![Nortech PD160 Enhanced Series Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/nortech/pd160-enhanced-series/pd160-enhanced-series_user-manual_1705859007.webp)
304UM0001 Rev 00
PD160 Enhanced Series User Manual
Page: 7 of 39
2.2 Electrical Data
Power requirements
120 V
AC
± 10% (48 to 62Hz)
(PD161)
230 V
AC
± 10% (48 to 62Hz)
(PD162)
Requirement: 1.5 VA Maximum @ 230 V
12 V -10% to 24 V +10% DC/AC (48 to 62Hz) (PD164)
Requirement: 1 VA Maximum @ 12 V
Relay Contact Rating
Relays rated – 1 A @ 230 V
AC
Optional – Opto Isolated 50mA @ 30V
DC
For ambient temperatures above 60°C De-rate the rel ay
maximum current as per graph below:
2.3 Environmental Data
Storage Temperature
-40°C to +80°C
Operating Temperature
-30°C to +70°C (as a funct ion of the LCD)
(below -20°C the LCD response time is affecte d)
Humidity
Up to 95% relative humidity without condensation
Circuit protection
Conformal coating over the PCB and all components
IP Rating
IP30 – This product MUST be installed in an enclosure