Noritz N-084 Скачать руководство пользователя страница 4

6

7

Do not disassemble the remote controller.

This may cause damage to the heater or
unexpected accidents.

Do not use benzene, oil or fat detergents
to clean the remote controller.

This may cause deformation.

Do not get the remote controller wet.

Although it is waterproof, too much water can
cause damage.

Do not splash water on the remote
controller. Do not expose the remote
controller to steam.

Do not locate the remote controller near stoves or
ovens, this may cause damage or failure.

Take measures to prevent the unit from
freezing. (

p.17)

If water is allowed to freeze inside the unit, the unit
may be damaged, and water can leak out of it.

Take necessary measures to prevent
freezing of water and leakage of gas when
leaving the unit unused for long periods of
time. (

p.18)

If it is snowing, check the air inlet, exhaust
gas vent and exhaust vent terminal for
blockage.

This can result in improper function or damage to
the unit.

Do not use parts other than those specified
for this equipment.

Do not drink water that was inside the unit
for an extended period of time, do not
drink the water that comes out of the unit
just after the first use of hot water in the
morning.

Use it for other purposes.

Clean the filter on the water inlet.

If you don’t know where the filter is, contact the
nearest Noritz agent.

Keep the area around the unit clean.

If boxes, weeds, cobwebs, cockroaches etc. are
allowed to be in the vicinity of the unit, damage or
fire can result.

Do not install the equipment where the
exhaust will blow on walls or windows.

This may cause damage or discoloration.

Do not use spring water or well water.

This can cause damage and reduce durability.

Check for proper combustion during
operation and that the flame stops after
operation is finished.

To prevent accidents due to gas.

Be sure to electrically ground the
unit.

Do not touch the power cord with
wet hands.

Keep power cord free of dust.

This can cause a fire.

Do not use a broken or modified
power cord.  Do not bind, bend or
stretch power cords.

Do not place things on them,
scratch.  Do not scratch, modify or
subject them to impact or force.

Do not use the water heater for
other than hot water supply,
shower and bath.

To prevent unexpected accidents.

Do not touch the exhaust vent pipe
during or immediately after
operation of the water heater.

Do not connect the water heater to
a solar water heater.

This can result in unreliable temperature
control, scalding or equipment failure.

Do not use hair spray or spray
detergent in the vicinity of the
heater.

These may cause damage to the heater.

    Caution

Remark

IMPORTANT SAFETY INFORMATION

 -3

Содержание N-084

Страница 1: ...tly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WH...

Страница 2: ...appliance 2 Do not touch any electrical switch do not use any phone in your building 3 Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions 4 If you cannot...

Страница 3: ...s on the rating plate Using an improper gas or electric supply may cause improper operation fire or electric shock Do not allow small children to play unsupervised in the bathroom Do not allow small c...

Страница 4: ...lean the filter on the water inlet If you don t know where the filter is contact the nearest Noritz agent Keep the area around the unit clean If boxes weeds cobwebs cockroaches etc are allowed to be i...

Страница 5: ...d 15 Setting button Before use remove the protective sheet from the remote controller surface Name and Functions of Components Indoor wall mounted power vented model The above illustration shows an ex...

Страница 6: ...fixture again 3 Fully open the gas valve Hot water fixture Follow steps 1 through 4 2 Water temperature Ex 104 F Water level The display will flash p 15 Failure indicator When this indicator lights t...

Страница 7: ...while hot water is running Flash for 10 sec light up 4 3 Run hot water 2 Adjust temperature Check the indicator lights Hot Cold Water temperature If the remote controller was left set at 167 F the la...

Страница 8: ...The setting is remembered Water level will be flashing ex 45 gal The level can be adjusted while the indicator is flashing The temperature will return after ten seconds Set the water level of your tu...

Страница 9: ...with insulation or an electric heater If you are still worried that your heater will freeze contact the nearest Noritz agent When the temperature drops the freeze prevention heaters are automatically...

Страница 10: ...s method cannot prevent the water supply hot water piping and water supply valve from freezing Be sure to protect them with insulation or an electric heater If you are still worried the unit will free...

Страница 11: ...ened Are the gas and water supply valves fully open Is the water supply cut off Is the hot water fixture sufficiently open Is the heater frozen Is the gas meter working For LP Is there enough gas in t...

Страница 12: ...y may become unstable when the remote controller is cleaned with a dry cloth Leave it for 30 minutes and it will return to normal Other The Heater stops burning during operation Are the gas and water...

Страница 13: ...d repairable Follow up service Requesting service Minimum period of time for stocking repair parts Noritz will stock repair parts for this unit for a minimum of seven years after production has ceased...

Страница 14: ...mum Performance 21 000 btuh 21 000 btuh Specification N 084 Indoor or Outdoor Wall Hanging Power Vented Direct Ignition 15 150 PSI 0 75 GPM 24 2 Height x 18 3 Width x 9 4 Depth XXX lbs 0 3 Gallon 3 4...

Страница 15: ...11 Case top packing EDM EDML001 1 1 1 1 1 1 1 1 1 1 1 012 Exhaust connection packing DHN DHNL003 DEKA017 CRUK002 BUBK004 Terminal block mounting plate DHN 027 028 Conduit 92 120V EAU 029 Lamp seal pla...

Страница 16: ...EDME006 1 SAB1512 2 SAQ7708 1 8590109 1 EAUE001 1 DLTC001 1 CRPC052 1 CRUC045 1 CRUC046 1 EAUE005 1 Combustion tube SET DHN SET AS Plug packing Q CRU Burner sensor CRU A SET V Ignition plug CRU SET V...

Страница 17: ...ve heater 3 BGD O ring P22 O ring P22C Hot water outlet pipe DHN Bypass pipe DHN Hot water outlet thermostat 300 BWC SET V Water level sensor SET3 DHN SET V Water inlet thermostat 300 BWC SET V O ring...

Страница 18: ...Nylon clamp HP 4N NK 4N Nylon clamp HP 2N NK 2N Gas type change connector 1 CRU Gas type change connector 2 CRU Switch cover CYD 700 701 702 703 704 706 707 708 710 705 712 713 714 715 716 F point th...

Страница 19: ...llation Guide upon completion of the installation work Please put your information on the warranty card in the operation manual and give it to the customer when installation is completed Requests to i...

Страница 20: ...as those where gasoline benzene and adhesives are handled or places in which corrosive gases ammonia chlorine sulfur ethylene compounds acids are present Installation in an improper location may caus...

Страница 21: ...pace in front so as to facilitate inspection and repair of the equipment Leave sufficient distance when installing the water heater around permanent gas cooking equipment which can produce steam conta...

Страница 22: ...an be damaged and cause a danger of accident Be sure to mount the water heater on an upright wall Securing to the wall Mounting Water heater and building structure Mounting board upper Location of scr...

Страница 23: ...ystem by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa The appliance and its gas conn...

Страница 24: ...r a local plumbing inspector on how to control this situation A pressure relief valve must be installed near the hot water outlet that is rated in accordance with and complying with either The Standar...

Страница 25: ...eater in the water heater Tie the redundant cord outside the water heater Do not put the extra length inside the equipment Keep the remote controller cord length below 100 meters Use a Y type terminal...

Страница 26: ...valve Make sure to drain the water unless the unit will be used immediately This is to prevent the water from freezing and the water heater from being damaged Follow the instructions in the Owner s M...

Страница 27: ...Y PASS OPTIONAL RESISTOR GND Fully close SM LS Vcc V Vcc SM W W W W WW WW W W W W W W W W W O W W W W O O W W W W W W W W W O G V Y R R BK O G BK BR O G V BK BR BL Y BL O G V BK BK BR Y R BL Y R R BR...

Страница 28: ...entive packing Stay pipe Cap nut Connecting electric cord Wind the redundant cord here Connecting electric cord Outdoor cover Cap nut Take off the released paper For in wall wiring 1 Put the remote co...

Страница 29: ...n 0 98 Max 2 3 inches Inlet Gas Pressure Min 3 5 Max 10 5 inches Recovery Rate 313 Gallons Hour BTU Input Max 236 000 Min 21 000 Model N 084 Tel 949 420 0409 20492 Crescent Bay Dr Ste 104 Lake Forest...

Страница 30: ...58...

Отзывы: