Installing Indoor Equipment
Both the primary and the redundant BTR 2400s are connected to and
switched by the RPE 9000. The RPE 9000 is connected to both the RSM 9016
and the RSM 9116. The RSM 9016 is connected to the SMMs, while the
RSM 9116 is connected to the SDMs. The RSM 9016, RSM 9116, SMMs
(Signal Modulator Module) and SDMs (Signal Demodulator Module) are
installed in the NNE (Network Node Equipment unit). The SMMs modulate
ATM cells for wireless transport, while the SDMs interface RF to digital at
the base station and demodulates the QAM signal.
Install the indoor equipment associated with the BTR 2400 microwave
transceiver as follows:
1. Connect the telemetry cable from the RPE 9000’s telemetry connector to
the RSM 9016.
2. Connect the TX/PS coaxial cable from the RPE 9000 to the RSM 9016.
3. Connect the RX coaxial cable from the RPE 9000 to the RSM 9116.
4. Refer to the Reunion Redundancy Switching Matrix Installation Guide,
411-1313-201.
5. Refer to site specific documentation for detailed information, such as the
supplied engineer’s documentation.
Figure 1-2
Block Diagram showing BTR 2400 indoor set-up
RPE 9000
BTR 2400
A
BTR 2400
B
RSM 9016
RSM 9116
SMMs
SDMs
Telemetry
Telemetry
TX/PS
TX/PS
RX
RX
Telemetry
RX
TX/PS
-48 DC
.......
......
Содержание BTR 2400
Страница 1: ...Reunion BTR 2400 Outdoor Microwave Transceiver Installation Guide Release 1 1 July 1998 411 1333 200 ...
Страница 2: ......
Страница 4: ......
Страница 6: ...vi Publication history 411 1333 200 Preliminary July 1998 ...
Страница 36: ...1 24 BTR 2400 Release 1 1 411 1333 200 Preliminary July 1998 ...
Страница 40: ...2 4 List of terms 411 1333 200 Preliminary July 1998 ...
Страница 41: ...Family Product Manual Contacts Copyright Confidentiality Legal statements DocInfo ...