2.6.3.14 Alarm Status Read Command
This command returns the status of each of the dispenser alarms.
Client command and data:
(STX) + 04 + EL-- + CB + (ETX)
The above text packet in hexadecimal format:
STX
0
4
E
L
space space
C
B
ETX
0x02
0x30
0x34
0x45
0x4C
0x20
0x20
0x43
0x42
0x03
NOTE:
“D0” is the letter “D” followed by the digit “0.”
Return Format:
D0INiPApAIa
i:
input Alarm Status: 1= Alarm is set, 2= No alarm
p:
Pressure Alarm Status
a:
Auto Increment Alarm Status
EXAMPLE:
If the Pressure Alarm Status is “Alarm is set,” the text packet received from the dispenser is:
(STX) + 0B + D0IN2 D3 + (ETX)
Length of the response text packet:
Decimal 11 or hexadecimal 0B
The above text packet in hexadecimal format:
STX
0
B
D
0
I
N
2
P
A
1
A
I
2
0x02
0x30
0x42
0x44
0x30
0x49
0x4E
0x32
0x50
0x41
0x31
0x41
0x49
0x32
D
3
ETX
0x44
0x33
0x03
Appendix B — RS‑232 Protocol (continued)
Ultimus V High Precision Fluid Dispenser
74
www.nordsonefd.com [email protected]