Nordson Sealant Equipment PRO-METER V2K Скачать руководство пользователя страница 1

 
 
 
 
 
 
 
 
 
 

 

    

     

    

PRO-METER®

 

V2K

 

              

 

 

       

                                                

CUSTOMER PRODUCT MANUAL 

      

                                               

 

COMPONENT MANUAL P/N: 

74

4

02

74

       

                                                  

ISSUED 

/

201

7

 

 

 

 

 

 

For parts and technical support, call the Nordson Sealant Equipment customer support at 
(734) 459-8600, or contact your local Nordson Sealant Equipment Representative.

 

 

This document is subject to change without notice. 

Please check with customer service for the latest version. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nordson Sealant Equipment

٠

Plymouth, Michigan

٠

U.S.A

 

Содержание PRO-METER V2K

Страница 1: ...al support call the Nordson Sealant Equipment customer support at 734 459 8600 or contact your local Nordson Sealant Equipment Representative This document is subject to change without notice Please c...

Страница 2: ...which is protected by copyright Original copyright date 08 2016 No part of this document may be photocopied reproduced or translated to another language without the prior written consent of Nordson C...

Страница 3: ...ogenated Hydrocarbon Solvent Hazards 1 6 Action in the Event of a Malfunction 1 6 Disposal 1 6 Description 2 1 Meter 2 1 Meter Assembly Standard Components 2 2 Meter Connections 3 1 Connection Overvie...

Страница 4: ...scriptions 7 2 Auto Flow Mode 7 2 Auto Shot Mode 7 2 Manual Flow Mode 7 2 Manual Shot Mode 7 2 Operation 7 3 Maintenance 8 1 Consumables 8 2 Preparation For Maintenance and Service 8 3 Air Pressure Re...

Страница 5: ...c Valve Manifold 10 35 Removal 10 35 Installation 10 37 Pneumatic Valve Manifold Solenoid 10 38 Removal 10 38 Installation 10 39 Power Supply Fuse 10 40 Removal 10 40 Installation 10 42 Power Supply C...

Страница 6: ...ispense 1 14 2 Dispense 2 14 3 Faults Warnings 1 and 2 14 4 Faults Warnings 1 14 4 Faults Warnings 2 14 5 Interlock Status 14 7 Material Pressure 14 8 Material Pressure History 14 9 Meter Status 14 10...

Страница 7: ...2 Customer Product Manual 15 3 Pro Meter V2K Assembly Top Level Assembly 15 3 Pro Meter V2K Basic Assembly 15 6 Base Plate Assembly 15 16 Cover Assembly 15 21 Gravity Feed Tanks If Equipped 15 23 HMI...

Страница 8: ......

Страница 9: ...afety rules and regulations and are physically capable of performing their assigned tasks Intended Use Use of Nordson equipment in ways other than those described in the documentation supplied with th...

Страница 10: ...t While operating manual dispense valves make sure you are grounded Wear electronically conductive gloves or a grounding strap connected to the dispense valve handle or other true earth ground Do not...

Страница 11: ...ous traumatic injury It is important to treat the injury surgically as soon as possible Do not delay treatment to research toxicity Toxicity is a concern with some exotic coatings injected directly in...

Страница 12: ...tions of volatile materials or vapors Refer to local codes or your SDS for guidance Do not disconnect live electrical circuits while working with flammable materials Shut off power at a disconnect swi...

Страница 13: ...eing evaluated Equipment to be grounded includes but is not limited to the floor of the spray area operator platforms hoppers photoeye supports and blow off nozzles Personnel working in the spray area...

Страница 14: ...erial SDS or contact your material supplier for more information If you must use halogenated hydrocarbon solvents contact your Nordson Sealant representative for information about compatible Nordson S...

Страница 15: ...nts consist of an air actuator ball valve assemblies metering cartridge assemblies power supply assembly valve manifold micro PLC and an interactive HMI control panel Each metering cartridge assembly...

Страница 16: ...charge port where it is later dispensed via a dispense valve 3 Ball valve serves as the inlet valve for the dispense system 4 Metering cartridge assembly metering rods along with associated seals and...

Страница 17: ...Refer to Maintenance Preparation For Maintenance And Service page 8 3 for additional information Apply Loctite properly to fasteners Refer to Thread Locker Application page 5 2 for Loctite applicatio...

Страница 18: ...e as this may cause material to pack and harden Only apply removable thread locker and sealant as specified by the procedures in this manual Electrical Harness Connectors Connect electrical harness co...

