Maintenance Monitor List
Data
No.
Item
Unit
Minimum
Value for
Indication
Multiplier
Data
(Display Reading X Multiplier)
02
03
04
05
07
08
10
11
12
14
18
19
20
30
31
32
36
38
39
47
48
49
50
51
52
60
87
88
89
91
92
93
94
95
96
97
98
Position of
Output
FF+FB No.
FF No.
Output (%)
Total Flow Rate
Number of Ignition Times
Total Combustion Time
Total Plug-in Time
Fan Rotational Frequency
Calculated Fan Speed
Condensate Container clogging
Thermistor - Heat Exchanger
Detection Temperature
Thermistor - Air
Detection Temperature
Fan Motor Current Value
Initial Fan Speed Correction
Final Fan Speed Correction
Circuit Board ID1: Product 1
Circuit Board ID2: Product 2
Circuit Board ID3: Version
Error Code History 1
Thermistor - Exhaust
Detection Temperature
Error Code History 3
Error Code History 4
Error Code History 5
Error Code History 6
Error Code History 7
Error Code History 8
Error Code History 2
Gas quality judging result
Total Combustion Time
Number of Ignition Times
Thermistor - Cold Water
Detection Temperature
Thermistor - Hot Water
Detection Temperature
Simple Self-diagnosis Counter
L/min
X 10000
X 10
Step
X 0.1
%
X 1
gal/min
X 10
time
hour
rpm
X 100
X 1000
X 1
X 1000
X 10
X 10
°F
mA
[1:xy]
[2:xy]
[3:xy]
[0:xx]
°C
X 0.1
X 1
X 0.1
X 0.1
X 0.1
X 1
X 1
X 1
X 1
X 1
X 1
X 1
X 1
X 10
0.1
X 0.1
X 0.1
[000] - [036]
[100] - [110]
[100] - [110]
Disp. Range [014] - [050]
Disp. Range [-10] - [010]
,Z=126
A=101,B=102,C=103,
,Z=226
A=201,B=202,C=203,
,Z=326
A=301,B=302,C=303,
If the same error code is repeated, it will appear
in the history list twice.
If it is repeated more than twice, it will only appear
twice.
*2, 3
*4
*1
OFF [000] , ON [001]
Disp. Range [000] - [65]
Disp. Range [000] - [999]
Disp. Range [000] - [65]
Disp. Range [000] - [999]
Disp. Range [000] - [999]
Disp. Range [000] - [999]
Disp. Range [000] - [65]
hour
hour
time
time
time
%
%
rpm
°F
°F
°F
°F
°C
°C
°C
°C
1°F
0.5°C
1°F
1°F
0.5°C
1°C
1°C
10mA
1%
1%
0.1
0.1
*1 A difference in the calculated (#20) and the measured (#10) fan speeds of ±500rpm or less is normal.
*2 When there is no Remote Controller (Using Display Window)
*3 When Remote Controller is in °F/Gallons mode.
*4 When Remote Controller is in °C/Liters mode.
X 0.1
100 hour
1 hour
1000 hour
10 times
10000 times
25 rpm
1 hour
1000 hour
0.1 gal/min
0.1L/min
1 %
25 rpm
1°F
0.5°C
1°F
Disp. Range [000] - [1310]
mA
X 1
1mA
Disp. Range [000] - [999]
Disp. Range [000] - [1999]
10Step
X 2
Step
2Step
*2
*3, 4
*2
*3, 4
*2
*3, 4
*2, 3
*4
*2, 3
*4
*2, 3
*4
*2, 3
*4
*2, 3
*4
29
---
---
---
Reason why the unit
does not run.
[001] : Water inlet temperature is too high
→
If possible decrease water inlet temperature
[002] : Calculated water outlet temperature is too high
→
If possible increase flow rate
[004] : Inlet and Outlet temperature are reversed
→
Check the pipes and re-install it correctly
---
---
---
60
Содержание NRC661-DV
Страница 17: ...NR501 OD NR662 OD Thermistor Cold Water Thermistor Hot Water Gas Proportioning Valve 17...
Страница 19: ...19 5 Operation Flow Chart Water heating Shutdown procedure Ignition operation NR501 OD...
Страница 20: ...Water heating Shutdown procedure Ignition operation 20 NR662 OD...
Страница 70: ...the Heat Exchanger must be flushed is set to Flushing Mode from an authorized Noritz wholesaler 70...
Страница 71: ...located 71...