background image

21

Follow-up Service

*  A qualified service agency is any individual, firm, 

corporation, or company which either in person 

or through a representative is engaged in and is 

responsible for the connection, utilization, repair or 

servicing of gas utilization equipment or accessories; 

who is experienced in such work, familiar with all 

precautions required, and has compiled with all of the 

requirements of the authority having jurisdiction. 

•  If you move to a region that uses a different type 

of gas or if the local gas supply is converted, 

replacement of the gas manifold and adjustment 

of the appliance will be necessary.

•  This work must be performed by either Noritz or 

a qualified service agency and will be charged for 

even during the warranty period. The qualified 

installer will also be responsible for purchasing 

the gas conversion kit directly from the 

manufacturer.

•  For more information, contact Noritz America 

Technical Support at 1-866-766-7489.

Gas Conversion

•  The gas conversion kit shall be installed by 

a qualified service agency* in accordance 

with the manufacturer’s instructions and all 

applicable codes and requirements of the 

authority having jurisdiction.

•  The information in the instructions must 

be followed to minimize the risk of fire or 

explosion or to prevent property damage, 

personal injury, or death.

•  The qualified service agency is responsible for 

the proper installation of this kit.

•  The installation is not proper and complete 

until the operation of the converted appliance 

is checked as specified in the manufacturer’s 

instructions supplied with the kit.

WARNING

1.   Before the gas conversion is performed, verify 

the proper gas conversion kit with your Water 

Heater model on the table provided below.  

2.   The following parts are supplied in the 

conversion kit. These items will replace the 

existing parts that are currently installed in the 

Water Heater.

3.   After the necessary parts have been replaced on 

the Water Heater, the Remote Controller is then 

used to adjust the settings on the Water Heater 

for use with the proper gas type.

4.   The following pressure value are verified by the 

installer.

 

  -  The inlet gas pressure value at the gas supply 

inlet fitting

 

  - The offset pressure value at the gas valve

5.   Proper adjustments will be made to ensure safe 

and efficient operation.

6.   Once this is completed, a final gas leak check 

will be performed to confirm that all parts have 

been securely installed. 

NOTE

•  Make sure that all parts are 

replaced and properly installed by a 

qualified service agency.

•  A Noritz Remote Controller and a 

digital gas manometer are required 

to complete the installation. Do not 

proceed if this Water Heater is not 

immediately available.

NOTE

If you notice the smell of gas at any 

time after the installation has been 

completed, turn the Water Heater 

off and contact your gas supplier 

immediately.

Conversion Kit

Conversion Type

CK-82

Propane to Natural Gas

CK-83

Natural Gas to Propane

Venturi Mixer Set

O-Ring (× 2)

Conversion Kit Label

Gas Conversion 

Connector*

*  This connector is 

including in only CK-82 to 

convert from Propane to 

Natural Gas.

Содержание GQ-C2660WXQ-FF US

Страница 1: ...he Canadian Standard CAN CSA Z240 MH Mobile Homes Series M86 Noritz America reserves the right to discontinue or change at any time the designs and or specifications of its products without notice NOR...

Страница 2: ...dhesives in the same room or area near the Water Heater Keep flammable products 1 Far away from the Water Heater 2 In approved containers 3 Tightly closed 4 Out of children s reach Vapors 1 Cannot be...

Страница 3: ...ualified service technician replace it Do not plug or remove the valve Failure to follow these instructions can result in fire or explosion and personal injury or death Check the temperature of the ru...

Страница 4: ...y form inside the unit and or cause incomplete combustion damage to the electrical components or electric leakage Do not turn off the Water Heater while someone is bathing Do not cover the Water Heate...

Страница 5: ...internal electrical components For single handle fixtures you d turn the handle to the left This appliance is configured for installations up to 2 000 ft above sea level without changes For installati...

Страница 6: ...ial Operation 9 Using the Water Heater 10 Setting Hot Water Temperature 10 Customizable Settings 11 Limiting the Maximum Output Temperature 11 Muting the Remote Controller 12 Flow Meter Alarm 12 Stopp...

Страница 7: ...er is discharged from the condensate drain pipe approximately 2 gallons h 7 5 L h maximum It is not a water leak Do not plug or block the drain line as it must always be allowed to freely flow Note Th...

Страница 8: ...to the Installation Manual 1 POWER Button Indicator For turning the Water Heater ON OFF 2 SETTINGS Button For setting the flow meter alarm and other settings 3 Buttons For setting the hot water tempe...

Страница 9: ...you leave the button on and hot water is not used for more than 3 days the stored recirculation operation will be reset To avoid this turn the button off the Remote Controller when hot water will not...

Страница 10: ...g 105 F 2 Set the temperature using the buttons 1 The button is ON Operation The POWER indicator is displayed The previously set hot water supply temperature is shown Setting Hot Water Temperature NOT...

Страница 11: ...maximum output temperature can be set using the Remote Controller See Customizable Settings 60 C 140 F Display when high temperature is set e g 125 F NOTE Consult local codes for minimum operating te...

Страница 12: ...cannot be muted The high temperature warning tone when setting the unit to 125 F 55 C 131 F or higher will not emit a sound when muted 4 Turn on hot water 5 Turn off the hot water when the alarm sound...

Страница 13: ...ixtures to their original levels before using the Water Heater again to prevent scalding If there is still a risk that the Water Heater will freeze drain the Water Heater as shown on the next page 1 T...

Страница 14: ...D E F and wait until finish draining water b a Freeze damage due to not draining properly will not be covered under warranty Drain water into a bucket to prevent water damage 9 When the water is compl...

Страница 15: ...s been out of use for a long time make sure that you fill the condensate trap with water This is to prevent dangerous exhaust gases from entering the building Failure to fill the condensate trap could...

Страница 16: ...to clean the Remote Controller discoloration deformation scratches or cracks may occur The Remote Controller is water resistant but not water proof Keep it as dry as possible Water Drain Valve with W...

Страница 17: ...s 500 mg L or less Zinc 5 mg L or less Sulfate 250 mg L or less Residual chlorine 4 mg L or less Source EPA National Secondary Drinking Water Regulations 40 CFR Part 143 3 Maximum limit suggested by N...

Страница 18: ...ilable from NRCR111DV GQ C3260WXQ FF US is 8 7 GPM 33 L min at a 45 F 25 C temperature rise The maximum flow available from NRCR92DV GQ C2660WXQ FF US is 7 1 GPM 27 L min at a 45 F 25 C temperature ri...

Страница 19: ...ilure occurs information relating to the error blinks on the display If this occurs take appropriate measures as the following list The fan can be heard after operation is stopped A motor can be heard...

Страница 20: ...rranty period there will be a charge on any service and service will only be performed if the unit is deemed repairable Noritz will stock repair and maintenance parts for this unit for the time period...

Страница 21: ...mplete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit WARNING 1 Before the gas conversion is performed verify the prope...

Страница 22: ...on NG 218 W LP 202 W Freeze Prevention 114 W NG 185 W LP 175 W Freeze Prevention 114 W Maximum Current 4 Amps Materials Casing Front Cover Hot dipped zinc aluminum magnesium alloy coated steel w Polye...

Страница 23: ...y Period is the one used for a commercial capacity Condition C above 8 10 years or 12 500 operational burn hours whichever occurs first 9 5 years or 6 500 operational burn hours whichever occurs first...

Страница 24: ...RITZ AMERICA CORP 11160 Grace Avenue Fountain Valley CA 92708 Phone 714 433 2905 Fax 714 241 1514 4 What is Not Covered by this Warranty Please refer to the Installation Manual and Owner s Guide suppl...

Отзывы: