background image

29

(1)  Open a hot water fixture and confirm that the Burner On lamp comes on, and that hot water is 

being produced. (If necessary, repeat until the air in the gas piping is bled out).

*  White smoke may be noticed from the exhaust vent during cold weather. However, this is not a 

malfunction of the unit.

*  If an “11” error code appears on the remote controller, turn the unit off and then back on again, 

and then open a hot water fixture again.

(2)  Change the temperature setting on the remote controller and check that the water temperature changes.
•  If the water heater does not operate normally, refer to “Troubleshooting” in the Owner's Guide.

*  After the trial operation, clean the filter in the cold water inlet.

<If installed with a quick connect multi-system>

•  Turn the system power ON with the remote controller.

•  Slowly open a hot water fixture and check that the units ignite sequentially. Check to see that the 

hot water temperature is the same as the temperature displayed on the remote controller (*1)

* If both units do not ignite, switch which unit will ignite first by pressing the Max. or Min. Mani-fold

Pressure Set Button on the circuit board. (*2)

* If an 11 or F11 error code flashes on the remote controller, hit the Power Button on the remote  

controller off and on 2 -3 times.

* If (*1) and (*2) cannot be done, the Quick Connect Cord may not be properly connected.

  Check that the cord is properly connected.

13.

 

Maintenance

Periodically check the following to ensure proper

operation of the water heater.

•  The venting system must be examined periodically by a qualified service technician to check for 

any leaks or corrosion.

•  The burner flame must be checked periodically for a proper blue color and consistency. 

•  If the flame does not appear normal, the burner may need to be cleaned.

•  If the burner needs to be cleaned, it must be performed by a qualified service technician.

•  Do not obstruct the flow of combustion and ventilation air.

•  The pressure relief valve must be operated once a year to ensure that it is functioning properly and 

there is no obstruction. Turn the power off to the unit before opening the relief valve, and make sure 

that water draining out of the valve will not cause any damage.

•  If the relief valve discharges periodically, it may be due to thermal expansion in a closed water 

system. Contact the water supplier or a local plumbing inspector on how to correct this situation. 

  Do not plug the relief valve.

•  See the Owner's Guide for further maintenance.

Warning: 

There is a scald potential if the output temperature is set too high.

 

Should overheating occur, or the gas supply fail to shut off, turn off the manual gas control valve to the appliance.

 

Do not use this appliance if any part has been under water. Immediately call a qualified service  

technician to inspect the appliance and to replace any part of the control system and any gas control 

which has been under water.

 

Periodically check and clean the filter inside the cold water inlet of the unit.

14.

 

Trial Operation

The installer should test operate the unit, explain to

the customer how to use the unit, and give the owner

this manual before leaving the installation.

Unit A Ignites

Unit B Doesn't Ignite

Press Max. or Min. Manifold

Pressure Set Button on Unit B 

Unit A Doesn't Ignite

Unit B Ignites

•  Preparation ........... (1)  Open a hot water fixture to confirm that water is available, and then close 

the fixture.

   

(2)  Open the gas supply valve.

   

(3)  Turn on the power supply. Using the remote controller, turn on the Power 

On/Off button (the Operation lamp will turn on).

Содержание GQ-2857WX-F US

Страница 1: ...instructed in this manual are not covered by the warranty Check that the installation was done properly in accordance with this Installation Manual upon completion After completing installation please...

Страница 2: ...the units but may be necessary for installation Quick Connect Cord Q ty Shape Part Part Shape Q ty 1 1 Remote Controller Cord 26ft 8m 1 Isolation Valves includes pressure relief valve Pipe Cover PC 3S...

Страница 3: ...tor Cord Connector 3 Quick Connect Multi System Installation The Quick Connect Multi System allows the installation of two units together utilizing only the Quick Connect Cord Typical Plumbing The Qui...

Страница 4: ...line is sized for 199 900 Btuh for this unit Check the Power The power supply required is 120VAC at 60Hz May result in fire or electric shock Use Extreme Caution if Using With a Solar Pre Heater Usin...

Страница 5: ...which corrosive gases ammonia chlorine sulfur ethylene compounds acids are present Using the incorrect voltage may result in fire or cracking Avoid installation in places where dust or debris will acc...

Страница 6: ...r heater must be braced anchored or strapped to avoid moving during an earthquake Contact local utilities for code requirements in your area or call 1 866 766 7489 and request instructions Be sure to...

Страница 7: ...0mm or more on either side of the unit to facilitate inspection If possible leave 24 600mm or more in front of the unit to facilitate maintenance and service if necessary If possible leave 3 75mm or m...

Страница 8: ...opane Installation Code 2 In accordance with the current ANSI Z223 1 NFPA 54 National Fuel Gas Code A vent shall not terminate directly above a sidewalk or paved driveway that is located between two s...

Страница 9: ...ion Do not drop or apply unnecessary force to the device when installing Internal parts may be damaged and may become highly dangerous Install the unit on a vertical wall and ensure that it is level L...

Страница 10: ...instructions of the vent manufacturer Appliance Adapters When using a vent system other than N Vent an appliance adapter will be required to properly connect the vent to this appliance Consult the man...

Страница 11: ...on is recommended to prevent debris from falling into the water heater Install a condensation drain in the horizontal section of the venting For installations in tight spaces where there is not enough...

Страница 12: ...m clearance in front of the unit to the door If combustion air will be provided through a duct size the duct to provide 60 cubic feet of fresh air per minute Supply combustion air to the units as per...

Страница 13: ...he installer The installer must be professionally trained to do such work and must always follow all local and national codes and regulations Gas line sizing calculations must be performed for every i...

Страница 14: ...length from the meter or regulator so that the following supply pressures are available even at maximum demand WARNING Natural Gas Supply Pressure Min 4 WC Max 10 5 WC LP Gas Supply Pressure Min 8 WC...

Страница 15: ...45 13 5m Use 50 15m 175 000 Btuh requires 1 Outlet E 25 7 5m Use 30 9m 199 900 Btuh requires 3 4 Section 4 45 13 5m Use 50 15m 355 000 Btuh requires 1 1 4 Natural Gas Meter Noritz Tankless Gas Water...

Страница 16: ...ce to verify all appliances are receiving a minimum of 5 WC for NG or 8 WC for LP If all appliances are not receiving the minimum inlet pressure the gas piping system may need to be changed CAUTION Pi...

Страница 17: ...t be connected to any heating system or components previously used with a nonpotable water heating appliance When water is required in one part of the system at a higher temperature than in the rest o...

Страница 18: ...nd decreasing the durability of the heat exchanger Freeze Prevention Freezing is prevented within the device automatically unless the outside temperature without wind is below 30 F 35 C The room tempe...

Страница 19: ...ration is an example Please check with the actual water heater about the position of piping and form If this water heater will be installed in an application where the supply water is hard the water m...

Страница 20: ...n the other to the circulating pump 4 Connect the drain hose H2 to the circulating pump 5 Connect the drain hose H3 to the drain valve V4 6 Pour 1 gallon of and gallon water into the bucket Noritz rec...

Страница 21: ...the flushing solution through the water heater for 1 hour at a rate of 1 5 gallons per minute or more 5 The code C60 is displayed on the Remote Controller when the water heater detects the flow of th...

Страница 22: ...pply valves and water out let valves 9 Check for correct operation of the water heaters is displayed when the Main Water Heater s bule connector is connected is displayed when the Sub Water Heater s b...

Страница 23: ...ve with unions and a pressure relief valve Notes 1 Noritz recommends the use of an Isolation Kit with the installation These kits include an integrated shut off and service valve with unions and a pre...

Страница 24: ...icing Field wiring to be performed at time of appliance installation The electrical supply required by the water heater is 120VAC at 60 Hz The power consumption may be up to 262W or higher if using op...

Страница 25: ...On Off Button on the remote controller To keep the water heater off let the unit sit for 30 sec to return to the original display This unit can be programmed so that it will default to one of three te...

Страница 26: ...the end of the remote controller cord to the terminal block 5 Replace the terminal block cover and install the screw previously removed in step 3 6 Reconnect electrical power to the water heater Exte...

Страница 27: ...m a wall circuit to the pump 5 Replace the front cover Pump Wiring This feature is not available when using the Quick Connect Multi System feature Relay connection with larger pumps 85 W 1 Locate and...

Страница 28: ...mp Ground wire Connector Use one of the vacant holes Connector Connecting Quick Connect Cord 2 Caution For Quick Connect Multi System Installation use part QC 2 only sold separately Quick Connect Cord...

Страница 29: ...a proper blue color and consistency If the flame does not appear normal the burner may need to be cleaned If the burner needs to be cleaned it must be performed by a qualified service technician Do no...

Страница 30: ...ower to the unit 8 The unit will now operate whenever hot water is called for If the unit will not operate follow the shutdown instructions and call a service technician Shutdown Instructions 1 Stop a...

Страница 31: ...m 4 100mm 13 1 334mm 1 1 28mm 3 7 95mm 0 4 10mm 0 4 10mm 2 4 60mm 2 0 50mm 24 5 622mm 22 3 567mm 23 6 600mm 2 8 70mm 1 6 41mm 4 0 5 13mm FLUE COLLAR AIR INLET WIRING THROUGHWAY WATER DRAIN VALVE WATER...

Страница 32: ...s on the Installation Location The remote should be installed in an easily accessible location Avoid installing in a place where water or steam can come into contact with the controller Avoid location...

Страница 33: ...ord Phillips Roundhead Wood Screw Wall Anchor 3 Remove the cover of the remote control mark the location of the screw holes and drill holes for the wall anchors 4 Insert the wall anchors screw the rem...

Страница 34: ...r In order to use this product safely read this installation manual carefully and follow the installation instructions Potential dangers from accidents during installation and use are described below...

Страница 35: ...t The value in indicates the quantity Remote Controller Mounting bracket Raised countersunk head wood screw Wall anchor Raised countersunk head screw For junction box installation Machine screw When a...

Страница 36: ...f the remote controller and the frame pull the entire decorative frame forward while pressing the sections indicated where the fingers are in the figure below If it does not come off insert a flat hea...

Страница 37: ...higher temperature settings through the remote controller follow the below steps When setting the maximum temperature to 125 140 F 55 60 C 1 Turn the water heater off by pressing the Power On Off But...

Страница 38: ...e controller 2 Disconnect then reconnect electrical power to the water heater 3 Press the MENU Button inside the cover select Initial settings using the Buttons 4 Press the ENTER button the Initial se...

Отзывы: