4 6-050700
X2
212iLW & 242iLW Standalone Keypad
Installation & Programming Manual
2. Speci
fi
cations
Parameter
Range/Description
Voltage
10–30 VDC, 12-24 VAC (Auto-Adjusting)
Current
93 mA @ 10 VDC; 158 mA @ 30 VDC,
148 mA @ 12 VAC; 198 mA @ 24 VAC
242 Model - Add 25 mA for each energized aux
relay (max = 75 mA)
Environment
For Indoor and Outdoor Use
Temperature Tolerance
-20° F to 130° F (-28° C to 54° C)
Dimensions
5-1/8" H x 3-3/8" W x 5/8" D
Main Relay (Form C)
Contact Rating: 2 A @ 30 VAC/DC
Aux Relay (Form C)
Contact Rating: 1 A @ 24 VAC/DC
REX Input
Normally Open Dry Contact
Door Position Input
Normally Closed Dry Contact
LEDs
Bi-Color Red/Green; Yellow
Default Keypad Settings
Parameter
Default Setting
Master Code
1234
Lock Output
Relay 1 (Main relay – 212 and 242)
Alarm Shunt Output
Relay 2 (242)
Propped Door Output
Relay 3 (242)
Forced Door Output
Relay 4 (242)
Audio Alerts
Not Assigned (212 and 242)
REX
Triggers Lock Output
REX Operation
Always Triggers (regardless of Door Loop)
Error Lockout
Enabled
Error Lockout Threshold
3 Attempts
Error Lockout Duration
10 Seconds
Lock Output Time
5 Seconds
Propped Door Output Time
30 Seconds
Forced Door Output Time
10 Seconds
Visual Keypress Feedback
Enabled
Audio Keypress Feedback
Enabled
Auto-Entry
Disabled
User Lockout
Enabled