411 1333 200 Preliminary July 1998 ...
Страница 41: ...Family Product Manual Contacts Copyright Confidentiality Legal statements DocInfo ...