- 7 -

Item

Part Number

Description

Qty

1

2522174

Cabinet, Shell, Blower Pack

1

2

1473002

Terminal Block 2 Pole - WECO P/N 327-FU

1

3

1323020

Ground Clamp

1

4

1323082

Terminal Strip 2 Pole

1

5

2522070

Relay 30A 115V SPDT

1

6

1453055

Fuse Holder for MDA, S.O Term

2

7

2524202

Fuse 0.75amp 250V 0.25x1.25 slow blow

2

8

2524083

Fuseblock 2 pole for 2524082

1

9

2524082

Fuse 1 amp 600V, HCTR Slow Blow (Edison)

2

10

2522064

TX 100VA 115-208 230 277

1

11

2522177

Plate SS, Distributor, Blowerpack

1

12

2522179

Distributor plastic Blower Pack

1

13

2522178

Distributor Faceplate Blower Pack

1

14

1475005

Thermostat O-Ring

1

15

1073005

Thermostat Control (Non-Reset)

1

16

2524056

Hex Nut #2-56,Steel Zn plated

2

17

2522176

Cabinet, Fan Housing, Blowerpack

1

18

2522065

Fan Box 115V 110CFM 120x120x38mm

3

19

1504281

Fan cover 4in

6

20

1708808

Hex Nut #10-32,SS

8

21

2524080

Screw Selftapping, lin, #10-32, Philips Flat Head

24

22

1325032

Screw 8-32 x 0.5 TA

2

23

2522175

Cabinet, Cover, Blower Pack

1

24

2522200

Thumb screw .250-20 x .5" lg, nylon

2

25

2524057

Fan Box 115V 130CFM 120x120x38mm

1

26

2524204

TX 100VA 115-380V, 50-60 Hz

1

27

1328650 (1)

RW25 Rubber Extrusion

1

OPTIONAL BLOWER PACK REPLACEMENT PARTS FOR NH, SE, GS models

Содержание BLOWER PACKS

Страница 1: ...WER PACKS All Atmospheric Humidifiers Installation Troubleshooting and Exploded Views IMPORTANT Read and save this guide for future reference This guide to be left with equipment owner Form 07 239 1506261 ...

Страница 2: ......

Страница 3: ... WALL MOUNTING 1 REMOTE MOUNTED BLOWER PACKS STEAM LINE 2 CONDENSATE RETURN LINES 3 PRIMARY VOLTAGE CONNECTION 3 PRIMARY VOLTAGE SUPPLY WIRING FROM HUMIDIFIER S TO BLOWER PACK 4 BLOWER PACK CLEARANCES AND DIMENSIONS 5 EXPLODED VIEW OF THE BLOWER PACK 6 7 WIRING DIAGRAM 8 ...

Страница 4: ......

Страница 5: ...ed that balancing valves be used on the steam supply lines to multiple blower packs for equal loading REMOTE MOUNTED BLOWER PACKS WALL MOUNTING 1 Steam and condensate line connections are on the bottom of the blower pack The condensate connection is 3 8 and the steam lines are 7 8 or 1 depending The knock out for the appropriate steam connection must be removed prior to mounting on the wall To rem...

Страница 6: ...s This will also reduce the back pressure and avoid the need to install an extended water trap 5 Ensure that the steam hose does not kink or sag The steam hose becomes more flexible when hot The hose should be supported to prevent water traps Only use steam hose for connection or steam line runs of 5 feet or less See Figure 4 6 To ensure odor free steam always use NORTEC steam hose Check steam hos...

Страница 7: ...ng of condensate return lines Condensate that accumulates in trap will prevent possibility of steam escaping Depth of the trap must be equal or more than 3 76 mm See Figure 6 3 Ensure the trap is 3 minimum under the blower pack and as close to the floor drain as possible PRIMARY VOLTAGE CONNECTION 1 All blower packs for SE and GS unit are wired by others to be powered by an independent circuit 2 A...

Страница 8: ...TAGE SUPPLY WIRING FROM HUMIDIFIER S TO BLOWER PACK 1 All blower packs are wired by factory if built on and to be powered from the humidifier 2 All built on blower packs are factory wired to the humidifier Primary voltage wiring to the humidifier as described in electrical primary voltage supply wiring is all that is required to power the humidifier and blower packs 4 ...

Страница 9: ...6 91 42 106 48 122 42 106 48 122 Min Front Clearance Inches cm 30 76 30 76 36 91 72 183 84 213 144 366 156 396 144 366 156 396 Remote mounted only Four remote mounted blower packs are recommended on the 200 model Nominal conditions 72 F 35 RH OverheadAnd Frontal Clearances For Blower Packs Note Add 8 70 22 cm to the over all unit height for BOBP for NHTC NHPC Only Blower Pack Weight 120V model 12 ...

Страница 10: ... Packs Installation and Exploded Views 7 22 14 8 3 18 19 2 11 13 15 16 NOTE ITEMS 30 AND 31 NOT SHOWN ITEM 30 CAN REPLACE ITEM 18 AND ITEM 31 CAN REPLACE ITEM 10 IN DIFFERENT WORKING CONFIGURATIONS 9 10 1 20 4 5 6 12 25 17 24 27 28 26 23 21 29 ...

Страница 11: ...ributor plastic Blower Pack 1 13 2522178 Distributor Faceplate Blower Pack 1 14 1475005 Thermostat O Ring 1 15 1073005 Thermostat Control Non Reset 1 16 2524056 Hex Nut 2 56 Steel Zn plated 2 17 2522176 Cabinet Fan Housing Blowerpack 1 18 2522065 Fan Box 115V 110CFM 120x120x38mm 3 19 1504281 Fan cover 4in 6 20 1708808 Hex Nut 10 32 SS 8 21 2524080 Screw Selftapping lin 10 32 Philips Flat Head 24 2...

Страница 12: ...LOWER PACK SPECIFICATION LABEL FOR APPROPRIATE VOLTAGE BLOWER PACK LV TERMINAL BLOCK ON OFF LOOP TO BE WIRED TO HUMIDIFIER WITH OTHER ON OFF CONTROLS IN SERIES S STEP DOWN TRANSFORMER Not required for 115V Model S 0 75A FUSES S S 1 A FUSES Not required for 115V Model 115 VAC BLOWER PACK FAN KIT Orange 550 600V Yellow 440 480V Brown 277V Red 230V Black 208V White Common Transformer Primary Supply C...

Страница 13: ...implied by law No liability whatsoever shall be attached to THE COMPANY until said products have been paid for in full and then said liability shall be limited to the original purchase price for the product Any further warranty must be in writing signed by an officer of THE COMPANY THE COMPANY s limited warranty on accessories not of AXAIR NORTEC s manufacture such as controls humidistats pumps et...

Страница 14: ......

Страница 15: ...WMH COMPANY www humidity com U S A AxAir NORTEC Inc 826 Proctor Avenue Ogdensburg New York 13669 CANADA AxAir NORTEC Ltd 2740 Fenton Road Ottawa ON K1T 3T7 1 866 NORTEC 1 Fax 613 822 7964 J xl ir Nortec aWMH Company ISO IJ ...

Отзывы: