1601056-05
Atomizing Air Adjustment
See Figure 1 and Figure 2
. Use the atomizing air regulator (3) to adjust atomizing air flow.
• Rotate the regulator to the right (clockwise) to decrease atomizing air.
• Rotate the regulator to the left (counterclockwise) to increase atomizing air.
Material Flow Adjustment
See Figure 1
. The material flow regulator (2) adjusts the material flow rate.
Loosen the lock nut (2a) before adjusting the flow.
•
Rotate the regulator to the right (clockwise) to decrease material flow.
•
Rotate the regulator to the left (counter-clockwise) to increase material flow.
Fan Pattern Adjustment
See Figure 1. The fan pattern regulator (4) adjusts the shape of the spray pattern from
flat to round.
• Rotate the regulator to the right (clockwise) for a round pattern.
•
Rotate the regulator to the left (counter-clockwise) for a flat pattern.
Air Cap Adjustment
See Figure 2. The position of the atomization air cap and the nozzle determines the
orientation of the fan pattern.
1. Loosen the air cap retaining ring.
2. Rotate the air cap to the desired position, hold it in position, then tighten the retaining
ring securely.