Страница 19: ...metering cartridge assembly primary seal Material ob served from the weep plug denotes metering cartridge assembly primary seal failure 7 Metering cylinder housing oil cup allows Seal Sav r oil to be...

Страница 20: ......

Страница 21: ...troke 5 50 inch 139 7 mm Micro PLC Refer to Product Literature Pneumatic valve Manifold Refer to Product Literature System decibels maximum 63 6 dBA System dimensions 30 38 inches 771 65 mm long x 17...

Страница 22: ......

Страница 23: ...e properly to fasteners Refer to Loctite Product Application Cleanup And Storage page 5 2 for Loctite application information WARNING Any material injected into flesh can cause severe injury or death...

Страница 24: ...ld be allowed to run down the internal threads until it reaches the bottom of the blind hole Product sets in approximately 10 minutes and cures in 24 hours Sealing Applications Ensure the work area is...

Страница 25: ...5 3 Part 7440274 2017 Nordson Corporation Storage Ensure container holding product is completely sealed after use Do not allow product to freeze Store product in a dry location Optimal storage tempera...

Страница 26: ......

Страница 27: ...tion page 5 1 for Loctite application information Clean any material that has spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spilled material Refer to Safet...

Страница 28: ...without the gravity tanks installed 31 51 inches 800 35 mm tall with the gravity tanks installed Air Line Routing Refer to the Pneumatic Circuit Drawing s for air line routing information Ensure air l...

Страница 29: ...en captures 1 Connect discharge port hoses to the metering cartridge assemblies Discharge port hoses connect to both sides of the dispense system Discharge port hose Figure 6 3 Discharge Port Hose Con...

Страница 30: ...egulator assembly 6 Switch Pro Meter V2K power switch to the ON position 7 Proceed to Main Menu HMI Pendant Screen 8 Select SETUP LOGIN push button to proceed to Setup Login HMI Pendant screen 9 Log i...

Страница 31: ...ir bubbles are no longer observed in the clear tubing 15 Close bleed valves located on the metering cartridge assemblies 16 Proceed to the Dispense 1 HMI Pendant Screen and note the following Select M...

Страница 32: ...roceed to Level 2 Setup HMI Pendant Screen Select RESET PASSWORD to proceed to Reset Password HMI Pendant Screen Select Reset Password push button and follow prompts Air Actuator Flow Adjustment See F...

Страница 33: ...llowing Enter the Scaled Distance mm valve into the 0 mm Cal Value mA data entry field Proceed to Valve Setup HMI Pendant screen See Step 2 Press the Return Rods push button so that the meter is fully...

Страница 34: ...bration in instances where there is an extreme difference in viscosity regarding materials Adjustment of lead lag calibration optimizes the mix of material 1 Loosen lead lag jam nut 2 2 Adjust lead la...

Страница 35: ...evel sensors 1 Utilize a small flat head screw driver to gently pry open low level sensor adjustment screw access cover B 2 Turn low level sensor adjustment screw A slowly counter clockwise with a sma...

Страница 36: ...on the pressure transducer 2 Utilize calibration record as a basis to enter control panel calibration data 3 Turn control panel OFF 4 Install new pressure transducer Refer to Removal and Installation...

Страница 37: ...OTE Refer to Screen Descriptions page 14 1 to review illustrative screen captures 1 Proceed to the Dispense 1 HMI Pendant Screen 2 Select Manual Mode push button 3 With the primary cover removed adjus...

Страница 38: ...Corporation Strike stop contacts limit switch Figure 6 10 Meter Empty Position 4 Turn OFF Manual Mode via the Dispense 1 HMI Pendant Screen 5 Adjust the strike stop position via the strike screw nut u...

Страница 39: ...d environmental guidelines when cleaning spilled material Refer to Safety page 1 1 for additional information WARNING Any material injected into flesh can cause severe injury or death Keep body parts...

Страница 40: ...eload as long as a signal is received from the external source Auto Shot Mode Auto Shot Mode accommodates the completion of several automated dispense shots and reloads as dictated by the shot counter...

Страница 41: ...I Pendant Screen and enable the Machine Interlock Mode push button 7 From the Level 1 Setup Menu HMI Pendant Screen establish the following parameters System delay specifications via the Miscellaneous...

Страница 42: ......

Страница 43: ...Loctite application information Clean any material that has spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spilled material Refer to Safety page 1 1 for ad...

