6-050700 X2
17
212iLW & 242iLW Standalone Keypad
Installation & Programming Manual
Command/Action
Keys to Enter/Details
Command 10.
Assign Virtual
Outputs to Physical
Outputs
10 # virtual output # physical output #
✱ ✱
Virtual Output List
Physical Output List
0 – No Mapping
1 – Relay 1 (Main Relay)
(Physical output unused)
2 – Relay 2 (K2); (242 model)
1 – Lock Output*
3 – Relay 3 (K3); (242 model)
2 – Alarm Shunt Output (242)
4 – Relay 4 (K4); (242 model)
3 – Propped Door Output**
9 – Audio Alert #1
4 – Forced Door Output**
10 – Audio Alert #2
5 – OUT2 (242)
6 – OUT3 (242)
Note: Audio alerts are described
7 – OUT4 (242)
in Section 7.2.2
8 – OUT5 (242)
13 – Duress Output (242)
14 – Panic Output (242)
15 – Keypad Active Output (242)
* The bi-color red/green LED only follows the lock output.
** On the 212 model, you can assign these to the audio alerts.
Defaults
– The keypad comes
programmed with the following
default output assignments:
The Lock Output is assigned to
Relay 1, the Alarm Shunt Output to
Relay 2, the Propped Door Output to
Relay 3 and the Forced Door Output
to Relay 4.
7.2.1 Virtual Outputs
Virtual Outputs
Description/Details
Lock
This output is used for your locking device.
Alarm Shunt (242)
This is used to shunt out an existing alarm panel.
It activates with the lock output and de-energizes
one second after the lock time expires.
Propped Door
This output activates after entering a valid user
code only if the door position switch is left open
longer than the programmed propped door time.