Prodigy
r
Robot Gun
5
Part 1105518
−
02
E
2014
Nordson Corporation
Specifications
Specifications are subject to change without notice.
Electrical Output
Maximum rated output voltage at the electrode
95 kV
10%
Maximum rated output current at the electrode
100
A
10%
Air Pressure and Flow Requirements
Minimum input air
4 bar (60 psi)
Maximum input air
6.9 bar (100 psi)
Pattern air
5.9 bar (85 psi), 6
−
57 l/min. (0.2
−
2.0 scfm)
Temperature Requirement
Maximum ambient temperature
40
_
C (104
_
F)
30
5
Gun
45
5
Gun
90
5
Gun
146 mm
(5.75 in.)
178 mm
(7.01 in.)
217 mm
(8.54 in.)
545 mm
(21.47 in.)
527 mm
(20.75 in.)
422 mm
(16.61 in.)
29 mm
(1.14 in.)
51 mm
(2.01 in.)
28 mm
(1.10 in.)
Figure 3
Gun Dimensions
Air Quality Requirements
Powder spray systems require clean, dry, oil-free
compressed air. Moist or oil-contaminated air can
cause the powder to clog in the pump, powder feed
tubing, or spray gun.
Use 3-micron filter/separators with automatic drains
and a refrigerated or regenerative desiccant-type
air dryer that can produce a 3.4
_
C (38
_
F) or lower
dewpoint at 6.9 bar (100 psi).
Equipment Rating
This applicator is rated for use in a potentially
explosive environment (Class II, Division I Group F
& G or Zone 21).