background image

Drs. 

Nicholas 

and 

Dorothy 

Cummings 

Center 

for 

the 

History 

of 

Psychology 

Special 

Interest 

Collection, 

The 

University 

of 

Akron 

Содержание carry-corder 150 EL3302

Страница 1: ... S 7 Operating Instruction Manual 1 orelco Tape Cassette CARRY CORDER 150 MODEL EL3302 Drs Nicholas and Dorothy Cummings Center for the History of Psychology Special Interest Collection The University of Akron ...

Страница 2: ... and electronic standards Understanclnhl you He nnxious to begin using your nr1v tape rer order howt rr r urge you to takP the lime lo n ad llwse simp inslrur l ions Thry arr dPsigned lo lwlp Oll Qain the utmost in Pnj o menl and pprform anr t from your lorelco lnpr n cordPr In this hookiPI Ou ill find the basic opt rdtJn and mainlr nanc e pro c Prl ures pi us nddil ionnl in forma Iion you should ...

Страница 3: ... nnd conncclions ore inciJccJied in lhc text wh ere ncces tory B PLAY RECORD C D REWIND FORWARD A STOP Drs Nicholas and Dorothy Cummings Center for the History of Psychology Special Interest Collection The University of Akron ...

Страница 4: ...nc tions of the Carry Corder are acti vated by the movement of the Function Control Knob 9 from this position starting point neutral Always make sure the Carry Corder is in this mode after use storage B PLAY RECORD Push control knob fo rward A in direction of B to s ta rt tape movement for playback or recording Pull control back to Stop A to stop tape m ovement C REWIND Push and hold control knob ...

Страница 5: ...eo cassette is played on a monaural recorder the playback head w ill scan both the left and right channels together This re sults in automatic mixing of the left and right channels from the stereo tape giving you true monaural reproduc tion without any loss in the quality of the playback Be cause of the compatibility most prerecorded Musicas settes are compact tape cassette stereo recordings and c...

Страница 6: ...ion The drive mechanism continues to operate therefore return the Function Knob 9 to the Stop position when the end of the tape is reached There is a viewing window on each side of a cassette The tape can be seen through this window and a rough estimate can be made of the amount of tape still avail able for recording or playback INSERTING THE CASSETTE Make sure Function Knob 9 is in the Stop posit...

Страница 7: ...he cassette safely stored for long periods of time The cas sette will fit only into the storage box in one way The open end of the cassette should be fitted into the box The box is designed to lock the hubs of the cassette to keep them from moving the tape remains in the same position as when it was stored ready for instant use Store the cassette at room temperature not near any source of heat and...

Страница 8: ...e Carry Corder Serial Number The serial number of the Carry Corder is directly under the battery flap diagram REPLACING BATTERY COMPARTMENT COVER Slide the cover in place until the lip of the cover is under the case push down back of cover to snap it in place Checking the Batteries Check the condition of the batteries after they have been installed and again each time the recorder is used The VU M...

Страница 9: ...re connected as follows Playback Grey phono plug to external amplifier high level input i e radio TV auxiliary etc Record Red phona plug to external signal source i e radio tuner phono second recorder etc FORWARD AND REWIND The Forward and Rewind functions are used in conjunction with the cassette index to locate particular selections on a tape or to forward or rewind the tape at high speed REWIND...

Страница 10: ...because increasing the volume of the loudspeaker places a greater drain on the batteries and therefore shortens the battery life 3 The Remote Control microphone switch can be used to stop start playback 4 When in the Play Record position the t pe in the cassette will stop automatically when it reaches the end However the drive mechanism and transistors continue to draw power from the batteries the...

Страница 11: ...rmly in place Connect the three pin Microphone Plug 5 lo Socket 1 Use of the stop start switch is optional Remote Control connect to Socket 2 Watch the VU Meter 10 while recording The needle should just enter the red area of the scale only on oc casional loud passages Very soft passages may be given a higher recording level setting REMOTE CONTROL REMOTE CONTROL MICROPHONE SWITCH Both the record an...

Страница 12: ...onged periods of time ACCIDENTAL ERASURE SAFETY FEATURE The compact cassette is provided with a recording in terlock safety feature to prevent accidental erasures of prerecorded tapes it prevents the Record Lock pushbut ton 8 from functioning The cassette has two sides labeled A and B To prevent accidental erasures in the rear of the cassette two knockout tabs 1 for each side are provided and they...

Страница 13: ...ape is fully wound on the left side of the cassette Use the Rewind function if necessary Connect the program source microphone radio tuner phono etc to the appropriate inpu socket on the Carry Corder Turn the Record Level Control 4 to 0 To start tape movement and recording hold down the red Record Lock safety pushbutton B and move the Function Knob 9 to the Play Record A position The Record Lock p...

Страница 14: ...all stick moistened with a little alcohol common household rubbing alcohol and clean the heads a and b the rubber pressure roller c and the capstan d Clean after approximately 20 hours of use CAUTION Use alcohol only Commercial tape head cleaners may react unfavorably with the encapsulating compounds used in the record playback and erase heads Never clean the heads with a sharp or metal object Do ...

Страница 15: ...in each side C90 60 min each side C120 Less than 70 seconds C60 cassette Admissible Ambient Temperature Combined input output jack 1 for microphone radio amplifier record player second recorder Accessory jack 2 5 pole 240 DIN for Jack for External Loudspeaker Headphone Housing Weight with Batteries Dimensions input pins 1 and 4 parallel 0 2 mV 2 k ohms output pins 3 and 5 parallel 0 5 V 20 k ohms ...

Страница 16: ... 9 1 0 II AOJUSTWENT gA9 c o I L 4 PATCH CORD IOOOpF 39000pF 18 Al9 P IIAT NO H68t0 t TO EICTEANAL AWP 1 ooo a ZK T I V GREY f 3 05 I 1 t Gc c 6 NPUT ERASEn H2 1 22o 6 F 33v 4146 AEO HEAD O Y J 7 4v J2 fo w o lu f t W 1 _LPIN UP T 500V l0 M l_ POLYESTER I T F LATFOILJ z50V IO L_ _____ _ _ ___j NORELCO CARRY CORDER ISO MODEL NO El 3302 94G JJH 611 16 Drs Nicholas and Dorothy Cummings Center for the...

Страница 17: ...nswer to the following please check Did you purchase this recorder for Entertainment Educational purposes D P rofessional or business use Did you purchase the recorder from D Radio music store D Appliance shop D Record shop D Department store D Camera shop D Other D Drs Nicholas and Dorothy Cummings Center for the History of Psychology Special Interest Collection The University of Akron ...

Страница 18: ...t T North American Philips Corporation 30 30 Review Avenue Long Island City New York 11101 PLACE STAMP HERE Drs Nicholas and Dorothy Cummings Center for the History of Psychology Special Interest Collection The University of Akron ...

Страница 19: ...th the AC Adopter use leakproof batteries To use the AC Adapter to revitalize the batteries leave the AC Adapter connected as above but make sure that th e machine is off Observe the follow ing I Do not attempt to revitalize fresh batteries before the batteries hove been used otherwise the batteries may be spoiled 2 To freshen up the batteries charge for approximate ly 2 hours To fully revitalize ...

Страница 20: ...e NORELCO tape re corder which have been c lged by battery lea kage subjected to m is ues neglect accident co Ct wiring not our own improper installa tion or to use in vjr I Hion of instructions furnished by us nor to any NORELCO tape order which may have been tampered with altered or repaired outside of our factory or authorized service st ations This warranty is in lieu of all other warranties e...

Страница 21: ... CORPORATION HIGH FIDELITY PRODUCTS DIVISION 100 East 42nd Street New York New York 10017 Printed in Holland 969 1 23613 H H Drs Nicholas and Dorothy Cummings Center for the History of Psychology Special Interest Collection The University of Akron ...

Отзывы: