22
Software Troubleshooting
Password reset successfully
Control returns to the root prompt.
--End--
Installing an Old Version of SEU
Use this procedure to install a lower version of Snort Engine Upgrade
(SEU) than that currently installed, for test purposes.
Procedure 5
Procedure steps
Step
Action
1
Enter the following command to query the versions of SEUs
currently installed.
run rpm -qa
2
Enter the following sequence of commands to install an earlier
version of an SEU.
rpm -e snort-#.#.#-##
rpm -e Sourcefire_Module_Pack-#-dev
rpm -e Sourcefire_Rule_Pack-##-vrt
rpm -e Sourcefire_Snort_Engine_Upgrade-##-###
where the character # represents placeholders for the current
version.
CAUTION
Do not enter any other rpm -e commands at the
command prompt except the ones listed in step 2.
--End--