background image

21

Figure 11. Q5RD / PPH2RD Series Wiring Diagram - 3, 4 & 5 Ton Units

OUTDOOR F

A

N

M

OTO

R

T1

T4

T3

T2

T5

G

N

L

C

L1

T1

L2

T2

4

3

2

1

8

7

6

5

9

TO

 “

G

” 

O

N

T-

S

TAT

3 AMP

FUSE

BLO

WER

RELA

Y

BLO

WER

MO

T

O

R

REVERSING

VA

LV

E

COIL

DEFR

OST

SENSOR

DU

AL

CAP

A

C

IT

OR

COMPRESSOR

TRANSFORMER

240V

24V

COM

OUTDOOR THERMOST

A

T

 (24)

(ON SELECT MODELS

BR

O

W

N JUMPER

IS INST

ALLED)

COMPRESSOR

CONT

A

C

T

O

R

Y

C

O

W2
R

E

DEFR

OST

CONTR

O

L

BO

ARD

DFT
E

R

W2

O

Y

C

T2

T1

DF1

DF2

Y

C

O

W2
R

E

DEFR

OST

CONTR

O

L

BO

ARD

DFT
E

R

W2

O

Y

C

T2

T1

DF1

DF2

Y

C

O

W2
R

E

DEFR

OST

CONTR

O

L

BO

ARD

DFT
E

R

W2

O

Y

C

T2

T1

DF1

DF2

BLUE

ORANGE

RED

YELLO

W

BLA

C

K

H

C

F

C

R

S

S

C

R

T1

T2

L2

L1

BLA

C

K

BLA

C

K

HIGH

PRESSURE

SWITCH (28)

LO

W

PRESSURE

SWITCH (25)

(SELECT MODELS ONL

Y

)

1

3

BLA

C

K

RED

RED

RED

WHITE

BLA

C

K

GREEN

RED

BLA

C

K

BLUE

BLA

C

K

GREY

BLA

C

K

ORANGE

WHITE

RED

GREEN/YELLO

W

RED

BLUE

ORANGE

YELLO

W

GREY

BR

O

W

N

RED

BR

O

W

N

Z

H

0

6

T

L

O

0

3

2/

8

0

2

4.

 For replacement wires use conductor

s suitab

le f

o

r 105° C.

5.

 On models w/no pressure s

witc

h,

 Y

ello

w J

umper connects 

    

“Y”

 & 

“T1”

 on Defr

ost Boar

d.

7.

 Couper le courant a

v

ant de faire letretien.

 

8.

 Emplo

y

ez uniquement des conducteur

s

    en cuivre

.

9.

 Ne con

v

ient pas aux installations de plus

    de 150V a la terre

.

FIELD WIRING

LEGEND:

LO

W V

O

LT

A

G

E

HIGH V

O

LT

A

G

E

WIRING DIA

GRAM

SMALL P

A

CKA

GED HEA

T PUMP- SINGLE PHASE

NO

TES:

1.

 Disconnect all po

wer bef

ore ser

vicing.

2.

 For suppl

y connections use copper conductor

s onl

y

.

3.

 Not suitab

le on systems that e

xceed 150V to gr

ound.

¢711094&¤

MO

D

E

L

OR

A

N

G

E

WI

R

E

RE

D

WI

R

E

036

TT

04

2

TT

048

TT

2

3

2

2

3

3

FACTORY SET

INDOOR MOTOR WIRING

ORANGE WIRE IS HEATING/COOLING 

SPEED

RED WIRE IS AUX. HEATING SPEED

(ELECTRIC HEAT)

REFER TO INSTALLATION INSTRUCTIONS 

FOR CFM DATA.

060

TT 43

7110940

(Replaces 7108370)

0310

Содержание Q5RD Series

Страница 1: ...check the instructions and follow recommendations given If these suggestions don t eliminate your problem call your servicing contractor These instructions are primarily intended to assist qualified i...

Страница 2: ...Low Pressure Switch 13 High Pressure Switch 13 Unit Maintenance 13 Figures Tables 13 Figure 9 Unit Dimensions 13 Table 4 Q5RD Physical Data 13 Charging Tables Cooling Mode 14 Table 5 Q5RD X24K 2 Ton U...

Страница 3: ...f the heat pump will result in an increase in electric utility costs Defrost During cold weather heating operation the outdoor unit will develop a coating of snow and ice on the heat transfer coil Thi...

Страница 4: ...tdoor coil must be maintained in order to achieve rated performance See Figure 2 page 5 for minimum clearances to obstructions Consideration should also be given to availability of electric power serv...

Страница 5: ...ngto NationalFireProtectionAssociation Batterymarch Park Quincy ME 02269 or visit www NFPA org on the web Design the duct work according to methods described by the Air Conditioning Contractors of Ame...

Страница 6: ...tion from under the home by cuttingasmallholeinthesub floor Determine how the floor joist location will affect cutting the opening needed for the return air box NOTE Floor joists are generally located...

Страница 7: ...t a hole approximately 3 4 larger than the damper opening in the fiberboard 3 Cut a 9 1 8 x 13 1 8 hole in the duct and bend over all tabs flat on the inside of the heat duct 4 Insert the damper into...

Страница 8: ...e energizing the outdoor unit See unit data label for proper incoming field wiring Any other wiring methods must be acceptable to authority having jurisdiction Providepowersupplyfortheunitinaccordance...

Страница 9: ...1650 T5 High 1950 Denotes Factory Set Low Speed Cooling Heating Denotes Factory Set High Speed Cooling Heating Denotes Factory Set Electric Heating Speed Overcurrent Protection Overcurrent protection...

Страница 10: ...a proper location Start Up Procedure The control circuit consists of an anti short cycle timer that will not let the compressor re start before 5 minutes have elapsed 1 Set the system mode to OFF and...

Страница 11: ...above the Terminate Temperature setting Short the TEST pins for 1 second or more to force the control out of defrost and back to heating mode reversing valve de energized Compressor will start immedia...

Страница 12: ...s necessary using a mild detergent and water Rinse thoroughly with water Inspecttheelectricalconnectionsfortightness at the beginning of each heating and cooling season Service as necessary CAUTION Th...

Страница 13: ...Control Access Panel Blower Access Panel H 17 86 15 36 10 10 3 4 NPT Drain Connection 1 12 13 1 38 3 2 3 2 5 29 FIGURES TABLES Q5RD Length L Width W Height H A B 024K 49 35 22 2 40 15 7 61 030K 49 35...

Страница 14: ...mp Liq Press Dis Temp Liq Press Dis Temp Liq Press Dis Temp Liq Press Dis Temp Liq Press Dis Temp Liq Press Dis Temp 139 258 115 141 260 121 281 121 143 262 126 283 126 304 126 145 266 129 285 131 306...

Страница 15: ...mp Liq Press Dis Temp Liq Press Dis Temp Liq Press Dis Temp Liq Press Dis Temp Liq Press Dis Temp Liq Press Dis Temp 134 269 129 136 271 135 293 134 138 274 140 295 139 316 138 140 279 139 297 144 318...

Страница 16: ...s Temp Liq Press Dis Temp Liq Press Dis Temp Liq Press Dis Temp Liq Press Dis Temp Liq Press Dis Temp Liq Press Dis Temp 124 126 274 101 128 276 112 295 111 130 277 124 298 121 318 119 132 279 129 300...

Страница 17: ...ated design values The suction pressure will vary from design value if outdoor air fl ow entering dry bulb or entering wet bulb temperatures vary 1 All pressures are listed psig and all temperatures i...

Страница 18: ...ated design values The suction pressure will vary from design value if outdoor air fl ow entering dry bulb or entering wet bulb temperatures vary 1 All pressures are listed psig and all temperatures i...

Страница 19: ...137 73 305 142 87 334 154 103 365 173 119 396 192 35 231 126 48 257 131 61 283 135 74 309 140 88 341 151 104 372 168 120 403 186 36 238 124 49 263 129 62 288 133 75 313 138 89 348 148 105 379 164 121...

Страница 20: ...D HIGH PRESSURE SWITCH LOW PRESSURE SWITCH SELECT MODELS ONLY BLUE BLUE RED RED RED RED RED ORANGE YELLOW WHITE WHITE WHITE WHITE GREY BROWN BLACK BLACK GREEN BROWN ORANGE BLUE BLACK BROWN BROWN RED R...

Страница 21: ...CK BLUE BLACK GREY BLACK ORANGE WHITE RED GREEN YELLOW RED BLUE ORANGE YELLOW GREY BROWN RED BROWN Z H 0 6 T L O V 0 3 2 8 0 2 4 For replacement wires use conductors suitable for 105 C 5 On models w n...

Страница 22: ...Accessory Heat Plug Outdoor Thermostat Factory Option Typical Wiring Field Supplied for 1 Stage Cool 1 Stage Electric Heat INDOOR T STAT SUB BASE Green DEFROST BOARD 1 2 3 4 5 6 7 8 9 Brown Orange Ac...

Страница 23: ...23...

Страница 24: ...ndusingcommonsenseplays an important role as well Pay attention to all safety warnings and any other special notes highlighted in the manual Improper installation of the furnace or failuretofollowsafe...

Отзывы: