Reference Tools & Sample Calculations
The tables and samples below are for reference only. The professional sizing and installing the gas
line should always run the appropriate calculations before all installations.
CAUTION
Which Table to Use
•
For NG installations with the initial supply pressure at point of delivery (at the meter, for example) is
less than 8” WC, use the 0.5” WC pressure drop table (Table 1).
•
For NG installations with the initial supply pressure at point of delivery is greater than or equal to 8”
WC, use the 3.0” pressure drop table (Table 2).
•
For all LP installation use (Table 3)
The inlet pressure must be at least 5” WC for NG or 8” WC for LP for all appliances in the gas system.
If the inlet gas pressure drops below 5” WC for NG or 8” WC for LP, the heater may continue to operate,
but the other appliances in the house may experience
flame
loss or ignition failure, which can result in
gas leakage into the home. Refer to the NFPA 54 for details.
Please contact Noritz for details. For corrugated stainless steel tubing (CSST) capacity tables, please
consult with the manufacturer.
Pipe
Size
Length (including fittings)
10'
20'
30'
40'
50'
60'
70'
80'
90'
100'
125'
(3m)
(6m)
(9m)
(12m)
(15m)
(18m)
(21m)
(24m)
(27m)
(30m)
(38m)
3/4"
360
247
199
170
151
137
126
117
110
104
92
1"
678
466
374
320
284
257
237
220
207
195
173
1 1/4"
1,390
957
768
657
583
528
486
452
424
400
355
1 1/2"
2,090
1,430
1,150
985
873
791
728
677
635
600
532
2"
4,020
2,760
2,220
1,900
1,680
1,520
1,400
1,300
1,220
1,160
1,020
2 1/2"
6,400
4,400
4,400
3,020
2,680
2,430
2,230
2,080
1,950
1,840
1,630
3"
11,300
7,780
7,780
5,350
4,740
4,290
3,950
3,760
3,450
3,260
2,890
4"
23,100 15,900 12,700 10,900
9,660
8,760
8,050
7,490
7,030
6,640
5,890
Table 1. For Less than 8” WC initial supply pressure
Maximum Natural Gas Delivery Capacity (0.5” Pressure Drop)
Values in Table are in Cubic Feet of Gas per Hour (0.60 Speci
fic
Gravity, 0.5” Pressure Drop, inlet pressure less than 2psi). Contact your gas
supplier for BTU/Cubic Foot ratings. For simpli
ficat
ion of your calculations, 1 Cubic Foot of Gas is approximately equivalent to 1000 BTU.
Instructions
1. Size each outlet branch starting from the furthest
using the Btuh required and the length from the meter.
2. Size each section of the main line using the length to
the furthest outlet and the Btuh required by everything
after that section.
Sample Gas Line
Sample Calculation - (Using 0.5” WC Pressure Drop Table)
Outlet A: 45' (13.5m) (Use 50' (15m)), 50,000 Btuh requires 1/2"
Outlet B: 40' (12m), 65,000 Btuh requires 1/2"
Section 1: 45' (13.5m) (Use 50' (15m)), 115,000 Btuh requires 3/4"
Outlet C: 30' (9m), 35,000 Btuh requires 1/2"
Section 2: 45' (13.5m) (Use 50' (15m)), 150,000 Btuh requires 3/4"
Outlet D: 25' (7.5m) (Use 30' (9m)), 25,000 Btuh requires 1/2"
Section 3: 45' (13.5m) (Use 50' (15m)), 175,000 Btuh requires 1"
Outlet E: 25' (7.5m) (Use 30' (9m)), 120,000 Btuh requires 3/4"
Section 4: 45' (13.5m) (Use 50' (15m)), 295,000 Btuh requires 1 1/4"
Natural Gas
Meter
Noritz Condensing Tankless Gas Water Heater
(120,000 Btuh)
Clothes Dryer
(35,000 Btuh)
Barbecue
(50,000 Btuh)
Gas Range Stove
(65,000 Btuh)
10' (3m)
10' (3m)
10' (3m)
10' (3m)
5' (1.5m)
5' (1.5m)
5' (1.5m)
5' (1.5m)
5' (1.5m)
5' (1.5m)
Gas Fireplace
(25,000 Btuh)
Section 3 Section 2
Section 1
Outlet A
Outlet B
Outlet C
Outlet D
Outlet E
Section 4
65
Содержание NRC661-DV
Страница 17: ...NR501 OD NR662 OD Thermistor Cold Water Thermistor Hot Water Gas Proportioning Valve 17...
Страница 19: ...19 5 Operation Flow Chart Water heating Shutdown procedure Ignition operation NR501 OD...
Страница 20: ...Water heating Shutdown procedure Ignition operation 20 NR662 OD...
Страница 70: ...the Heat Exchanger must be flushed is set to Flushing Mode from an authorized Noritz wholesaler 70...
Страница 71: ...located 71...