Prodigy HDLV Generation II Pump, Pump Manifold, and Circuit Board
27
Part 1081195-11
E
2018
Nordson Corporation
Air and Powder Tubing Connections
See Figure 26 for a description of the air and powder tubing connections for the pump and manifold.
NOTE:
One circuit board may control up to two pumps. The transducer air fittings on the circuit board are
pump-specific: XDCR1 and XDCR2 are for pump 1; XDCR3 and XDCR4 are for pump 2.
Item
Tubing
Function
Item
Tubing
Function
A
10 mm
Blue
From Purge Air Source
(Line Air Pressure)
G
10 mm
Blue
Pump Assist/Pattern Air
Flow Control
5.9 bar (85 psi)
B
8 mm
Clear
Powder Delivery
to Spray Gun
H
6 mm
Blue
Spray Gun Pattern Air
Flow Control (out to gun)
C
8 mm
Clear
Powder Suction
from Feed Source
1
2
−
4 mm
Clear
Pump 1 Pattern Air
Pressure Transducer
D
8 mm
Clear
Pinch Valve Air Pressure
2.0
−
2.75 bar (30
−
40 psi)
3
4
−
4 mm
Clear
Pump 2 Flow Air
Pressure Transducer
E
10 mm
Blue
Vacuum Air Generator
Supply 3.45 bar (50 psi)
5
6
−
4 mm
Clear
Pump 2 Pattern Air
Pressure Transducer
F
10 mm
Blue
Vacuum Generator Vent
7
8
−
4 mm
Clear
Pump 2 Flow Air
Pressure Transducer
4
Top of Manifold
Bottom of Manifold
D
E
F
H
B
C
A
A
6
2
or
5
1
or
7
3
or
8
or
G
Figure 26 Powder and Air Tubing Connections