background image

CONFIDENTIAL AND PROPRIETARY 

 

©Norsat International Incorporated (“Norsat”) All Rights 

Reserved 

2021-02-16 INS001201 Rev B

 

 

22

 

2.6 

Ethernet Interface (ATOMControl™ Web Interface)

 

 

On units equipped with the Ethernet option, an integrated HTTP Web Server allows the user to access a 
web based version of the ATOMControl software to control the unit.  To access this application, an Ethernet 
link to the ATOM must be established.  Refer to Section 2.4 for cable connection details.  Once the cable 
is fabricated, connect the Ethernet jack to the network (either through an Ethernet switch or directly to the 

host computer’s RJ

-45 port) and power on the ATOM unit. 

 

2.6.1  Default IP Address 

 

The default IP Address for the ATOM unit is 192.168.77.30 and default the subnet mask is 255.255.255.0.  

Ensure  the  computer’s  IP  Address  is  on  the  same  logical  network  and  subnet  as  the  ATOM  unit  (e.g. 
192.168.77.XXX, where XXX is any number except “30”).  

 

 

2.6.2  Acces

sing ATOMControl™ Web Interface

 

 

The  ATOMControl™  Web  Interface  is  accessed  through  any  web  browser  such  as  Mozilla  Firefox 

(recommended), Google Chrome, Opera, or Internet Explorer.  To access the web interface, launch the 
web browser and type in the IP Address for the ATOM: 

http://192.168.77.30/index.html

 

A simplified version of the ATOM Control software will load in the browser window. 

 

2.6.3  Usin

g ATOMControl™ Web Interface

 

 

The Web Interface use and operation is identical to the ATOMControl interface.  Refer to the ATOMControl 
Software Manual for instructions on how to use the web interface (Norsat document number INS001219). 
 

2.6.4 

Changing the ATOM’s IP Address

 

 

The  factory  default  IP  address  of  the  BUC  is  192.168.77.30  but  it  can  be  user  configured  through  the 

Network  and  Port  Configuration  webpage.    To  change  the  ATOM’s  IP  Address,  connect  the  ATOM  as 

described above, launch a web browser, and then navigate to the following address: 

http://192.168.77.30/index_conf.html

 

Specify the desired IP Address in the text boxes and then click on the “Save Settings and Reboot” button.  

Once the web server reboots, the Web Interface will be accessible through the new IP Address 

http://<New_IP_Address>/index.html 

WARNING: TAKE CARE TO RECORD THE NEW IP ADDRESS WHEN MAKING CHANGES. 

 

Содержание ATOM-100060

Страница 1: ...1 USER MANUAL ATOM Ka 25 40W 50W BUC SSPA ...

Страница 2: ...s to improve reliability function or design Norsat does not assume any liability arising out of the application or use of any product or circuit described herein Norsat does not convey any license under its patent rights or the rights of others Technical Support This manual provides engineers with information necessary to operate the applicable system Technical support is available from Norsat Nor...

Страница 3: ...nd Terminal 12 2 3 J3 DC Power 12 2 3 1 Connector Type 12 2 3 2 DC Unit J3 Connector Pinouts 13 2 4 J2 Monitor and Control Interface 13 2 4 1 Monitor and Control Interface Pinout 14 2 4 2 Ground Pin s Pin G 15 2 4 3 Mute Control Pin D 15 2 4 4 RS 485 Port Pins A B C J 16 2 4 5 RS 232 Port Pins E F G 16 2 4 6 Ethernet Interface Pins E F H K 16 2 5 Serial Port Software Interface 17 2 5 1 Controller ...

Страница 4: ...ound Connection 24 2 9 Fault Indicator LED 24 2 9 1 Description of Operation 24 2 9 2 Modes of Operation 24 2 9 3 Starting with No Faults Status 24 2 9 4 Fault and No Faults 24 3 Misc Info 24 3 1 ATOM Installation 24 3 1 1 Mounting 24 3 1 2 Outdoor Use 25 3 2 Fans Baseplate Cooling 25 3 3 Accessories 25 3 4 General Specifications 25 3 5 Standard Warranty 26 Appendix A Mechanical Drawings 27 Append...

Страница 5: ...ATOM Ka 25W 40W units 11 Figure 2 6 Standard Waveguide Output for ATOM Ka 50W units 11 Figure 2 7 DC Unit J3 Connector Pinout 13 Figure 2 8 J2 M C Connector Pin Arrangement 14 Figure 2 9 RJ 45 Plug Pinout 17 Figure 2 10 Setup Serial Port 18 Figure 2 11 Command getident 18 Figure 2 12 Command getstatus 19 Figure 2 13 Command getfaults 19 Figure 2 14 Command resetfaults 20 Figure 2 15 Command setmut...

