Corrective Action
Possible Cause
Problem
4. Spray gun fan pattern
changes
Defective pattern air flow control
valve
Clean the pattern air flow control
valve. Refer to
Flow Control Valve
Cleaning
If the problem persists, replace the
pattern air flow control valve. Refer
to
Flow Control Valve Replacement
5. Powder inside spray
gun inlet adapter
Internal nozzle O-ring worn
Replace the internal nozzle O-ring.
Powder delivery hose not seated
properly in tubing adapter
Loosen the retaining nut to remove
the nozzle and retaining nut
assembly.
Pull the tubing adapter from the end
of the flexible powder tube.
Loosen the lock knob and gently pull
the flexible powder tubing out of the
spray gun adapter. Clean the
surfaces.
If the end of the feed tubing is
damaged, cut the damaged end off
with a tube cutter.
Remove the set screw and inlet
adapter from the spray gun. Blow the
adapter and powder tube clean.
Install the inlet adapter. Feed the
flexible powder tubing through the
inlet adapter. Tighten the lock knob.
Install the tubing adapter on the tube
then gently pull the tube back until
the adapter stops against the flange.
Install the nozzle and retaining ring.
6. Air leaking around
end cap
Multiplier gasket worn
Replace the multiplier gasket.
7. Powder tubing too
stiff
Spiral wrap too close to the spray
gun
Remove any spiral wrap that is within
24 in. of the spray gun handle.
8. “Fingers” in spray
pattern
Pattern air setting too low
Increase the pattern air setpoint.
Nozzle plugged
Remove the nozzle, disassemble,
and clean.
Input air pressure too low
Increase the input air pressure.
Calibration constants incorrect
Verify that the calibration constants
on the manifold match what is
entered in the manual spray gun
controller.
Continued...