background image

5

Important Safety Information

Do not drink water that has been inside the 

appliance for an extended period of time. Do 

not drink the first use of hot water from the 

appliance in the morning.
Clean the filter on the water inlet as 

frequently as required by the quality of  

your local water.
Keep the area around the appliance clean.

If boxes, weeds, cobwebs, cockroaches etc. are 

in the vicinity of the appliance, damage or fire 

can result.

Do not install the appliance where the 

exhaust will blow on walls or windows.
If the water supply is in excess of 12 gpg 

(200 mg/L) of hardness, acidic or otherwise 

impure, treat the water with approved 

methods in order to ensure full warranty 

coverage. (See page 17)
Problems resulting from scale formation are 

not covered by the warranty.
Check ignition during use and extinction after 

use.
Do not run water through the appliance when 

appliance is not on.

When discharging hot water, make sure the 

appliance is ON. If water is run through the 

appliance with the appliance OFF, water may 

condense inside the appliance and cause 

incomplete combustion or damage to the 

internal electrical components.

For single-handle fixtures, you’d turn the handle 

to the left.

This appliance is configured for installations 

up to 2,000 ft above sea level without 

changes.

For installations above 2,000 ft above sea levels, 

contact Noritz America for Instructions.

NOTICE

Do not disassemble the Remote Controller.
Do not use chlorine-based, acidic, alkaline 

detergents, organic solvents such as benzine 

and thinner, or Melamin Sponge to clean the 

Remote Controller.

This may cause discoloration, deformation, 

scratches or cracks.

Do not splash water on the Remote Controller. 

Do not expose the Remote Controller to 

steam.

Although it is water resistant, too much water 

can cause damage.

Do not locate the Remote Controller near 

stoves or ovens.

This may cause damage or failure.

Contact Noritz before using with a solar pre-

heater.
Preventing damage from freezing (See page 

13)

•  Damage can occur from frozen water within 

the appliance and pipes even in warm 

environments. Be sure to read below for 

appropriate measures.

•  Repairs for damage caused by freezing are 

not covered by the warranty.

Take necessary measures to prevent freezing 

of water and leakage of gas when leaving the 

appliance unused for long periods of time. 

(See page 13)
If it is snowing, check the exhaust vent 

terminal for blockage.

Содержание GQ-C2660WXQ-FF US

Страница 1: ...he Canadian Standard CAN CSA Z240 MH Mobile Homes Series M86 Noritz America reserves the right to discontinue or change at any time the designs and or specifications of its products without notice NOR...

Страница 2: ...dhesives in the same room or area near the Water Heater Keep flammable products 1 Far away from the Water Heater 2 In approved containers 3 Tightly closed 4 Out of children s reach Vapors 1 Cannot be...

Страница 3: ...ualified service technician replace it Do not plug or remove the valve Failure to follow these instructions can result in fire or explosion and personal injury or death Check the temperature of the ru...

Страница 4: ...y form inside the unit and or cause incomplete combustion damage to the electrical components or electric leakage Do not turn off the Water Heater while someone is bathing Do not cover the Water Heate...

Страница 5: ...internal electrical components For single handle fixtures you d turn the handle to the left This appliance is configured for installations up to 2 000 ft above sea level without changes For installati...

Страница 6: ...ial Operation 9 Using the Water Heater 10 Setting Hot Water Temperature 10 Customizable Settings 11 Limiting the Maximum Output Temperature 11 Muting the Remote Controller 12 Flow Meter Alarm 12 Stopp...

Страница 7: ...er is discharged from the condensate drain pipe approximately 2 gallons h 7 5 L h maximum It is not a water leak Do not plug or block the drain line as it must always be allowed to freely flow Note Th...

Страница 8: ...to the Installation Manual 1 POWER Button Indicator For turning the Water Heater ON OFF 2 SETTINGS Button For setting the flow meter alarm and other settings 3 Buttons For setting the hot water tempe...

Страница 9: ...you leave the button on and hot water is not used for more than 3 days the stored recirculation operation will be reset To avoid this turn the button off the Remote Controller when hot water will not...

Страница 10: ...g 105 F 2 Set the temperature using the buttons 1 The button is ON Operation The POWER indicator is displayed The previously set hot water supply temperature is shown Setting Hot Water Temperature NOT...

Страница 11: ...maximum output temperature can be set using the Remote Controller See Customizable Settings 60 C 140 F Display when high temperature is set e g 125 F NOTE Consult local codes for minimum operating te...

Страница 12: ...cannot be muted The high temperature warning tone when setting the unit to 125 F 55 C 131 F or higher will not emit a sound when muted 4 Turn on hot water 5 Turn off the hot water when the alarm sound...

Страница 13: ...ixtures to their original levels before using the Water Heater again to prevent scalding If there is still a risk that the Water Heater will freeze drain the Water Heater as shown on the next page 1 T...

Страница 14: ...D E F and wait until finish draining water b a Freeze damage due to not draining properly will not be covered under warranty Drain water into a bucket to prevent water damage 9 When the water is compl...

Страница 15: ...s been out of use for a long time make sure that you fill the condensate trap with water This is to prevent dangerous exhaust gases from entering the building Failure to fill the condensate trap could...

Страница 16: ...to clean the Remote Controller discoloration deformation scratches or cracks may occur The Remote Controller is water resistant but not water proof Keep it as dry as possible Water Drain Valve with W...

Страница 17: ...s 500 mg L or less Zinc 5 mg L or less Sulfate 250 mg L or less Residual chlorine 4 mg L or less Source EPA National Secondary Drinking Water Regulations 40 CFR Part 143 3 Maximum limit suggested by N...

Страница 18: ...ilable from NRCR111DV GQ C3260WXQ FF US is 8 7 GPM 33 L min at a 45 F 25 C temperature rise The maximum flow available from NRCR92DV GQ C2660WXQ FF US is 7 1 GPM 27 L min at a 45 F 25 C temperature ri...

Страница 19: ...ilure occurs information relating to the error blinks on the display If this occurs take appropriate measures as the following list The fan can be heard after operation is stopped A motor can be heard...

Страница 20: ...rranty period there will be a charge on any service and service will only be performed if the unit is deemed repairable Noritz will stock repair and maintenance parts for this unit for the time period...

Страница 21: ...mplete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit WARNING 1 Before the gas conversion is performed verify the prope...

Страница 22: ...on NG 218 W LP 202 W Freeze Prevention 114 W NG 185 W LP 175 W Freeze Prevention 114 W Maximum Current 4 Amps Materials Casing Front Cover Hot dipped zinc aluminum magnesium alloy coated steel w Polye...

Страница 23: ...y Period is the one used for a commercial capacity Condition C above 8 10 years or 12 500 operational burn hours whichever occurs first 9 5 years or 6 500 operational burn hours whichever occurs first...

Страница 24: ...RITZ AMERICA CORP 11160 Grace Avenue Fountain Valley CA 92708 Phone 714 433 2905 Fax 714 241 1514 4 What is Not Covered by this Warranty Please refer to the Installation Manual and Owner s Guide suppl...

Отзывы: