Noritz N-084 Скачать руководство пользователя страница 27

52

53

Notes on the place of installation

The remote controller can be installed at a
convenient place in the bathroom, because
it is waterproofed and of a low-voltage de-
sign, but should avoid the place where wa-
ter may splash on the controller.

Avoid the place where special chemical
agents (e.g., benzine, fatty and oily deter-
gents) are used.

Avoid outdoor installation, and an indoor
place where the remote controller is ex-
posed in direct sunlight.

Supplied Parts List

Remote Controller RC-7646M

Installation Guide

Request to Constructors

Read this installation guide
carefully before carrying out
the construction specified.

NORITZ AMERICA CORPORATION

Note

Do not insert the power plug of the water heater into the outlet until the installation of the remote
controller is completed.

Do not disassemble the remote controller.

Wall packing

Connecting electric cord

Remote controller

Phillips roundhead
wood screw

Confirmation of remote controller cord

2P connector

Remote controller side

Y-shaped terminal

Water heater side

(two-core)

Confirm the connection with the labels at the
both ends of the remote controller cord.

The following remote controller cords are
provided for the selection of a necessary
length of cord according to the installation
condition:

3A (3m), 5A (5m), 8A (8m), 10A (10m),
15A (15m), 20A (20m), 50A (50m)

Wall plug

SV

10

0

13

14

Q4

SV

Q3

SV

12

Q2

SV

+

-

DU

11

SV

Q1

50

FM

IG

46

QS

QS

B5

EDMK001

WATER THERMISTOR
FOR HEAT
EXCHANGER

TRANSFORMER

COLOR CODING

<AC120V>

FLAME ROD

W  : White

BL : Blue

Y   : Yellow

BR : Brown

G   : Green

GY : Gray

O   : Orange

V   : Violet

BK : Black

R   : Red

FROST SENSING
SWITCH

WATER OUTLET
THERMISTOR

REMOTE CONTROLLER
RC-7646M

<CN100>

GROUND

CURRENT
LEAKAGE
SAFETY DEVICE

GROUND

<CN92>

WATER VALVE

(OPTIONAL)

FAN MOTOR

<CN103>

<CN102>

<CN27>

POWER CIRCUIT
BOARD

ANTI-FROST HEATER

ELECTRODE

HIGH-LIMIT SWITCH

Push Button(High Capacity)

Push Button(Low Capacity)

Secondary Gas Pressure Adjustment Volume(High Capacity)

Secondary Gas Pressure Adjustment Volume(Low Capacity)

WATER FLOW
CONTROL DEVICE
FOR HEAT
EXCHANGER

(GND)

LS

SYSTEM CONTROLLER
SC-101-3M-B
SC-101-6M-B

WATER FLOW
SENSOR FOR HEAT
EXCHANGER

WATER INLET
THERMISTOR

AIR INLET
THERMISTOR

WATER FLOW
SENSOR FOR
BY-PASS

(GND)

(Vcc)

(Pulse)

(GND)

(Vcc)

(Pulse)

WATER FLOW
CONTROL DEVICE
FOR BY-PASS

(OPTIONAL)

RESISTOR

(GND)

(Fully close)

SM

LS

(Vcc)

V

(Vcc)

SM

W

W

W

W

W W

W W

W
W
W

W

W

W

W

W

W

O

W
W

W
W

O
O

W

W

W

W

W
W

W
W

W

O
G
V

Y

R

R

BK

O
G

BK

BR

O
G
V

BK

BR

BL

Y
BL

O
G
V

BK

BK

BR

Y

R

BL

Y

R

R

BR

BL

W

BL

BL

W

W

W

Y

R

W
W

W

Y

BL

R

R

Y

BL

R

Y

BL

R

Y

BL

R

Y

BL

(Vcc)

(Vcc)

<CN102>

<CN78>

<CN89>

<CN73>

<CN50>

MAIN CIRCUIT
BOARD

<CN1>

<CN38>

<CN75>

GAS VALVE UNIT

BURNER THRMISTOR

THERMAL FUSE

(Fully close)

B

A

WATER OUTLET THERMISTOR

WATER THERMISTOR
FOR HEAT EXCHANGER

BURNER THERMISTOR

AIR INLET THERMISTOR

WATER INLET THERMISTOR

INPUT AND
OUTPUT PULSE

GAS PROPORTION VALVE
POWER CONTROL CIRCUIT

FLAME DETECTING CIRCUIT

FLAME ROD

FR

DU

GND

RELAY 9

FROST SENCING SWITCH

THERMAL FUSE

RELAY 5

RELAY 8

RELAY 1

RELAY 2

WATER FLOW SERVO 2

WATER FLOW SENSOR 2

WATER FLOW SERVO 1

WATER FLOW SENSOR 1

15V POWER CIRCUIT

CENTRAL
PROCESSING 
UNIT

RELAY
DRIVING
CIRCUIT

CPU

5V POWER CIRCUIT

FAN
PULSE
CONTROL 
CIRCUIT

C

DC140V

ANTI-FROST HEATER

10A(FUSE)

POWER 
CONTROLLER

DC15V(2)

DC15V(1)

PRIMARY

SECONDARY

DC90V

RELAY 2

RELAY 5

RELAY 4

RELAY 1

A

B

C

SOLENOID VALVE 3

SOLENOID VALVE 4

SOLENOID VALVE 2

SOLENOID VALVE 1

FAN

SV3

SV4

SV2

SV1

COMBUTION FAN

DC90V

VARISTOR

RELAY 3

RELAY 9

RELAY 8

HOT

SOLENOID VALVE 0

IGNITER

IG

SV0

AC100V

SECONDARY

PRIMARY

AC120V

GND

DC140V

HIGH LIMIT
SWITCH

ARRESTER VARISTOR

NEUTRAL

<CN70>

NG

LPG

GAS TYPE SWITCHING
CONECTOR

BURNING LED

WIRING DIAGRAM (MODEL :N-084)

(Fully open)

(Fully open)

1
2
3
4
5
6
7

4
3
2
1

3
2
1

3
2
1

8
9

10

1
2

2
1

2
1

3
4
5
6
7
8
9

10

1
3
5
7
9

11
13
15
17
19

2
4
6
8

10
12
14
16
18
20

21 22

BL

BL

BK

BL

O
G
V
Y

BR

W

BK

R

O

O

W

BK

GY

W
W

BL
G
V
O
BK
W
Y
BR
W
R

1

1

BL

W

R

G

W

W

W

W
W
W

W

BL

1

3
5
7
9

11
13
15

8
7
6
5
4
3
2
1

O

W

R
Y
BK

3
2
1

BL

BL

3
2
1

G

G

G

W

WW

BK

BL

2
1

BK

R

2
1

4
2

3
1

6
5
4

W
W
W
W
W

W

7
6
5
4
3
2
1

7
6
5
4
3
2
1

GY
BK

BK

W
W
W

W

W

BL
BR

BL

R
O

GY

BK

BK

GY

BR

W

G

W

BL
BR

BL
R
O

GY

GY
BK

W,BK,GY
W,BK,GY

W,BK,GY
W,BK,GY

W,BK,GY

W

1
2

1
2

3
4
5
6

8
7
6
5
4
3
2
1

BK

W

BK

W

1
2

7
6
5
4
3
2
1

7
6
5
4
3
2
1

O

W

R

BL

Y O

Y

W

7
6

6 5 4 3 2 1

W

W

W

WW

G

W

GY

BR

BK

BK

BL

7 8 9 10 11 12

1 2 3 4 5 6

5
4
3
2
1

5
4
3
2
1

17
19

2
4
6
8

10
12
14
16
18
20

6
5
4
3
2
1

4
3
2
1

3
2
1

2
1

W
W

W
W

1
2

W
W

W
W

1
2

W
W

W
W

1
2

W
W

W
W

1
2

W
W

W
W

1
2

W
W

1
2

2
1

BL

BL

BK

W

BK
W

BL

BL
BL

2
1

1
2

BK

W

G

BK

W

3
2
1

BK

W

BK

W

3
2
1

W

BL

W
BL

1
2
3

W(Vs)

BL(GND)

R(Vcc)

O(Vsp)

Y(FG)

W

BL
R

O

Y

.

.

.

Part Name

Remote controller

Wall packing

Phillips roundhead wood screw

Wall plug

Quantity

1

1

2

2

Содержание N-084

Страница 1: ...tly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WH...

Страница 2: ...appliance 2 Do not touch any electrical switch do not use any phone in your building 3 Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions 4 If you cannot...

Страница 3: ...s on the rating plate Using an improper gas or electric supply may cause improper operation fire or electric shock Do not allow small children to play unsupervised in the bathroom Do not allow small c...

Страница 4: ...lean the filter on the water inlet If you don t know where the filter is contact the nearest Noritz agent Keep the area around the unit clean If boxes weeds cobwebs cockroaches etc are allowed to be i...

Страница 5: ...d 15 Setting button Before use remove the protective sheet from the remote controller surface Name and Functions of Components Indoor wall mounted power vented model The above illustration shows an ex...

Страница 6: ...fixture again 3 Fully open the gas valve Hot water fixture Follow steps 1 through 4 2 Water temperature Ex 104 F Water level The display will flash p 15 Failure indicator When this indicator lights t...

Страница 7: ...while hot water is running Flash for 10 sec light up 4 3 Run hot water 2 Adjust temperature Check the indicator lights Hot Cold Water temperature If the remote controller was left set at 167 F the la...

Страница 8: ...The setting is remembered Water level will be flashing ex 45 gal The level can be adjusted while the indicator is flashing The temperature will return after ten seconds Set the water level of your tu...

Страница 9: ...with insulation or an electric heater If you are still worried that your heater will freeze contact the nearest Noritz agent When the temperature drops the freeze prevention heaters are automatically...

Страница 10: ...s method cannot prevent the water supply hot water piping and water supply valve from freezing Be sure to protect them with insulation or an electric heater If you are still worried the unit will free...

Страница 11: ...ened Are the gas and water supply valves fully open Is the water supply cut off Is the hot water fixture sufficiently open Is the heater frozen Is the gas meter working For LP Is there enough gas in t...

Страница 12: ...y may become unstable when the remote controller is cleaned with a dry cloth Leave it for 30 minutes and it will return to normal Other The Heater stops burning during operation Are the gas and water...

Страница 13: ...d repairable Follow up service Requesting service Minimum period of time for stocking repair parts Noritz will stock repair parts for this unit for a minimum of seven years after production has ceased...

Страница 14: ...mum Performance 21 000 btuh 21 000 btuh Specification N 084 Indoor or Outdoor Wall Hanging Power Vented Direct Ignition 15 150 PSI 0 75 GPM 24 2 Height x 18 3 Width x 9 4 Depth XXX lbs 0 3 Gallon 3 4...

Страница 15: ...11 Case top packing EDM EDML001 1 1 1 1 1 1 1 1 1 1 1 012 Exhaust connection packing DHN DHNL003 DEKA017 CRUK002 BUBK004 Terminal block mounting plate DHN 027 028 Conduit 92 120V EAU 029 Lamp seal pla...

Страница 16: ...EDME006 1 SAB1512 2 SAQ7708 1 8590109 1 EAUE001 1 DLTC001 1 CRPC052 1 CRUC045 1 CRUC046 1 EAUE005 1 Combustion tube SET DHN SET AS Plug packing Q CRU Burner sensor CRU A SET V Ignition plug CRU SET V...

Страница 17: ...ve heater 3 BGD O ring P22 O ring P22C Hot water outlet pipe DHN Bypass pipe DHN Hot water outlet thermostat 300 BWC SET V Water level sensor SET3 DHN SET V Water inlet thermostat 300 BWC SET V O ring...

Страница 18: ...Nylon clamp HP 4N NK 4N Nylon clamp HP 2N NK 2N Gas type change connector 1 CRU Gas type change connector 2 CRU Switch cover CYD 700 701 702 703 704 706 707 708 710 705 712 713 714 715 716 F point th...

Страница 19: ...llation Guide upon completion of the installation work Please put your information on the warranty card in the operation manual and give it to the customer when installation is completed Requests to i...

Страница 20: ...as those where gasoline benzene and adhesives are handled or places in which corrosive gases ammonia chlorine sulfur ethylene compounds acids are present Installation in an improper location may caus...

Страница 21: ...pace in front so as to facilitate inspection and repair of the equipment Leave sufficient distance when installing the water heater around permanent gas cooking equipment which can produce steam conta...

Страница 22: ...an be damaged and cause a danger of accident Be sure to mount the water heater on an upright wall Securing to the wall Mounting Water heater and building structure Mounting board upper Location of scr...

Страница 23: ...ystem by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa The appliance and its gas conn...

Страница 24: ...r a local plumbing inspector on how to control this situation A pressure relief valve must be installed near the hot water outlet that is rated in accordance with and complying with either The Standar...

Страница 25: ...eater in the water heater Tie the redundant cord outside the water heater Do not put the extra length inside the equipment Keep the remote controller cord length below 100 meters Use a Y type terminal...

Страница 26: ...valve Make sure to drain the water unless the unit will be used immediately This is to prevent the water from freezing and the water heater from being damaged Follow the instructions in the Owner s M...

Страница 27: ...Y PASS OPTIONAL RESISTOR GND Fully close SM LS Vcc V Vcc SM W W W W WW WW W W W W W W W W W O W W W W O O W W W W W W W W W O G V Y R R BK O G BK BR O G V BK BR BL Y BL O G V BK BK BR Y R BL Y R R BR...

Страница 28: ...entive packing Stay pipe Cap nut Connecting electric cord Wind the redundant cord here Connecting electric cord Outdoor cover Cap nut Take off the released paper For in wall wiring 1 Put the remote co...

Страница 29: ...n 0 98 Max 2 3 inches Inlet Gas Pressure Min 3 5 Max 10 5 inches Recovery Rate 313 Gallons Hour BTU Input Max 236 000 Min 21 000 Model N 084 Tel 949 420 0409 20492 Crescent Bay Dr Ste 104 Lake Forest...

Страница 30: ...58...

Отзывы: