307UM0100_01 May 2016
PD17x User Manual
Page 6 of 31
2.2 Electrical Data
Power requirements
120V AC ± 10% (48 to 62Hz)
(PD171)
230V AC ± 10% (48 to 62Hz)
(PD172)
Requirement: 1.5 VA Maximum @ 230 V
12-24V ± 10% DC/AC (48 to 62Hz) (PD174)
Requirement: 1 VA Maximum @ 12 V
Relay Contact Rating
Relay contact ra�ng: 2A@30VDC, 0.5A@125VAC, 0.25A@250VAC
For ambient temperatures above 60°C de-rate the relay
Maximum current as per graph below:
2.3 Environmental Data
Storage Temperature
-40°C to +80°C
Opera�ng Temperature
-40°C to +80°C
Humidity
Up to 95% relative humidity without condensa�on
Circuit protec�on
Conformal coa�ng over the PCB and all components
IP Ra�ng
IP30 – This product MUST be installed in an enclosure
2.4 Mechanical Data
Housing Material
ABS blend
Moun�ng Posi�on
DIN rail moun�ng or Shelf
Connec�ons
11-pin Submagnal (JEDEC No. B11-88) OR
2x 6 way Plugs on DIN Rail Mount