background image

19

Combination Potable Water and Space Heating System

Isolation
Kit(*1)

Gas Supply

Backflow Preventer
(optional)

Check
Valve(*3)

Cold Water
Supply

Mixing Valve(*5)

Hot Water

Pump(*2)

Flow Switch(*4)

Fixtures

Air Handler

Optional
Expansion Tank(*6)

Recirculation System

Cold Water Supply

Isolation
Kit(*

)

Gas Supply

Aquastat(*2)

Hot Water

Optional 8-10 Gallon
Storage Tank
(To alleviate cold water sandwich)

Globe
Valve

Pump(*1)

Expansion Tank
(Install according
to local code)

Fixtures

Hot Water Return

R

B

W

Pump

120VAC

105

Neutral
Ground

Live

S

Use Honeywell Aquastat 

(Model L6006A or L6006C)

Aquastat Wiring

Notes:

1. Size the pump to provide a maximum of 1.5GPM 
    (5.7L/min.) through the system at 10ft (0.3m) of 
    head plus piping losses. 
    Adjust the flow using a globe valve and verify the 
    flow rate with the maintenance monitors.

2. Set the Aquastat to 10˚F below the set output temperature. 
    An aquastat is the minimum pump control requirement
    in order to maintain the full recirculation waranty.

3. Noritz recommends the use of an Isolation Kit
    with the installation.
    These kits include an integrated shut-off and service 
    valve with unions and a pressure relief valve. 

Notes:

1. Noritz recommends the use of an Isolation Kit with
    the installation.
    These kits include an integrated shut-off and service 
    valve with unions and a pressure relief valve.

2. Size the pump to provide a maximum of 2 GPM
    (7.5 L/min.) with a head pressure equal to the loss 
    through the water heater and Air Handler.

3. Check valve required if it is not included with the pump.

4. Set the flow switch to deactivate the Air Handler when
    the domestic hot water flow reaches 2 GPM (7.5 L/min.).
    Adjust as necessary to prevent cycling.  

5. If the system requires water for space heating at a higher 
    temperature than for other uses, means such as a
    mixing valve shall be provided to temper the water for
    the other uses to help prevent scalding.

7. The water heater cannot be used for space heating 
    applications only.
8. Only POTABLE water may be plumbed through
    the water heater.

6. Expansion tank required if a backflow preventer is installed.

NORITZ

Condensing
Tankless Gas

Water Heater

NORITZ

Condensing
Tankless Gas

Water Heater

If the Air Handler does not control the water flow automatically, the Scale detection feature will not work.

10.

 

Plumbing Applications

▲The illustration is an example. Please check with the actual water heater about the position of piping, and form.

Содержание ecoTOUGH NRC661A-OD

Страница 1: ...y and follow the in stallation instructions Failures and damage caused by erroneous work or work not as instructed in this manual are not covered by the warranty Check that the installation was done p...

Страница 2: ...d below are not included with the units but may be necessary for installation Cross Recessed Head Screw Q ty Shape Part Part Shape Q ty 1 Remote Controller Cord 26ft 8m 1 Isolation Valves includes pre...

Страница 3: ...re of the water supply as unexpected accidents may occur as a result Check Water Supply Quality If the water supply is in excess of 12 grains per gallon 200 mg L of hardness acidic or otherwise impure...

Страница 4: ...animals The heat and moisture from the water heater may cause discoloration of walls and resinous materials or corrosion of aluminum materials Do not locate the vent termination directed towards a win...

Страница 5: ...the unit in a location where the unit is out of reach such as the wall of the second floor When installing the unit in a common side corridor provide a clearance of 47 1 190mm or more in front of the...

Страница 6: ...tor assembly I Clearance to service regulator vent outlet J Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance K Clearance to a mechanical air s...

Страница 7: ...o not drop or apply unnecessary force to the device when installing Internal parts may be damaged and may become highly dangerous Install the unit on a vertical wall and ensure that it is level Locati...

Страница 8: ...ons or concerns CAUTION Regulators Ensure that all gas regulators used are operating properly and providing gas pressures within the specified range of the water heater being installed Excess gas inle...

Страница 9: ...length from the meter or regulator so that the following supply pressures are available even at maximum demand WARNING Natural Gas Supply Pressure Min 4 WC Max 10 5 WC LP Gas Supply Pressure Min 8 WC...

Страница 10: ...tuh NRC661A OD series 120 000 Btuh Table 2 For 8 WC 10 5 WC initial supply pressure Maximum Natural Gas Delivery Capacity 3 0 Pressure Drop Values in Table are in Cubic Feet of Gas per Hour 0 60 Speci...

Страница 11: ...nce to verify all appliances are receiving a minimum of 5 WC for NG or 8 WC for LP If all appliances are not receiving the minimum inlet pressure the gas piping system may need to be changed CAUTION P...

Страница 12: ...upply potable water may not be connected to any heating system or components previ ously used with a nonpotable water heating appliance When water is required in one part of the system at a higher tem...

Страница 13: ...r on the inlet If this is not done local boiling will occur inside the water heater causing abnormal sounds and decreasing the durability of the heat exchanger Freeze Prevention Freezing is prevented...

Страница 14: ...ng and form If this water heater will be installed in an application where the supply water is hard the water must be treated with either the Noritz H2Flow or ScaleShield or a water softener Refer to...

Страница 15: ...thorized Noritz Service Representative Any unauthorized use of this procedure may result in voiding the warranty Please contact Noritz America 866 766 7489 for additional support Procedure for Flushin...

Страница 16: ...ot disconnect the blue connector marked FLUSH for flushing on the Circuit Board 7 Turn off the circulating pump The flushing solution needs to be rinsed and cleaned out of the water heater Below is th...

Страница 17: ...nearest drain is above the water heater will require the use of a condensate pump Size the pump to allow for a maximum condensate discharge of 0 8 GPH from the water heater Horizontal runs must be slo...

Страница 18: ...n of piping and form Condensate piping to floor drain Condensate piping with pump Slope pipe downwards 1 4 per foot or more The end of the drain pipe must have an air gap 1 or more USE NON CORROSIVE M...

Страница 19: ...with unions and a pressure relief valve Notes 1 Noritz recommends the use of an Isolation Kit with the installation These kits include an integrated shut off and service valve with unions and a press...

Страница 20: ...The electrical supply required by the water heater is 120VAC at 60 Hz The power consumption may be up to 182W Use an appropriate circuit Do not disconnect the power supply when not in use When the po...

Страница 21: ...er heater back into operation press the Power On Off Button on the optional remote controller To keep the water heater off let the unit sit for 30 sec to return to the original display When changing t...

Страница 22: ...by pressing the Power On Off Button on the remote controller 2 Disconnect then reconnect electrical power to the water heater 3 Press the Flow Meter Alarm Set Button and hold it in for 2 seconds or mo...

Страница 23: ...efore opening the relief valve and make sure that water draining out of the valve will not cause any damage If the relief valve discharges periodically it may be due to thermal expansion in a closed w...

Страница 24: ...s stop and follow the instructions on page 3 of Owner s Guide 6 Turn the gas control manual valve counterclockwise to the on position 7 Turn on electric power to the unit 8 The unit will now operate w...

Страница 25: ...mm 3 5 90mm 3 0 3 0 6 6 5 16 5mm OBLONG HOLE 4 0 5 13mm WATER DRAIN VALVE HOT WATER OUTLET CONDENSATE DRAIN WATER DRAIN VALVE COLD WATER INLET WIRING THROUGHWAY GAS INLET AC120V WATER DRAIN VALVE WATE...

Страница 26: ...Location The remote should be installed in an easily accessible location Avoid installing in a place where water or steam can come into contact with the controller Avoid locations where special chemi...

Страница 27: ...ord Phillips Roundhead Wood Screw Wall Anchor 3 Remove the cover of the remote control mark the location of the screw holes and drill holes for the wall anchors 4 Insert the wall anchors screw the rem...

Страница 28: ...he wall pipe containing the remote controller wires through the hole 4 Slide the junction box packing and the junction box over the remote controller wires and wall pipe protruding from the outside wa...

Отзывы: