Prodigy HDLV Generation II Pump, Pump Manifold, and Circuit Board
14
Part 1081195-11
E
2018
Nordson Corporation
Pump Assembly
CAUTION:
Follow the assembly order and specifications shown. Pump damage may occur if you
do not carefully follow the assembly instructions.
NOTE:
Upper and lower Y manifolds intended for repeated contact with food must be thoroughly cleansed
prior to their first use. However, do not clean the porous fluidizing tubes.
1
2
Refer to
Pinch Valve Replacement
on page 16 for specific instructions.
Top
Bottom
3
CAUTION:
Stop
tightening when
the pinch valve
manifold contacts
the lower
manifold body.
Then torque
screws as
described below.
1
2
3
4
Tighten screws two
turns at a time using
an alternating
pattern until pinch
valve manifold
contacts the lower
Y manifold. Once in
contact with lower
Y manifold, torque
each screw to
20
−
25 in-lb.
4
5