background image

PULSE 2.0 User Manual

11

• Atmospheric pressure (storage and transportation): 190hPa to 1060hPa
• Atmospheric pressure (operating): 700hPa to 1060hPa

AC-DC ADAPTER

WARNING! Only use the AC-DC adapter model number 30120 provided with the system. Using a different adapter may 

cause the system to not operate correctly.

• Input: 100-240V 

 0.8-0.4 A  50/60 Hz per NormaTec model number 30120

• Output: 15V 

 DC minimum 1.6 A per NormaTec model number 30120

ELECTROMAGNETIC COMPATIBILITY >>

The information contained in this section (such as separation distances) is in general specifically written with regard to the 
NormaTec PULSE 2.0. The numbers provided will not guarantee faultless operation but should provide reasonable assurance 
of such. This information may not be applicable to other medical electrical equipment; older equipment may be particularly 
susceptible to interference.

GENERAL NOTES

Medical electrical equipment requires special precautions regarding electromagnetic compatibility (EMC) and needs to 
be installed and put into service according to the EMC information provided in this document and the remainder of the 
instructions for use of this device.

Portable and mobile RF communications equipment can affect medical electrical equipment.

Cables and accessories not specified within the instructions for use are not authorized. Using other cables and/or accessories 
may adversely impact safety, performance, and electromagnetic compatibility (increased emission and decreased immunity).

Care should be taken if the equipment is used adjacent to or stacked with other equipment; if adjacent or stacked use is 
inevitable, the equipment should be observed to verify normal operation in the configuration in which it will be used.

ELECTROMAGNETIC EMISSIONS

This equipment is intended for use in the electromagnetic environment specified below. The user of this equipment should 
assure that it is used in such an environment.

EMISSIONS

COMPLIANCE 
ACCORDING TO

ELECTROMAGNETIC ENVIRONMENT

RF emissions 
(CISPR 11)

Group 1

The equipment uses RF energy only for its internal 
function. Therefore, its RF emissions are very low and are 
not likely to cause any interference in nearby electronic 
equipment. 

CISPR emissions classification

Class B

The equipment is suitable for use in all establishments, 
including domestic establishments and those directly 
connected to the public low-voltage power supply network 
that supplies buildings used for domestic purposes.

Harmonic emissions  
(IEC 61000-3-2)

Class A

Voltage fluctuations/flicker 
(IEC 61000-3-3)

Complies

Содержание PULSE 2.0

Страница 1: ...PULSE 2 0 UserManual 2 PULSE 2 0 UserManual ...

Страница 2: ...em Adjust the Intensity and Time Bluetooth Wireless Technology Start Pause and Stop the Session Turn Off the Device Use Zone Boost Adjust the Rest Time Massage Pattern and Number of Zones Caring for the System 9 Cleaning the System Maintaining the System Storing the System Additional Accessories and Replacement Parts Technical Information 10 Troubleshooting 15 Warranty Information 15 Return Policy...

Страница 3: ...ms hips or custom attachments since this may cause the system to operate incorrectly To avoid risk of strangulation do not leave a baby or child unattended with the power supply or hose Choking hazard small parts Keep away from small children Do not leave the system power supply or any accessories where they could be damaged by children pets pests or liquids If you suspect your device is damaged c...

Страница 4: ... water On base of device Read instructions before use On base of device and attachment tag Level of protection type BF equipment On base of device Double insulation On power adapter Direct current On base of device Alternating current In manual Manufacturer s name and address On base of device and attachment tag Date of manufacture On base of device Separate collection for waste electrical and ele...

Страница 5: ...e medical device itself In manual Tip to provide guidance to make use easier Risk to user is considered negligible In manual INDICATIONS FOR USE The NormaTec PULSE 2 0 Recovery System is an air pressure massager indicated to temporarily relieve minor muscle aches and or pains and to temporarily increase circulation to the treated areas RISKS AND BENEFITS OF THE NORMATEC RECOVERYSYSTEM The risks an...

Страница 6: ...crease 4 Time adjustment button increase 5 Pressure adjustment button increase 6 Pressure adjustment button decrease 7 Display screen 8 Zone Boost button 9 Play pause button NORMATEC HOSE single person use only 1 1 2 4 3 1 Junction box air outlets 2 Junction box 3 Blocking plug on the underside of the junction box 4 Connector LEG ATTACHMENT single person use only 1 2 1 Attachment connector 2 Zones...

Страница 7: ...ry The battery automatically charges when the power supply is connected to the PULSE 2 0 device and an electrical outlet Step 2 Connect the hose connector to the air outlet on the PULSE 2 0 device The connector can only be inserted in the correct orientation Insert the connector firmly into the PULSE 2 0 device until you hear an audible click Step 3 Put the leg arm or hip attachments on Find a com...

Страница 8: ...reen will display CONTINUOUS instead of the timer and will begin counting up from zero when the session starts Time can be adjusted while the session is running Tap the time adjustment buttons to add or subtract time from the session in 5 minute increments BLUETOOTH WIRELESS TECHNOLOGY The NormaTec Mobile App can connect your NormaTec device to a compatible smartphone via Bluetooth wireless techno...

Страница 9: ...one Zone Boost can only be enabled during a session Only one zone can be boosted at a time Zone Boost is only available with the patented NormaTec Pulse massage pattern Boosted zones will appear with the Zone Boost indicator on either side of the boosted zone figure 1 on the device s screen Activate Zone Boost When the zone you want to boost is flashing on the screen of the device tap the Zone Boo...

Страница 10: ...ne and five zones Zones can be disabled from the top to the bottom of the attachment one zone at a time Zone adjustments do not reset after powering off the device To enter zone edit mode set the device to Level 1 and then hold the level button for five seconds The top most enabled zone of the attachment will begin blinking When in zone edit mode the top enabled zone on the screen s attachment gra...

Страница 11: ...tion This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence...

Страница 12: ... RF communications equipment can affect medical electrical equipment Cables and accessories not specified within the instructions for use are not authorized Using other cables and or accessories may adversely impact safety performance and electromagnetic compatibility increased emission and decreased immunity Care should be taken if the equipment is used adjacent to or stacked with other equipment...

Страница 13: ...217 Hz 2450 Pulse Modulation 217 Hz 5240 5500 5785 Pulse Modulation 217 Hz 27 V m 28 V m 9 V m 28 V m 28 V m 28 V m 9 V m Equipment with high RF emissions should be kept at a distance to reduce the likelihood of interference Surges on AC mains lines IEC 61000 4 5 Common Mode 2 kV Differential Mode 1 kV 2 kV 1 kV Mains power quality should be that of a typical commercial or hospital environment Pow...

Страница 14: ...nded separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site surveya should be less than the compliance level in each frequency rangeb Interference may occur in the vicinity of equipment marked with the following symbol a The ISM industrial scientific and medical bands between 150 kHz and 80 MHz are 6 765 MHz to 6 795 MHz 13 553 MHz to 13...

Страница 15: ... applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer Note 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies Note 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures obje...

Страница 16: ...ranty NormaTec Attachments and Other Accessories Limited Two Year Warranty The NormaTec PULSE 2 0 device is warranted by NormaTec a Massachusetts corporation NormaTec against manufacturing defects in material and workmanship for a period of two years from the date of purchase from NormaTec In the event of any such defect occurring during the warranty period NormaTec will at its option a correct th...

Страница 17: ...likely event that you are not satisfied with your purchase you may return it within thirty 30 days of the purchase date If you purchase incorrectly sized attachments they may be exchanged within fourteen 14 days of the purchase date All returns and exchanges are subject to the conditions listed below Returns and exchanges must have a Return Merchandise Authorization RMA number Obtain an RMA number...

Страница 18: ...04302019 70 00003 Rev 1 480 Pleasant Street Suite A200 Watertown MA 02472 USA www NormaTecRecovery com 1 617 658 5800 NTRecovery NormaTecRecovery NTrecovery ...

Отзывы: