Sample Memory Cell Settings
NOTES:
• When dispensing fluids that change viscosity, it is generally better to set Auto Increment to Time instead of Count.
• Within the individual memory cells, it is preferable to leave the dispense time the same, and only change the
pressure from cell to cell in order to maintain the same cycle rate.
• It is recommended to use small pressure adjustments or allow some settling time to ensure consistent deposit
amounts.
Cell 0 — Set initial parameters to produce the desired dot size. For example: 20 psi pressure, 0.150 seconds
dispense time, 0 vacuum. Set the trigger value to 900 (15 minutes).
Cell 1 — Increase pressure to 23 psi, keep 0.150 seconds dispense time, 0 vacuum. Set the trigger value to 900 (15
minutes).
Cell 2 — Increase pressure to 27 psi, keep 0.150 seconds dispense time, 0 vacuum. Set the trigger value to 900 (15
minutes).
Cell 3 — Increase pressure to 32 psi, keep 0.150 seconds dispense time, 0 vacuum. Decrease the trigger value to
540 (9 minutes).
Cell 4 — Increase pressure to 37 psi, keep 0.150 seconds dispense time, 0 vacuum. Set the trigger value to 540 (9
minutes).
Cell 5 — Increase pressure to 45 psi, keep 0.150 seconds dispense time, 0 vacuum. Set the trigger value to 540 (9
minutes).
Cell 6 — Increase pressure to 55 psi, keep 0.150 seconds dispense time, 0 vacuum. Decrease the trigger value to
360 (6 minutes).
Cell 7 — Increase pressure to 65 psi, keep 0.150 seconds dispense time, 0 vacuum. Decrease the trigger value to
180 (3 minutes).
Cell 8 — (last cell) — Increase pressure to 80 psi, keep 0.150 dispense time, 0 vacuum. Decrease the trigger value
to 120 (2 minutes).
If the Auto Increment Alarm is enabled in the Alarm Options screen, the Auto Increment alarm will engage and
further dispensing cycles will be stopped. If the Auto Increment Alarm is disabled, the timer will continue to
increment and dispense cycles will still be allowed — however, the memory cell address will no longer advance, and
will remain at the End Address settings.
NOTES:
• Setting the parameters in the cells needs to be done only one time. When the material reaches the end of its
working life, simply replace it with a full syringe and use the same preset parameters.
• To start over, highlight AI, then press F2 (Reset). If the AI Alarm is used, resetting the alarm will also reset the AI
mode.
Using Auto Increment Mode (continued)
Ultimus V High Precision Fluid Dispenser
31
www.nordsonefd.com [email protected]