from an authorized Noritz wholesaler.

located

** Connect the blue connector marked "FLUSH" for flushing on the Circuit Board when flushing the Heat Exchanger.

7.  Place the both drain hoses (H2 and H3) into the bucket filled with the flushing solution.

1.  Close the gas supply valve.

2.  Close the water inlet valve (V1) and the water outlet valve (V2).

3.  Connect the one drain hose (H1) to the drain valve (V3), and then the other to the circulating 

   pump.

4.  Connect the drain hose (H2) to the circulating pump.
5.  Connect the drain hose (H3) to the drain valve (V4).

After connecting it, the water heater is set to “Flushing Mode”.

This procedure is only intended for use by a qualified service professional or authorized Noritz
Service Representative. Any unauthorized use of this procedure may result in voiding the
warranty.Please contact Noritz America (866-766-7489) for additional support.

Procedure for Flushing the Heat Exchanger

8.  Open the both drain valves (V3 and V4).

1.  Open the Front Cover.

2.  Connect the blue connector***** marked "FLUSH" for flushing on the Circuit Board.

3.  Then the code “CCC” is displayed on the 

㻰㼍㼠㼍㻌㻰㼕㼟㼜㼘㼍㼥

4.  Turn on the circulating pump to circulate the flushing solution through the water heater
    

 

for 1 hour at a rate of 1.5 gallons per minute or more.

5.  The code “C60” is displayed on the Data Display when the water heater detects the flow of the
     fflushing solution.
     When 1 minute passes, the code “C60” will change to “C59” on the Data Display.

Detects the flow

1 minute passes

Please check whether the reverse connection of the hose (H1) and (H3) if the display number will not change.

In that case, the flow rate of the flushing solution may be under 1.5 gallons per minute.

6.  When 1 hour passes, the code “C00” is flashing on the Data Display.
      Do not disconnect the blue connector marked "FLUSH" for flushing on the Circuit Board.

7.  Turn off the circulating pump.

The flushing solution needs to be rinsed and cleaned out of the water heater.

Below is the way to rinse and clean the flushing solution.

1.  Remove both drain hoses (H2 and H3) from the bucket. And then place the drain hose (H3)

     into the sink or outside to drain.

2.  Close the drain valve (V3) and then open the water inlet valve (V1).
     Do not open the fresh water outlet valve (V2).
3.  Clean the water heater with fresh water for 3 minutes or more.
     (Needs to have enough time to clean the water heater.)

4.  Close the drain valve (V4) and then remove the drain hose (H3)

     from the drain valve (V4).

5.  Remove the drain hose (H1) from the drain valve (V3).

8.  Open the gas supply valve and water outlet valve (V2).

9.  Check for correct operation of the water heater.

6.  Disconnect the blue connector marked "FLUSH" for flushing

 

on the Circuit Board.

     The code “C00” goes out on the Data Display.

7.  Close the  Front Cover.

If the error code “C #*~C #*” is flashing on the Display Window, it means there is Scale Build-up 

in the Heat Exchanger.The Heat Exchanger needs to be flushed** to remove the Scale Build-up.

Damage to the water heater due to Scale Build-up is not covered by the water heater's warranty.

To clear the error code “C #*~C #*”, the Heat Exchanger must be flushed.
If the error code “C #*” is displayed and flashing in the Display Window, please contact Noritz 

America (866-766-7489).

6.  Pour 1 gallon of "Calcium, Lime and Rest Removal Product"*** and 1 gallon water into the bucket.
     ***Notriz recommends "Calcium, Lime and Rest Removal Product" for flushing.

Содержание ecoTOUGH NRC661A-OD

Страница 1: ...y and follow the in stallation instructions Failures and damage caused by erroneous work or work not as instructed in this manual are not covered by the warranty Check that the installation was done p...

Страница 2: ...d below are not included with the units but may be necessary for installation Cross Recessed Head Screw Q ty Shape Part Part Shape Q ty 1 Remote Controller Cord 26ft 8m 1 Isolation Valves includes pre...

Страница 3: ...re of the water supply as unexpected accidents may occur as a result Check Water Supply Quality If the water supply is in excess of 12 grains per gallon 200 mg L of hardness acidic or otherwise impure...

Страница 4: ...animals The heat and moisture from the water heater may cause discoloration of walls and resinous materials or corrosion of aluminum materials Do not locate the vent termination directed towards a win...

Страница 5: ...the unit in a location where the unit is out of reach such as the wall of the second floor When installing the unit in a common side corridor provide a clearance of 47 1 190mm or more in front of the...

Страница 6: ...tor assembly I Clearance to service regulator vent outlet J Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance K Clearance to a mechanical air s...

Страница 7: ...o not drop or apply unnecessary force to the device when installing Internal parts may be damaged and may become highly dangerous Install the unit on a vertical wall and ensure that it is level Locati...

Страница 8: ...ons or concerns CAUTION Regulators Ensure that all gas regulators used are operating properly and providing gas pressures within the specified range of the water heater being installed Excess gas inle...

Страница 9: ...length from the meter or regulator so that the following supply pressures are available even at maximum demand WARNING Natural Gas Supply Pressure Min 4 WC Max 10 5 WC LP Gas Supply Pressure Min 8 WC...

Страница 10: ...tuh NRC661A OD series 120 000 Btuh Table 2 For 8 WC 10 5 WC initial supply pressure Maximum Natural Gas Delivery Capacity 3 0 Pressure Drop Values in Table are in Cubic Feet of Gas per Hour 0 60 Speci...

Страница 11: ...nce to verify all appliances are receiving a minimum of 5 WC for NG or 8 WC for LP If all appliances are not receiving the minimum inlet pressure the gas piping system may need to be changed CAUTION P...

Страница 12: ...upply potable water may not be connected to any heating system or components previ ously used with a nonpotable water heating appliance When water is required in one part of the system at a higher tem...

Страница 13: ...r on the inlet If this is not done local boiling will occur inside the water heater causing abnormal sounds and decreasing the durability of the heat exchanger Freeze Prevention Freezing is prevented...

Страница 14: ...ng and form If this water heater will be installed in an application where the supply water is hard the water must be treated with either the Noritz H2Flow or ScaleShield or a water softener Refer to...

Страница 15: ...thorized Noritz Service Representative Any unauthorized use of this procedure may result in voiding the warranty Please contact Noritz America 866 766 7489 for additional support Procedure for Flushin...

Страница 16: ...ot disconnect the blue connector marked FLUSH for flushing on the Circuit Board 7 Turn off the circulating pump The flushing solution needs to be rinsed and cleaned out of the water heater Below is th...

Страница 17: ...nearest drain is above the water heater will require the use of a condensate pump Size the pump to allow for a maximum condensate discharge of 0 8 GPH from the water heater Horizontal runs must be slo...

Страница 18: ...n of piping and form Condensate piping to floor drain Condensate piping with pump Slope pipe downwards 1 4 per foot or more The end of the drain pipe must have an air gap 1 or more USE NON CORROSIVE M...

Страница 19: ...with unions and a pressure relief valve Notes 1 Noritz recommends the use of an Isolation Kit with the installation These kits include an integrated shut off and service valve with unions and a press...

Страница 20: ...The electrical supply required by the water heater is 120VAC at 60 Hz The power consumption may be up to 182W Use an appropriate circuit Do not disconnect the power supply when not in use When the po...

Страница 21: ...er heater back into operation press the Power On Off Button on the optional remote controller To keep the water heater off let the unit sit for 30 sec to return to the original display When changing t...

Страница 22: ...by pressing the Power On Off Button on the remote controller 2 Disconnect then reconnect electrical power to the water heater 3 Press the Flow Meter Alarm Set Button and hold it in for 2 seconds or mo...

Страница 23: ...efore opening the relief valve and make sure that water draining out of the valve will not cause any damage If the relief valve discharges periodically it may be due to thermal expansion in a closed w...

Страница 24: ...s stop and follow the instructions on page 3 of Owner s Guide 6 Turn the gas control manual valve counterclockwise to the on position 7 Turn on electric power to the unit 8 The unit will now operate w...

Страница 25: ...mm 3 5 90mm 3 0 3 0 6 6 5 16 5mm OBLONG HOLE 4 0 5 13mm WATER DRAIN VALVE HOT WATER OUTLET CONDENSATE DRAIN WATER DRAIN VALVE COLD WATER INLET WIRING THROUGHWAY GAS INLET AC120V WATER DRAIN VALVE WATE...

Страница 26: ...Location The remote should be installed in an easily accessible location Avoid installing in a place where water or steam can come into contact with the controller Avoid locations where special chemi...

Страница 27: ...ord Phillips Roundhead Wood Screw Wall Anchor 3 Remove the cover of the remote control mark the location of the screw holes and drill holes for the wall anchors 4 Insert the wall anchors screw the rem...

Страница 28: ...he wall pipe containing the remote controller wires through the hole 4 Slide the junction box packing and the junction box over the remote controller wires and wall pipe protruding from the outside wa...

Отзывы: