InstallatIon / PErForMancE chEcK lIst
hEatInG / coolInG sYstEM
All earth loops received, installed, and
grouted according to the instructions in
the earth loop installation guide?
YES
NO
Operational Compressor Amps: ......................................
Operational Air Handler Amps: ........................................
Compressor Suction Psig Pressure: ____ Temp. (° F) _________
Compressor Discharge Psig Pressure: ____Temp. (° F) ________
Total Amps: ____________ Volts _________________
Fan speed: High_______ Medium ________ Low __________
CFM Airflow: ....................................................................
hEatInG MoDE
Supply Air Out of Air Handler (DB): ................................ (° F)
Return Air Into Air Handler (DB): .................................... (° F)
Superheat .......................(° F) at Compressor in Heating Mode
Temperature Differential
Δ
T (DB) .................................... (° F)
coolInG MoDE
Supply Air Out of Air Handler (DB): ................................ (° F)
Return Air Into Air Handler (DB): .................................... (° F)
Superheat .......................... (° F) at Compressor in Cooling Mode
Temperature Differential
Δ
T (DB) .................................... (° F)
Supply Air RH _____________ % Return Air RH ___________ %
Identify each well and its respective line set location and length (between the
compressor unit and well). Maintain a site diagram for future location reference in
your files. Give an extra copy to the owner. Provide line set lengths, as well as liquid
and vapor line tubing size in each line set (line sets should all be the same size):
Number of borehole(s) or Earth Loop(s): ____________________
Depth of each borehole or Earth Loop ___________________ (Ft)
lInE sEt sIzE:
Vapor line O.D. (Inches): ______ Liquid line O.D. (inches) _______
Line set distances to each well _____________________
DIstancE BEtWEEn thE coMPrEssor anD thE aIr hanDlEr
Distance (feet) __________________________________
tuBInG sIzE
Vapor line O.D. (Inches): ______ Liquid line O.D. (inches) _______
InstallatIon aDDrEss:
CITY:
STATE:
UNIT MODEL #
UNIT SERIAL #
Unit Installed minimum clearances per
YES
NO
InstallEr naME:
CITY:
STATE:
Has the owner’s information been
reviewed with the customer?
YES
NO
Has the literature packet been left
with the unit?
YES
NO
ElEctrIcal sYstEM
Electrical connections tight?
YES
NO
Line voltage polarity correct?
YES
NO
Has the thermostat been calibrated?
YES
NO
Is the thermostat level?
YES
NO
sInGlE PhasE unIts
Rated Voltage: ................................................................. VOLTS
L1-L2 Volts: ...................................................................... VOLTS
3–PhasE unIts
Rated Voltage: ................................................................. VOLTS
L1-L2 Volts: ...................................................................... VOLTS
L1-L3 Volts: ...................................................................... VOLTS
L2-L3 Volts: ...................................................................... VOLTS
Avg. Volts: ........................................................................ VOLTS
Max. deviation of voltage from avg. volts: ........................ VOLTS
% Volt Imbalance: ............................................................ VOLTS
Duct sYstEM
Filter(s) secured in place?
YES
NO
Filter(s) clean?
YES
NO