36
Troubleshooting Global Faults
ATTENTION
This issue has been fixed by Sourcefire and Nortel IT team. Perform the steps
in the following procedure if a problem with downloading and importing the SEU
still persists.
Procedure 24
Procedure steps
Step
Action
1
Configure the primary DNS server at the following location:
Mgmt Interface/Netmask/Default Network
Gateway/Domain/Primary DNS Server
2
At the TPS IS/DC command line, ping the Nortel update website
to see if the associated webpage appears.
www.nortel.autoupdates.com
3
Ensure that the time settings on both the TPS IS/DC and the
local PC are the same. On the menu bar choose Operation,
System settings, Time and then Set Time to check the time (for
example: America/Los Angeles, Tuesday, December 12, 2006)
on the TPS. This should match the time on the local PC.
4
Ensure that the SEU downloading and importing are not
scheduled to occur at the same time.
--End--
Troubleshooting when a customer is unable to add a sensor to be
managed by a DC
This section describes the troubleshooting steps when a customer was not
able to add a sensor to be managed by DC. The system responds with the
following output message:
Could not establish a connection with sensor
Procedure 25
Procedure steps
Step
Action
1
Check if the registration keys on the IS and the DC match.
On the IS menu bar choose Operations, System Setting,
Remote Manager and then Add Manager to check the
registration key (for example: Nortel).
On the DC menu bar choose Operations, Sensor, and then
Add new sensor to check the registration key (for example:
Nortel)
Nortel TPS 4.7
Threat Protection System Troubleshooting Guide
NN47240-700
01.01
Standard
1
1
2007
Copyright © 2007 Nortel Networks
.
Содержание 2070
Страница 55: ......