Страница 44: ...per Blu 7437105 Applied to slide block zerk fittings to lub ricate slide rail Refer to Maintenance Preventative Maintenance Schedule page 8 5 for additional information Loctite 242 N A Apply when proc...

Страница 45: ...itting from filter regulator assembly air input port 1 located on power supply assembly 1 Figure 8 11 Quick Connect Air Fitting 3 Remove the secondary cover 2 from the primary cover 1 CAUTION Utilize...

Страница 46: ...e screws located at the center of the pneumatic valve manifold solenoid See Figure 8 13 7 Slightly lift pneumatic valve manifold solenoid middle 1 to allow air to escape See Figure 8 13 1 Figure 8 13...

Страница 47: ...uidelines when cleaning spilled material Refer to Safety page 1 1 for additional information 3 Monitor pressure transducer readings via teach pendant HMI to verify that system material pressure is at...

Страница 48: ...anks Inspect for material leaks Inspect 5 Min Replace 30 Min Guide rod Inspect for scoring and straightness Inspect 15 Min Replace 30 Min Material fittings and hoses Inspect for material leaks Inspect...

Страница 49: ...ation Table 8 5 Preventative Maintenance Schedule contd Strike screw Inspect for straightness debris damage to threads Inspect 15 Min Replace 1 2 Hrs Pneumatic valve mani fold Inspect for air leaks fr...

Страница 50: ......

Страница 51: ...Loctite application information Clean any material that has spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spilled material Refer to Safety page 1 1 for add...

Страница 52: ...ufficient air pressure Ensure solenoid valves are functioning properly Metering cartridge assembly malfunction Check for sufficient supply pressure Inspect wearable parts for wear and damage Inspect m...

Страница 53: ...page 5 1 for Loctite application information Clean any material that has spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spilled material Refer to Safety pa...

Страница 54: ...s spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spilled material Refer to Safety page 1 1 for additional information 1 Remove metering cartridge assemblies...

Страница 55: ...c valve manifold See Figure 10 43 Be careful not to kink or otherwise damage electrical wiring harness 5 Remove cap screws securing air valve control shelf to strike end bracket 6 Carefully pivot air...

Страница 56: ...ike end bracket Remove washer from strike end screw if necessary Utilize pick or equivalent tool to remove bushing from strike end bracket if necessary CAUTION Do not reuse bushing 9 Utilize an adjust...

Страница 57: ...alve 1 from air actuator if necessary NOTE It is possible to remove the flow control valve and flow control valve bushing from the air actuator as an assembly 1 1 Figure 10 14 Flow Control Valve Assem...

Страница 58: ...or into metering cylinder housing by hand until air actuator rod is snug with the carriage Loosely install and then tighten socket head cap screws securing air actuator to metering cylinder housing in...

Страница 59: ...ovable thread locker to air actuator rod threads Apply Loctite 242 or 248 or equivalent removable thread locker to threads of socket head cap screws securing strike end bracket to base plate Apply Loc...

Страница 60: ...her related documentation Clean any material that has spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spilled material Refer to Safety page 1 1 for additiona...

Страница 61: ...n Corporation 5 Remove bolts and lock washers securing ball valve to ball valve assembly Figure 10 16 Removal Of Ball Valve From Ball Valve Assembly 6 Remove ball valve 1 from ball valve flange 2 1 2...

Страница 62: ...Closed ball valve is denoted by the indicator positioned horizontally Figure 10 18 Ball Valve Depicted In Closed Position 7 Remove air fittings from ball valve if necessary 8 Unscrew ball valve flange...

Страница 63: ...install socket head screws securing primary cover to primary cover bracket LH RH and then tighten until they are snug Hand tighten air fittings so that they are snug if removed CAUTION Ensure the ball...

Страница 64: ...al guidelines when cleaning spilled material Refer to Safety page 1 1 for additional information 1 Remove air actuator Refer to Removal and Installation Air Actuator page 10 2 for air actuator removal...

Страница 65: ...et head cap screws and tighten in a criss cross pattern to 13 5 N m 10 0 ft lb Loosely install carriage hard stop socket head cap screws and tighten in a criss cross pattern to 13 5 N m 10 0 ft lb CAU...

Страница 66: ...sure to follow all applicable safety and environmental guidelines when cleaning spilled material Refer to Safety page 1 1 for additional information 1 Remove metering cartridge assembly Refer to Remov...