Страница 6: ... 7 Table 2 1 DC Unit J3 Connector Pinout 13 Table 2 2 M C Interface Options 14 Table 2 3 J2 Pinouts for ATOM Configurations 14 Table 2 4 ATOM Mute Control Behavior 15 Table 2 5 Ethernet Cable Pinout 16 Table 2 6 Fault Trip and Reset Points 19 Table 2 7 Commands Summary 21 Table 3 1 General 25 50W ATOM Specifications 25 Table B 3 1 Acronyms and Abbreviations 31 ...

Страница 7: ...30 0 31 0 GHz Dual Band 29 0 30 0 GHz 30 0 31 0 GHz or Specific Bands This also includes the ATOM 100060 Ka 40W BUC as specified 1 1 1 SSPA Solid State Power Amplifier If this unit is a SSPA the RF input signal is amplified to the specified power 1 1 2 BUC Block Up Converter and Amplifier If this unit is a BUC the IF input signal is upconverted to Ka Band RF frequencies and then amplified to the s...

Страница 8: ... prior to powering on the ATOM W A R N I N G RF Radiation Hazard The ATOM emits high power RF energy which is harmful to the human body Do not operate ATOM unless the RF output flange is either terminated in an RF load 100W min or connected to the feed of a terminal Do not obstruct the RF output or feed output with any body part W A R N I N G Do not allow equipment to be standing in water While th...

Страница 9: ...the output side The interface for these connectors is detailed in this document On the input side there are the following connectors J1 IF or RF Input N Type Jack for BUC K Type Jack for SSPA J2 Ten pin circular connector for M C J3 Four pin circular DC power connector J6 Ground terminal Figure 2 1 Input Connections for ATOM Ka 25W 40W BUC Unit N Type Jack Shown J3 Figure 2 2 Input Connections for...

Страница 10: ...t International Incorporated Norsat All Rights Reserved 2021 02 16 INS001201 Rev B 10 Figure 2 3 Input Connections for ATOM Ka 50W BUC Unit N Type Jack Shown J3 J1 J6 J2 Figure 2 4 Input Connections for ATOM Ka 50W SSPA Unit J2 J6 J3 J1 ...

Страница 11: ...ated Norsat All Rights Reserved 2021 02 16 INS001201 Rev B 11 On the output side there is one connector J4 WR28 waveguide RF output J4 Figure 2 6 Standard Waveguide Output for ATOM Ka 50W units J4 Figure 2 5 Standard Waveguide Output for ATOM Ka 25W 40W units ...

Страница 12: ... a mating connector for the power interface Refer to specific configuration of the unit for the exact voltage range Power is supplied through a four pin type cylindrical connector Two pins are used to deliver the positive connection and two pins are used for the negative connection in order to reduce resistance The negative connection is internally connected to case ground The negative power conne...

Страница 13: ...ternally It is recommended to apply the supply voltage evenly to both pairs of pins to evenly share the current among both sets of wires pins The internal capacitance between the V and V terminals is approximately 120 microfarads 2 4 J2 Monitor and Control Interface The M C interface is used to control the unit with a host computer All on board sensors are accessed through this interface Use of th...

Страница 14: ...be used to add options to the plug such as right angle stress relief clamp metal color finish etc Please contact the connector manufacturer for more information and or refer to Amphenol catalog 12 070 Figure 2 8 J2 M C Connector Pin Arrangement Table 2 3 summarizes the various pinout options for the 25 50W ATOM Ka Note that the pin function varies according to the M C interface option that the ATO...

Страница 15: ...er transistors are turned off reducing power consumption and providing an RF output noise close to the thermal noise floor The operation of this pin is fully configurable through the M C Interface Pin D can be biased with either an internal Pull Down to 0V or an internal Pull Up to 4V Pin D is also configurable to be either active high 3 5V on Pin D will mute the unit or active low 0 0 8V on Pin D...

Страница 16: ...h carries a signal from the unit to the host computer Ensure these are connected to the host computer RS 485 port accordingly A TX RS 485 Host computer TX signal signal into unit B TX RS 485 Host computer TX signal signal into unit C RX RS 485 Host computer RX signal signal out of unit J RX RS 485 Host computer RX signal signal out of unit 2 4 5 RS 232 Port Pins E F G These pins form a standard RS...

Страница 17: ...o unit E Wht Org 3 Ethernet host computer Rx signal signal out of unit Blu 4 Wht Blu 5 H Org 6 Ethernet host computer Rx signal signal out of unit Wht Brn 7 Brn 8 Figure 2 9 RJ 45 Plug Pinout 2 5 Serial Port Software Interface Communications to and from the serial interface is character based Use any standard Terminal program with setup parameters as shown in Figure 2 10 ...

Страница 18: ...s are returned immediately though the precise command response delay varies slightly based on the specific command 2 5 2 Message Definitions getident This command returns the part number software revision and serial number of the unit Figure 2 11 Command getident getstatus This command instructs the unit to respond with fault flag forward power and temperature Note reverse power revpwr in the resp...

