13
Chimney Connector Clearances
The stove position will be determined by the greater
of either the stove clearance or the chimney connector
clearance above (x) and to the side (y). See
Fig. 9
.
Single Wall Pipe:
Unprotected Surface: 18”/485 mm
Protected Surface: 6”/153 mm
Double Wall Pipe: Mfg’s Listing
Clearance to Combustible Materials
•
The clearances listed and diagramed in this manual
have been tested to UL and ULC standards and are
the minimum clearances to combustible materials
specifically established for the Norsk Kleber Kube
models.
•
A combustible surface is anything that can burn
(i.e. sheet rock, wall paper, wood, fabrics etc.).
•
Any combustible material must be kept 36” (914
mm) away from the stove load door and at least
18” (457 mm) from the sides.
•
Combustible materials are not limited to those
that are visible and also include materials that
are behind noncombustible materials. “Fire
Resistant” or ”Fire-rated” materials are considered
combustible; they are difficult to ignite, but will
burn.
•
Consult your local fire officials if you are unsure of
the combustible nature of any material.
Clearance to Walls & Ceilings
See the table in
Fig. 8
for specific wall clearance
requirements using either single or Listed double-wall
connectors.
Minimum Ceiling Height: 72”/183 cm
The is approved for use with Listed double wall
pipe installed to conform to the clearances in
Fig. 9.
Wall-Mounted Protection: When reducing clearances
through the use of wall-mounted protection:
For the U.S., refer to NFPA 211, Standard for
Chimneys, Stoves, Vents and Solid Fuel Burning
Appliances, for acceptable materials, proper sizing and
construction guidelines.
For Canada, refer to CAN/CSA-B365, Installation
Code for Solid-Fuel Burning Appliances and
Equipment, also for acceptable materials, proper sizing
and construction guidelines.
Chimney Connection
Use 6 in. flue connector made
form 24 gauge or heavier
steel.
Chimney Connector Clearances:
The stove position will be determined
by
the greater of either the stove clearance or
the chimney connector clearance above
(x) and to the side (y).
(x) Connector to Ceiling 19”
(y)Connector to Parallel Wall 19”
Notice:
Many manufacturers have developed
woodburning stove accessories that permit
clearance reduction. Use only those accessories
that have been tested by an independent
laboratory and carry that laboratory’s
testing mark. Be sure to follow all of the
manufacturer’s instructions.
Rear exit chimney
connector clearance
Fig 9
Содержание Kube 3
Страница 17: ...Exploded view ...
Страница 28: ...Exploded Parts View ...