Страница 67: ...ote the following Hand tighten fasteners securing cylinder position sensor brackets to air actuator so that they are snug CAUTION Be careful not to damage cylinder position sensor Do not reuse damaged...

Страница 68: ...ure to follow all applicable safety and environmental guidelines when cleaning spilled material Refer to Safety page 1 1 for additional information 1 Place ball valve located just below gravity tank i...

Страница 69: ...1 2 Figure 10 24 Gravity Tank Removal From Gravity Tank Bracket 5 Remove locking pins 1 from cam lock coupling 1 Figure 10 25 Locking Pin Removal From Cam Lock Coupling 6 Release the cam lock coupling...

Страница 70: ...sensor if equipped Refer to Removal and Installation Low Level Sensor page 10 26 for low level sensor removal procedure Installation Installation of the gravity tank is in the reverse order of remova...

Страница 71: ...e safety instructions in this document and all other related documentation Clean any material that has spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spille...

Страница 72: ...imit switch mount Installation Installation of limit switch is in the reverse order of removal Note the following Loosely install limit switch socket head cap screws and tighten to 1 7 N m 15 6 in lb...

Страница 73: ...ment and all other related documentation Clean any material that has spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spilled material Refer to Safety page 1...

Страница 74: ...it switch mount Installation Installation of limit switch is in the reverse order of removal Note the following Loosely install limit switch socket head cap screws and tighten to 1 7 N m 15 6 in lb Lo...

Страница 75: ...cumentation Clean any material that has spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spilled material Refer to Safety page 1 1 for additional information...

Страница 76: ...moval From Linear Speed Control 4 Unscrew linear speed control from metering cylinder housing 5 Utilize channel locks or equivalent tool to loosen linear speed control bushing Figure 10 33 Linear Spee...

Страница 77: ...of removal Note the following Hand tighten linear speed control bushing until it is snug Hand tighten linear speed control until it is snug Install gravity tank bracket to air actuator socket head ca...

Страница 78: ...plicable safety and environmental guidelines when cleaning spilled material Refer to Safety page 1 1 for additional information 1 Disconnect electrical harness connector from low level sensor CAUTION...

Страница 79: ...ted documentation Clean any material that has spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spilled material Refer to Safety page 1 1 for additional inform...

Страница 80: ...primary cover to primary cover bracket LH RH 3 Remove primary cover from dispense system 4 Disconnect electrical harness connector from pressure transducer if equipped CAUTION Do not kink or otherwis...

Страница 81: ...metering rod 1 Figure 10 38 Metering Rod Collar Removal From Metering Rod Remove metering rod mounting collar from metering rod NOTE Remove the metering rod mounting collar in halves 7 Remove socket...

Страница 82: ...cartridge assembly is in the reverse order of removal Note the following Tighten metering cartridge assembly socket head cap screws to 13 5 N m 10 0 ft lb Hand tighten plug so that it is snug if remov...

Страница 83: ...loosen lead lag nut to facilitate installation of metering rod collar Figure 10 41 Metering Rod Collar Installation CAUTION Apply Loctite 577 or equivalent thread sealer to threads of reducer plug an...

Страница 84: ...uctions in this document and all other related documentation Clean any material that has spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spilled material Ref...

Страница 85: ...lease it from Micro PLC Figure 10 43 Removal Of Options Harness Block From Micro PLC 5 Remove Ethernet cable from micro PLC 6 Utilize screwdriver or equivalent to release green terminal blocks from ea...

Страница 86: ...tion Installation of micro PLC is in the reverse order of removal Note the following Hand tighten green terminal block screws until they are snug Loosely install socket head screws securing primary co...

Страница 87: ...uctions in this document and all other related documentation Clean any material that has spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spilled material Ref...

Страница 88: ...e located on the underside of the air valve control shelf Pivot the air valve control shelf upwards if necessary to access nuts and lock washers Proceed as follows Disconnect air lines and green termi...

Страница 89: ...r valve control shelf 3 and then tighten in a criss cross pattern to 3 9 N m 34 8 in lb Loosely install air valve control shelf bracket to strike end plate cap screws and then tighten to 13 5 N m 10 0...

Страница 90: ...safety instructions in this document and all other related documentation Clean any material that has spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spilled...

Страница 91: ...tic valve manifold solenoid Figure 10 47 Removal Of Pneumatic Valve Solenoid 1 of 2 Figure 10 48 Removal Of Pneumatic Valve Solenoid 2 of 2 Installation Installation of the pneumatic valve manifold so...