Страница 19: ...rs faults under certain conditions Note that the mute fault code indicates muted state not necessarily an error Since the unit can be commanded into mute state without a fault the resetfaults command will not clear a mute fault in this situation The temperature sensor has a trip point above which a fault is triggered and a reset point below which a fault is automatically cleared The reset point is...

Страница 20: ...perates on a command response format Each time a command is entered a response will be displayed If a command executed correctly an ok along with potential parameters and values will be displayed Otherwise err will be displayed along with a description of the error The potential errors that may be displayed are Invalid Command The command was not recognized Invalid Parameter The parameter was not ...

Страница 21: ...determine the specific fault s fwdpwr forward power value in dBm revpwr currently not used but reserved for reverse power temp internal system temperature in degrees Celsius getfaults None ok mute mute_flag overTemp temp_flag pll pll_flag where mute_flag 0 unit unmuted or 1 unit muted temp_flag 0 temp ok or 1 error over temp condition exists pll_flag 0 pll ok or 1 error pll loss of lock resetfault...

Страница 22: ...accessed through any web browser such as Mozilla Firefox recommended Google Chrome Opera or Internet Explorer To access the web interface launch the web browser and type in the IP Address for the ATOM http 192 168 77 30 index html A simplified version of the ATOM Control software will load in the browser window 2 6 3 Using ATOMControl Web Interface The Web Interface use and operation is identical ...

Страница 23: ...to the desired setting Ethernet Method alternate method 5 Connect the ATOM s Ethernet port directly to a computer running Microsoft Windows and power on the ATOM 6 Disable any wireless connections if present 7 Launch a command prompt window Start Run cmd 8 Type in the following command and press the carriage return key Tx arp a cr 9 A list of all Ethernet devices connected to the computer will be ...

Страница 24: ...FAULT and NO FAULTS 2 9 3 Starting with No Faults Status The Status LED will flash once for a lapse of approximately one second every time the power of the device in recycled to OFF and set back to ON If no fault is detected in the device at the Power Up the led will go to OFF afterwards settling in that state 2 9 4 Fault and No Faults In the event of a PLL Fault or an Over Temperature Fault the S...

Страница 25: ...ensure there is adequate cooling to remove heat and prevent the unit from overheating The ATOM is also available with a flat plate in place of the radiators and fans It is the user s responsibility to ensure that the plate the unit is mounted to is capable of rejecting any heat produced by the unit Please contact Norsat for cooling requirement specifications 3 3 Accessories Each ATOM unit ships wi...

Страница 26: ...dependent Configuration dependent 3 5 Standard Warranty Norsat International Incorporated warrants that its equipment shall be free from defects in material or workmanship for a period of one 1 year from the ship date unless otherwise stated in the Offer Terms and Conditions The warranty does not cover units that have been damaged through improper use or physical damage e g dropped units been modi...

Страница 27: ...CONFIDENTIAL AND PROPRIETARY Norsat International Incorporated Norsat All Rights Reserved 2021 02 16 INS001201 Rev B 27 Appendix A Mechanical Drawings Figure A 3 1 25W 40W Ka BUC SSPA Fan Cooled ...

Страница 28: ...CONFIDENTIAL AND PROPRIETARY Norsat International Incorporated Norsat All Rights Reserved 2021 02 16 INS001201 Rev B 28 Figure A 3 2 25W 40W Ka BUC SSPA Baseplate Cooled ...

Страница 29: ...CONFIDENTIAL AND PROPRIETARY Norsat International Incorporated Norsat All Rights Reserved 2021 02 16 INS001201 Rev B 29 Figure A 3 3 50W Ka BUC SSPA Fan Cooled ...

Страница 30: ...orsat International Incorporated Norsat All Rights Reserved 2021 02 16 INS001201 Rev B 30 Figure A 3 4 50W Ka BUC SSPA Baseplate Cooled Note 1 N Connector Input Shown For SSPA option the N Connector will be replaced with K Connector ...

Страница 31: ...s Acronym Definition BUC Block Upconverter AMP Amplifier C Celsius CR Carriage Return character ASCII dBm Decibel milliwatts DC Direct Current ESD Electrostatic Discharge freq Frequency GHz Gigahertz GND Ground IF Intermediate Frequency kHz kilohertz LF Line Feed character ASCII M C Monitor and Control MHz Megahertz mm Millimeter N A Not Applicable ppm Pulses per minute RF Radio Frequency RX Recei...

Страница 32: ...s military organizations health care providers and Fortune 1000 companies ABOUT NORSAT Norsat International Inc founded in 1977 is a leading provider of innovative communication solutions that enable the transmission of data audio and video for remote and challenging applications Norsat s products and services include customizable satellite components portable satellite terminals maritime solution...

Отзывы: