Noritz N-084 Скачать руководство пользователя страница 26

50

51

(unit: inch)

Dimensional outline drawing

 N-084

3.4

6.1

0.4

24.2

2

1.7

9.4

6.7

9.8

2.8

14.2

7.3

2.4

2.8

3.9

5.5

6.7

17.7

26.2

1.6

0.4

3.7

18.3

8.85

17.7

5.5

6.7

φ  

4

2.7

0.9

23

2.8

GAS INLET

ELE. WIRE OUTLET

ELE. WIRE OUTLET

COLD WATER INLET 3/4 in. NPT

HOT WATER OUTLET 3/4 in. NPT

PRESSURE RELIEF VALVE

GAS INLET 3/4 in. NPT

HOT WATER OUTLET

COLD WATER INLET

WATER DRAIN VALVE

10-

φ

0.3HOLE

EXHAUST PIPE FITTING PART

AIR INLET

5-

φ

0.3HOLE

HOLE FOR APPLIANCE INSTALLATION

(FROM TOP SIDE VIEW)

BOTTOM OF CASE

HOLE FOR APPLIANCE INSTALLATION

1.4

(1) Open the hot water supply valve, and check that the combustion indicator comes on, and that hot

water is provided. (If necessary, repeat until the air in the gas piping is bled out).

* If error "11" is indicated, turn the Operation switch off and turn it on again, and open the hot water

plug once more.

(2) Adjust the temperature setting on the remote control and confirm that the water temperature changes.

If the water heater does not operate normally, refer to "Troubleshooting" in the Operation Manual.

* After the trial operation, clean the filter on the inlet.

10.

Trial operation

After installation, test the equipment to confirm the
water heater works properly.

 Handling after trial operation

Drain the water for freeze prevention, and close the gas valve and water supply valve.
Make sure to drain the water, unless the unit will be used immediately. This is to prevent the
water from freezing and the water heater from being damaged. Follow the instructions in the
Owner’s Manual.
(Freezing is not covered by the warranty.)

Preparation ........... (1) Open the shut off valve on the water supply, check that water passes through

the valve and close the valve.

(2) Open the gas supply valve, turn on the power supply, and turn on the Opera-

tion switch on the remote controller (the Operation lamp turns on).

Caution

Lighting Instructions

This water heater does not have a pilot.  It is equipped with an ignition device that automatically lights
the burner.
Do not try to light the burner by hand.
1. Read the safety information in the installation manual or on the front of the water heater.
2. Turn off all electrical power to the unit.
3. Do not attempt to light the burner by hand.
4. Turn the gas control manual valve (external to the unit) clockwise to the on position.
5. Wait five minutes to clear out any gas.  If the smell of gas remains, stop, and follow the instructions on

page 2 of this manual.

6. Turn the gas control manual valve counterclockwise to the on position.
7. Turn on electric power to the unit.
8. The unit will now operate whenever hot water is called for.  If the unit will not operate, follow the

shutdown instructions and call a service technician.

Shutdown Instructions

1. Stop any water demand.
2. Turn off electric power.
3. Turn the gas control manual valve clockwise to the off position.

Содержание N-084

Страница 1: ...tly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WH...

Страница 2: ...appliance 2 Do not touch any electrical switch do not use any phone in your building 3 Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions 4 If you cannot...

Страница 3: ...s on the rating plate Using an improper gas or electric supply may cause improper operation fire or electric shock Do not allow small children to play unsupervised in the bathroom Do not allow small c...

Страница 4: ...lean the filter on the water inlet If you don t know where the filter is contact the nearest Noritz agent Keep the area around the unit clean If boxes weeds cobwebs cockroaches etc are allowed to be i...

Страница 5: ...d 15 Setting button Before use remove the protective sheet from the remote controller surface Name and Functions of Components Indoor wall mounted power vented model The above illustration shows an ex...

Страница 6: ...fixture again 3 Fully open the gas valve Hot water fixture Follow steps 1 through 4 2 Water temperature Ex 104 F Water level The display will flash p 15 Failure indicator When this indicator lights t...

Страница 7: ...while hot water is running Flash for 10 sec light up 4 3 Run hot water 2 Adjust temperature Check the indicator lights Hot Cold Water temperature If the remote controller was left set at 167 F the la...

Страница 8: ...The setting is remembered Water level will be flashing ex 45 gal The level can be adjusted while the indicator is flashing The temperature will return after ten seconds Set the water level of your tu...

Страница 9: ...with insulation or an electric heater If you are still worried that your heater will freeze contact the nearest Noritz agent When the temperature drops the freeze prevention heaters are automatically...

Страница 10: ...s method cannot prevent the water supply hot water piping and water supply valve from freezing Be sure to protect them with insulation or an electric heater If you are still worried the unit will free...

Страница 11: ...ened Are the gas and water supply valves fully open Is the water supply cut off Is the hot water fixture sufficiently open Is the heater frozen Is the gas meter working For LP Is there enough gas in t...

Страница 12: ...y may become unstable when the remote controller is cleaned with a dry cloth Leave it for 30 minutes and it will return to normal Other The Heater stops burning during operation Are the gas and water...

Страница 13: ...d repairable Follow up service Requesting service Minimum period of time for stocking repair parts Noritz will stock repair parts for this unit for a minimum of seven years after production has ceased...

Страница 14: ...mum Performance 21 000 btuh 21 000 btuh Specification N 084 Indoor or Outdoor Wall Hanging Power Vented Direct Ignition 15 150 PSI 0 75 GPM 24 2 Height x 18 3 Width x 9 4 Depth XXX lbs 0 3 Gallon 3 4...

Страница 15: ...11 Case top packing EDM EDML001 1 1 1 1 1 1 1 1 1 1 1 012 Exhaust connection packing DHN DHNL003 DEKA017 CRUK002 BUBK004 Terminal block mounting plate DHN 027 028 Conduit 92 120V EAU 029 Lamp seal pla...

Страница 16: ...EDME006 1 SAB1512 2 SAQ7708 1 8590109 1 EAUE001 1 DLTC001 1 CRPC052 1 CRUC045 1 CRUC046 1 EAUE005 1 Combustion tube SET DHN SET AS Plug packing Q CRU Burner sensor CRU A SET V Ignition plug CRU SET V...

Страница 17: ...ve heater 3 BGD O ring P22 O ring P22C Hot water outlet pipe DHN Bypass pipe DHN Hot water outlet thermostat 300 BWC SET V Water level sensor SET3 DHN SET V Water inlet thermostat 300 BWC SET V O ring...

Страница 18: ...Nylon clamp HP 4N NK 4N Nylon clamp HP 2N NK 2N Gas type change connector 1 CRU Gas type change connector 2 CRU Switch cover CYD 700 701 702 703 704 706 707 708 710 705 712 713 714 715 716 F point th...

Страница 19: ...llation Guide upon completion of the installation work Please put your information on the warranty card in the operation manual and give it to the customer when installation is completed Requests to i...

Страница 20: ...as those where gasoline benzene and adhesives are handled or places in which corrosive gases ammonia chlorine sulfur ethylene compounds acids are present Installation in an improper location may caus...

Страница 21: ...pace in front so as to facilitate inspection and repair of the equipment Leave sufficient distance when installing the water heater around permanent gas cooking equipment which can produce steam conta...

Страница 22: ...an be damaged and cause a danger of accident Be sure to mount the water heater on an upright wall Securing to the wall Mounting Water heater and building structure Mounting board upper Location of scr...

Страница 23: ...ystem by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa The appliance and its gas conn...

Страница 24: ...r a local plumbing inspector on how to control this situation A pressure relief valve must be installed near the hot water outlet that is rated in accordance with and complying with either The Standar...

Страница 25: ...eater in the water heater Tie the redundant cord outside the water heater Do not put the extra length inside the equipment Keep the remote controller cord length below 100 meters Use a Y type terminal...

Страница 26: ...valve Make sure to drain the water unless the unit will be used immediately This is to prevent the water from freezing and the water heater from being damaged Follow the instructions in the Owner s M...

Страница 27: ...Y PASS OPTIONAL RESISTOR GND Fully close SM LS Vcc V Vcc SM W W W W WW WW W W W W W W W W W O W W W W O O W W W W W W W W W O G V Y R R BK O G BK BR O G V BK BR BL Y BL O G V BK BK BR Y R BL Y R R BR...

Страница 28: ...entive packing Stay pipe Cap nut Connecting electric cord Wind the redundant cord here Connecting electric cord Outdoor cover Cap nut Take off the released paper For in wall wiring 1 Put the remote co...

Страница 29: ...n 0 98 Max 2 3 inches Inlet Gas Pressure Min 3 5 Max 10 5 inches Recovery Rate 313 Gallons Hour BTU Input Max 236 000 Min 21 000 Model N 084 Tel 949 420 0409 20492 Crescent Bay Dr Ste 104 Lake Forest...

Страница 30: ...58...

Отзывы: