Table A-5 Direct Drive Blower Set-Up
Blower Set-Up
Cooling Capacity
0.20 in. w.c.
0.50 in. w.c.
Furnace Model
Blower
Speed Motor Speed Motor Tons Power
CFM
Range
O5LD-070A-12-R
10-10T
DD
Low
1/2 HP
Med-Low
1/2 HP
3
1/2 HP
700 – 1600
O5LD-091A-12-R
10-10T
DD
Med-Low
1/2 HP
Med-Low
1/2 HP
3
1/2 HP
700 – 1600
O5LD-105A-12-R
10-10T
DD Med-Low
1/2
HP
Med-
High
1/2 HP
3
1/2 HP
700 – 1600
Table A-6 Direct Drive Blower Characteristics
CFM
External Static Pressure – Inches w.c.
Furnace Model
Blower
Motor
HP
Motor
FLA
T
Speed
0.2 0.3 0.4 0.5 0.6
High
1722 1645 1516 1462 1375
O5LD-A-12-R
Med-
High
1604 1545 1473 1383 1302
Med-
Low
1147 1133 1106 1063 1013
070 - 105
10-10T
DD
1/2 HP
7.1
70°F
Low
747 738 720 702 669
12