Norgren HERION 1-NPT Скачать руководство пользователя страница 2

Content

 1  Information about these instructions 

03

 1.1 Validity of documentation 

03

 1.2 Explanation of symbols 

03

 1.3 Risk categories (ANSI Z535.6) 

03

 1.4 Used symbols and signal words 

03

 1.5 Liability and warranty 

04

 1.6 Manufacturer‘s address 

04

 

2

 

 General safety instructions 

05

 2.1 Intended use 

05

 2.2 Not intended use 

05

 2.3 General risks 

05

 2.5 Personal protective equipment 

06

 2.6 Log book 

06

 3  Technical specifications, design and function 

07

 3.1 SCVA08/SCVA10/SCVA20/SCVA32 

07

 3.2 Materials 

12

 3.3 Requirements for operating media 

12

 3.4 Noise emissions 

12

 3.5 Design and function 

13

 4  Labelling 

14

 5  Transport and storage 

14

 5.1 Transport 

14

 5.2 Storage 

14

 6  Installation 

15

 6.1 Pneumatic connection 

15

 6.1 Electrical connection 

16

 7  Test 

17

 8  Servicing 

17

 9  Disposal 

18

10  Declaration of conformity 

19

7503618000000006 

002

Incorporating

SCVA

02/22

Our policy is one of continued research and development. We therefore reserve the right to amend,

without notice, the specifi cations given in this document. © 2014 Norgren Ltd

Содержание HERION 1-NPT

Страница 1: ...reproduced transcribed or transmitted in any form without the written consent of the publisher Every effort has been made to ensure that the information contained in this manual is accurate All rights...

Страница 2: ...ifications design and function 07 3 1 SCVA08 SCVA10 SCVA20 SCVA32 07 3 2 Materials 12 3 3 Requirements for operating media 12 3 4 Noise emissions 12 3 5 Design and function 13 4 Labelling 14 5 Transpo...

Страница 3: ...n DANGER warning integrated in text WARNING CAUTION ADVICE specific values respectively fixed attributes Example info A tight pressure system contributes energy savings thus ressources and the environ...

Страница 4: ...uthorised and trained by the manufacturer Failure to observe the above will void the warranty The manufacturer accepts no liability for damages incurred 1 6 Manufacturer s address Norgren GmbH Stuttga...

Страница 5: ...quality 2 3 General risks The following section lists residual risks which may be present even if the safety valves are used correctly DANGER Danger caused by hazardous movements When the power is sw...

Страница 6: ...ts a log book must be kept of all activities invol ving the safety valves WARNING Danger of injury caused by noise The noise level that occurs can seriously damage your hearing Always wear ear protect...

Страница 7: ...3 kg SCVA32 Voltage solenoid type 3052 0200 0800 DC or AC voltage Power consumption with 24 V DC 230 V AC 4 8 W Solenoid 3052 11 W Solenoid 0200 16 W Solenoid 0800 Solenoid protection class IP 65 Elec...

Страница 8: ...ction 1 G1 4 or 1 4 NPT 2 Line connection 2 G1 4 or 1 4 NPT 3 Flange surface for pressure switch 7503618000000006 008 Incorporating SCVA 02 22 Our policy is one of continued research and development W...

Страница 9: ...2 Line connection 2 G1 2 or 1 2 NPT 3 Flange surface for pressure switch 7503618000000006 009 Incorporating SCVA 02 22 Our policy is one of continued research and development We therefore reserve the...

Страница 10: ...connection 1 G1 2 or 1 2 NPT 2 Line connection 2 G1 2 or 1 2 NPT 3 Flange surface for pressure switch 7503618000000006 010 Incorporating SCVA 02 22 Our policy is one of continued research and developm...

Страница 11: ...e connection 1 G1 2 or 1 2 NPT 2 Line connection 2 G1 2 or 1 2 NPT 3 Flange surface for pressure switch 7503618000000006 011 Incorporating SCVA 02 22 Our policy is one of continued research and develo...

Страница 12: ...rding to ISO 85731 1 2010 7 3 4 7 Particle size 40 m Particle concentration 10 mg m 3 Dew point under pressure 20 C 4 Oil concentration 5 mg m 1 Gauge 2 Volume 3 Valve 4 Silencer 5 Noise level at meas...

Страница 13: ...actuated with a time difference 0 5 s The dynamic monitoring system detects the delay ed actuation and prevents pressure build up at working connection 2 A Y1 Y1 Y1 Y2 Y2 Y2 3 5 Design and function T...

Страница 14: ...its in the box they were shipped in Do not store them outdoors Store them in a dry dust free place Don t expose them to aggressive media such as salty air Protect them from direct sunlight Storage tem...

Страница 15: ...6 Installation Before installation of the valve please note Create a safety zone around the hazardous area in accordance with the risk assess ment for the machine or equipment For new systems ensure t...

Страница 16: ...manu facturer see section 1 6 Manufacturer s address 2 Connect the safety valves in accordance with the specifications on the type plate ADVICE If using a two hand control ensure that the actuating s...

Страница 17: ...s actuate it again Piston moves at first After deactuation of solenoid Y2 piston returns to initial position and remains there 8 Servicing WARNING Danger of injury caused by improper maintenance Impro...

Страница 18: ...e parts after shut ting down of the valve Apply reusable materials to recycling ADVICE Improper disposal may cause an environmental hazard Improper disposal may result in risks to the environment At t...

Страница 19: ...ts of control system Part 1 General principles for design EN ISO 4414 2010 Pneumatic fluid power General rules and safety requirements for systems and their components Notified body Deutsche Gesetzlic...

Страница 20: ...presen ted in it are the sole property of Norgren GmbH It may not be reproduced or given to third parties without their consent Subject to change without notice Printed in Germany These instructions w...

Отзывы: