Clearance Requirements from Vent Terminations to Building Openings

US Installations¹

Canadian Installations²

A =

Clearance above grade, veranda, porch, deck or 

balcony

12 in (30 cm)

12 in (30 cm)

B =

Clearance to window or door that may be opened

4 feet (1.2 m) below or to side of opening; 

1 ft (30cm) above opening

6 in (15 cm) for appliances ≤ 10,000 

Btuh (3 kw), 12 in (30 cm) for 

appliances > 10,000 Btuh (3 kw) and 

≤ 100,000 Btuh (30 kw), 36 in (91 cm) 

for appliances > 100,000 Btuh (30 kw)

C =

Clearance to permanently closed window

*

*

D =

Vertical clearance to ventilated soffit located above 

the terminal within a horizontal distance of 

2 ft (610 cm) from the center line of the terminal

*

*

E =

Clearance to unventilated soffit

*

*

F =

Clearance to outside corner

*

*

G =

Clearance to inside corner

*

*

H =

Clearance to each side of center line extended above 

meter / regulator assembly

*

*

I =

Clearance to service regulator vent outlet

*

Above a regulator within 3 ft (91 cm)

horizontally of the vertical center line of 

the regulator vent outlet to a maximum 

vertical distance of 15 ft (4.5 m)

J =

Clearance to nonmechanical air supply inlet to 

building or the combustion air inlet to any other 

appliance

4 ft (1.2 m) below or to side of opening; 

1 ft (30 cm) above opening

6 in (15 cm) for appliances ≤ 10,000 Btuh 

(3 kw), 12 in (30 cm) for appliances 

> 10,000 Btuh (3 kw) and ≤ 100,000 Btuh 

(30 kw), 36 in (91 cm) for appliances 

> 100,000 Btuh (30 kw)

K =

Clearance to a mechanical air supply inlet

3 ft (91 cm) above if within 10 ft (3 m) 

horizontally

6 ft (1.83 m)

L =

Clearance above paved sidewalk or paved driveway 

located on public property

7ft (2.13 m)

7 ft (2.13 m) †

M =

Clearance under veranda, porch, deck or balcony

*

12 in (30 cm) ‡

¹ 

In accordance with the current ANSI Z223.1/NFPA 54 Natural Fuel Gas Code

² 

In accordance with the current CSA B149.1, Natural Gas and Propane Installation Code

† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.

‡  Permitted only if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor. Lennox recommends avoiding this 

   location if possible.

Clearance in accordance with local installation codes and the requirements of the gas supplier. Clearance to opposite wall is 24 in (60 cm).

Содержание VCK-NRCP-1

Страница 1: ...ortant that this manual all other documents included in this system be reviewed in their entirety before beginning any work Installation should be made in accordance with the regulations of the Authority Having Jurisdiction local code authorities and utility companies which pertain to this type of water heating equipment Important This installation manual includes information specific to outdoor w...

Страница 2: ...ing and Packing 1 Part Shape Qty 5 Vent Screen 1 6 Hexagon Head with Flange Tapping Screw M4 x12 Outdoor Vent Cap 4 7 Truss Head Tapping Screw M4 x16 Vent Screen 2 Instruction Manual 1 2 2 1 3 5 4 6 7 Included Outdoor Kit Outdoor Kit Components Outdoor Kit Dimension 5 2 133mm 17 3 440mm 28 6 728mm 16 1 410mm 16 1 410mm 32 7 832mm ...

Страница 3: ...n at risk Ensure that the installation location adheres to the information included in this manual Failure to do so could result in property damage serious personal injury or death Failure of heater or components due to incorrect operating conditions IS NOT covered by product warranty The water heater must be installed as described in these instructions Upright with the suppled outdoor enclosure i...

Страница 4: ...ponents connected to the water heater are suitable for potable water applications Do not use this water heater for space heating applications CAUTION The water heater must be installed level in order for the condensate to properly flow out the collection system CAUTION Installation Clearances Outdoor Installation Clearances Table 1 Minimum Clearances Installation Clearances from Non Combustibles R...

Страница 5: ...sealed painted etc to prevent deterioration Failure to follow these instructions could result in substantial property damage serious personal injury or death Prevent Combustion Air Contamination Do not install the outdoor water heater in locations that can allow contamination of fresh intake air Note See Table 2 to prevent combustion air contamination Front Clearance from Wall Clearance from Handr...

Страница 6: ...nd glues Beauty shops New building construction Calcium chloride used for thawing Refrigeration Antistatic fabric softeners used in clothes dryers Refrigeration repair shops Remodeling areas Sodium chloride used for water softening Chlorine type bleaches laundry detergents and cleaning solvents Photoprocessingplants Garages and workshops Adhesives used to fasten DAMAGE TO THE HEATER CAUSED BY EXPO...

Страница 7: ...ne of the regulator vent outlet to a maximum vertical distance of 15 ft 4 5 m J Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance 4 ft 1 2 m below or to side of opening 1 ft 30 cm above opening 6 in 15 cm for appliances 10 000 Btuh 3 kw 12 in 30 cm for appliances 10 000 Btuh 3 kw and 100 000 Btuh 30 kw 36 in 91 cm for appliances 100 000 Btuh...

Страница 8: ...pe in place 2 Insert the VCK Exhaust Adapter and secure the front 2 screws re use the 2 screws that were removed in Step 1 1 Remove the Existing Exhaust Adapter by removing the 4 screws and pulling up on the adapter Existing Exhaust Adapter Phillips VCK Exhaust Adapter Exhaust Pipe Stopper 3 Insert the Exhaust Pipe into the VCK Exhaust Adapter Exhaust Pipe ...

Страница 9: ...acking applied inside of the Outdoor Vent Cap 7 Insert the Vent Screen into the Exhaust Pipe and secure with 2 screws Truss Head Tap ping Screw M4 x16 to the Outdoor Vent Cap Vent Screen 6 Use a Phillips screwdriver to tighten the 4 screws Hexagon Head with Flange Tapping Screw M4 x12 to secure the Outdoor Vent Cap Detail Detail Outdoor Vent Cap Do not overtighten Use hand screwdrivers only CAUTIO...

Страница 10: ...ton clockwise until the display reads 14 od 3 Press the Dial Button so oFF is flashing Default setting is oFF and outdoor vent function is not activated 4 Turn the Dial Button clockwise so on is flashing This will active the Outdoor Vent function 8 Setting 5 Press the Dial Button to save the current setting mode and return back to Installer Mode ...

Страница 11: ... Number Outdoor Vent Cap w Plate and Packing NPK285 Hexagon Head with Flange Tapping Screw M4 x12 Exhaust Pipe Stopper NPA214 Vent Screen with Finishing NPF217 Exhaust Pipe NPF215 Truss Head Tapping Screw M4 x16 VCK Exhaust Adapter w P75 O ring and Packing NPF216 ...

Отзывы: