Doc No. 702105  Page 4 of 16 

3. Technical Specifications. 

 

Air curtain model 

AB 175E  

 AB 225E 

Air distribution  fans 

 Type 

Centrifugal (with integral thermal trip) 

 Speeds 

 No. of fans 

3  

 Maximum air volume 

9600m

3

/hr  

12800m

3

/hr  

 Voltage 

230V 1PH 50Hz 

 Power rating (per fan) 

1140 W 

 Current (per fan) 

5.2A (FLC) 

 Start current (per fan) 

12A 

Power 

 Elements 

18kW 24kW 

 Total  power consumption 

21.42kW  

 30.56kW 

Temperature rise (

 T) 

 High speed 

9.7°C 7.28°C 

 Low speed 

 13.86°C 

10.39°C 

 

WARNING: 

 

THIS AIR CURTAIN SHOULD NOT BE 
INSTALLED WHERE THERE IS A   
CORROSIVE ATMOSPHERE. 

Содержание AB 175E

Страница 1: ...Replacement 7 Spare Parts 8 Fault Finding 9 User Instructions 10 WARNINGS 1 This appliance must only be installed by a competent person in accordance with the requirements of the Codes of Practice or...

Страница 2: ...g an air curtain is to prevent the influx of cold outside air through a door opening into a heated area Typical applications include large despatch bay doors in factories and warehouses and internal d...

Страница 3: ...Doc No 702105 Page 3 of 16 2 Dimensions Diagram 1 Dimensions FRONT VIEW PLAN VIEW R H VIEW...

Страница 4: ...ans 3 4 Maximum air volume 9600m3 hr 12800m3 hr Voltage 230V 1PH 50Hz Power rating per fan 1140 W Current per fan 5 2A FLC Start current per fan 12A Power Elements 18kW 24kW Total power consumption 21...

Страница 5: ...e air curtains should be bolted together using 3 off M10 set pins nuts and washers fitted through the holes provided in the mounting brackets then suitable support channels not supplied must be fixed...

Страница 6: ...R CURTAIN Diagram 4 Support channel multiple air curtains Typical support channels Air curtain 1 Air curtain 2 PLAN VIEW TWIN AIR CURTAINS Factory fitted brackets Support points 4 Installation Details...

Страница 7: ...ector switch a high low fan speed selector switch and a heat on off selector switch Panel operation is described in section 10 of this manual user instructions A customer specific control panel wiring...

Страница 8: ...ution fans can be accessed by opening the fan access lid as described in section 7 1 Fig 2 Clean off any dust or deposits with a soft brush paying particular attention to the impeller Check that the i...

Страница 9: ...the retaining screws securing the hinged lid on the underside of the air curtain next to the louvres Fig 3 7 Parts Replacement Fig 5 Fan closure plate Fan outlet Fig 3 Fig 4 Fig 6 Fan closure plate F...

Страница 10: ...equiring removal and disconnect it from its cable mount ed plug socket See Fig 7 The four bolts securing the fan can now be removed as shown in Fig 8 and the fan removed from the air curtain downwards...

Страница 11: ...ightly and lifted from the 3 retaining tab slots D See diagram 8 7 2 5 The wiring to the element assembly can now be accessed at the rear of panel E and disconnected after first noting the cable posit...

Страница 12: ...date the warranty of the appliance AB 225E 24kW elements full set 100528 AB 175E 18kW elements full set 100527 Thermal cutout 1 per module 900001 8 Spare Parts Item Description Part No 3 speed air dis...

Страница 13: ...ntactor and associated wiring All air distribution fans off YES If the fan s still fail to operate normally please contact the Nortek service department YES Check 1 Power supply YES NO Air distributio...

Страница 14: ...vice department YES Check 1 Power supply YES NO Elements NO Low heat Check 1 Check current load on all elements Should be balanced If not could be element s open circuit If it is determined that the o...

Страница 15: ...Doc No 702105 Page 15 of 16 Notes...

Страница 16: ...h to the desired position 10 3 2 Switch on electrical supply to the control panel The panel live lamp will illuminate and the unit will now only operate when the BMS relay or remote switch is closed 1...

Отзывы: