![Nortel BCM50 Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/nortel/bcm50/bcm50_installation-and-maintenance-manual_1706243046.webp)
46
Chapter 2 Introducing the BCM50 hardware
N0027152 01
N0027152 01
BCM50 hardware
The following BCM50 hardware items simplify the setup and connection of the system:
•
“Rackmount shelf”
•
“Wallmount bracket” on page 47
•
“Patch panel” on page 47
•
“Wiring field card (WFC)” on page 48
Rackmount shelf
To rackmount a BCM50 unit (main unit or expansion unit), you need a rackmount shelf. The
rackmount shelf mounts in a standard 19-inch equipment rack. The BCM50 unit then clips into the
tabs on the rackmount shelf. These tabs prevent the unit from sliding around or falling off the
shelf.
Analog loop resistance
on terminal side for
data applications
(cable only)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
250 ohms (1538
m of 0.5-mm
wire or 5000 ft of
24 AWG wire)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
Input impedance at tip
and ring
600 ohms
600 ohms
600 ohms
600 ohms
600 ohms
Return loss
> 20 dB for 200
to 3400 Hz
(when
terminated with
600 ohms)
> 20 dB for 200
to 3400 Hz
(when
terminated with
600 ohms)
> 20 dB for 200
to 3400 Hz
(when
terminated with
600 ohms)
> 20 dB for 200
to 3400 Hz
(when
terminated with
600 ohms)
> 20 dB for 200
to 3400 Hz
(when
terminated with
600 ohms)
Insertion loss on an
internal call
ATA2 to BCM50
loss 3.0 dB
±
0.5
dB
ATA2 to BCM50
loss 3.0 dB
±
0.5
dB
ATA2 to BCM50
loss 3.0 dB
±
0.5
dB
ATA2 to BCM50
loss 3.0 dB
±
0.5
dB
ATA2 to BCM50
loss 3.0 dB
±
0.5
dB
Insertion loss on an
external call
ATA2 to BCM50
loss 2.2 dB +/-
1.0 dB; BCM50
to ATA2 loss 0.5
dB
±
1.0 dB
ASM to BCM50
loss 3.0 dB +/-
1.0 dB; BCM50
to ASM loss 0.5
dB
±
1.0 dB
ASM to BCM50
loss 3.0 dB +/-
1.0 dB; BCM50
to ASM loss 0.5
dB
±
1.0 dB
ASM to BCM50
loss 3.0 dB +/-
1.0 dB; BCM50
to ASM loss 0.5
dB
±
1.0 dB
ASM to BCM50
loss 3.0 dB +/-
1.0 dB; BCM50
to ASM loss 0.5
dB
±
1.0 dB
MWI type (see Note)
Stutter tone
Stutter tone
Stutter tone/
/ Voltage MWI
(CO: 120 V)
Stutter tone/
Reverse polarity/
Voltage MWI
(CO: 120 V)
Stutter Tone/
Reverse polarity/
Voltage MWI
(PBX: 90 V)
Disconnect
supervision types
N/A
N/A
OSI EIA/TIA 464
section
4.5.10.2.4/
4.5.10.2.5.1
OSI EIA/TIA 464
section
4.5.10.2.4/
4.5.10.2.5.1
N/A
Note: The MWI type depends on the country profile, and the MWI voltage shown is a maximum value.
Table 5 ATA2, ASM8, ASM8+, GASM, and GASI analog device specifications (Sheet 2 of 2)
Specification
ATA2
ASM8
ASM8+
GASM
GASI
Содержание BCM50
Страница 1: ...Part No N0027152 01 08 April 2005 BCM50 Installation and Maintenance Guide ...
Страница 8: ...8 Task List N0027152 01 N0027152 01 ...
Страница 16: ...16 Contents N0027152 01 N0027152 01 ...
Страница 34: ...34 Chapter 1 Getting started with BCM50 N0027152 01 N0027152 01 ...
Страница 58: ...58 Chapter 2 Introducing the BCM50 hardware N0027152 01 N0027152 01 ...
Страница 70: ...70 Chapter 4 Determining DHCP server configuration and IP address N0027152 01 N0027152 01 ...
Страница 74: ...74 Chapter 5 Installing the BCM50 system N0027152 01 N0027152 01 ...
Страница 96: ...96 Chapter 8 Installing an expansion unit N0027152 01 N0027152 01 ...
Страница 116: ...116 Chapter 10 Installing telephones and peripherals N0027152 01 N0027152 01 ...
Страница 122: ...122 Chapter 11 Installing the analog terminal adapter N0027152 01 N0027152 01 ...
Страница 126: ...126 Chapter 12 Configuring the BCM50 system N0027152 01 N0027152 01 ...
Страница 132: ...132 Chapter 13 Using Telset Administration to set the basic parameters N0027152 01 N0027152 01 ...
Страница 148: ...148 Chapter 15 Using the Startup Profile to configure parameters N0027152 01 N0027152 01 ...
Страница 158: ...158 Chapter 17 Connecting the BCM50 system to the LAN and WAN N0027152 01 N0027152 01 ...
Страница 168: ...168 Chapter 19 Replacing the BCM50 system components N0027152 01 N0027152 01 ...
Страница 172: ...172 Chapter 20 Replacing a power supply N0027152 01 N0027152 01 ...
Страница 178: ...178 Chapter 21 Replacing a main unit N0027152 01 N0027152 01 ...
Страница 182: ...182 Chapter 22 Replacing a media bay module N0027152 01 N0027152 01 ...
Страница 214: ...214 Appendix E DTM wiring chart N0027152 01 N0027152 01 ...
Страница 220: ...220 Appendix G GATM wiring chart N0027152 01 N0027152 01 ...
Страница 224: ...224 Appendix H 4x16 wiring charts N0027152 01 N0027152 01 ...
Страница 240: ...240 Appendix K System region attributes N0027152 01 N0027152 01 ...
Страница 246: ...246 Index N0027152 01 N0027152 01 ...