Figure 2-10: Setup Serial Port
2.5.1 Controller Responses
The unit will only generate messages in response to a command. Each command received will result in a
single message reply, which may simply be an Acknowledge message.
In general, command responses are returned immediately, though the precise command-response delay
varies slightly based on the specific command.
2.5.2 Message Definitions
getident
This command returns the part number, software revision and serial number of the unit.
Figure 2-11: Command getident
getstatus
This command instructs the unit to respond with fault flag, forward power and temperature. Note: reverse
power, “revpwr”, in the response is a future enhancement and is not currently supported.
•
A “0” after “fault” indicates no faults. A “1” indicates a fault. Use command “getfaults” to determine
what fault exists.