Страница 92: ...following tasks Follow the safety instructions in this document and all other related documentation Clean any material that has spilled Be sure to follow all applicable safety and environmental guide...

Страница 93: ...ion 10 41 Part 7440274 2017 Nordson Corporation Figure 10 50 Fuse Removal From Power Supply Switch 2 of 4 Figure 10 51 Fuse Removal From Power Supply Switch 3 of 4 Figure 10 52 Fuse Removal From Power...

Страница 94: ...Removal and Installation 10 42 Part 7440274 2017 Nordson Corporation Installation Installation of the power supply fuse is in the reverse order order of removal...

Страница 95: ...cable safety and environmental guidelines when cleaning spilled material Refer to Safety page 1 1 for additional information 1 Remove the secondary cover 2 from the primary cover 1 CAUTION Utilize han...

Страница 96: ...Supply Cover Removal 2 of 2 Installation Installation of power supply cover is in the reverse order of removal Note the following Loosely install socket head cap screws lock washers and nuts securing...

Страница 97: ...ing tasks Follow the safety instructions in this document and all other related documentation Clean any material that has spilled Be sure to follow all applicable safety and environmental guidelines w...

Страница 98: ...f removal Note the following Loosely install socket head cap screws lock washers washers and nuts securing power supply cover to power supply and tighten to 1 7 N m 15 6 in lb CAUTION Apply Loctite 24...

Страница 99: ...er to Safety page 1 1 for additional information 1 Remove power supply cover Refer to Removal and Installation Power Supply Cover page 10 40 for power supply cover removal procedure 2 Remove socket he...

Страница 100: ...t has spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spilled material Refer to Safety page 1 1 for additional information 1 Disconnect electrical harness co...

Страница 101: ...y port securing pressure transducer with Chevron Petrolatum Snow Do not attempt to scrape hardened material from the pressure transducer Attempting to remove hardened material may result in component...

Страница 102: ......

Страница 103: ...page 5 1 for Loctite application information Clean any material that has spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spilled material Refer to Safety pa...

Страница 104: ...20 19 17 16 18 15 Figure 11 59 Metering Cartridge Assembly Exploded View 1 Metering rod 8 Cap 15 Nut 2 Socket head cap screws 9 Seal 16 O ring 3 O ring 10 O ring 17 Parbak ring 4 Rod oil retainer 11...

Страница 105: ...ment and all other related documentation Clean any material that has spilled Be sure to follow all applicable safety and environmental guidelines when cleaning spilled material Refer to Safety page 1...

Страница 106: ...2 3 4 Figure 11 60 Removal Of Base From Tube 4 Utilize a plastic pick with a blunt tip or equivalent tool to remove O ring 2 and Parbak ring 3 from metering cylinder base 1 1 2 3 Figure 11 61 O ring...

Страница 107: ...4 from tie rods 1 See Figure 11 62 7 Remove tube 2 from metering cylinder body 3 See Figure 11 62 8 Utilize a plastic pick with a blunt tip or equivalent tool to remove Parbak ring 1 and O ring 2 fro...

Страница 108: ...ing retainer 3 Figure 11 64 Removal Of Oil Retainer To Bearing Retainer Fasteners 10 Remove metering rod 2 from metering cartridge assembly 1 1 2 Figure 11 65 Removal Of Metering Rod From Metering Car...

Страница 109: ...with a blunt tip or equivalent tool to remove O ring 1 from rod oil retainer 2 CAUTION Do not use sharp or pointed tools to remove O ring Do not reuse O ring 1 2 3 Figure 11 67 Removal Of O rings From...

Страница 110: ...etering Cylinder Body CAUTION Utilize a spanner wrench or equivalent tool to unscrew bearing retainer from metering cylinder body 15 Utilize a plastic pick with a blunt tip or equivalent tool to remov...

Страница 111: ...antern ring from metering cylinder body 1 2 Figure 11 71 Lantern Ring Removal From Metering Cylinder Body 18 Utilize a plastic pick with a blunt tip or equivalent tool to remove O ring 1 from lantern...

Страница 112: ...or pointed tools to remove seal Do not reuse seal 21 Utilize a plastic pick with a blunt tip or equivalent tool to remove O ring 5 from lantern ring 4 See Figure 11 72 CAUTION Do not use sharp or poi...

Страница 113: ...o metering cylinder body so that they are snug Loosely install nuts 15 and tighten to 13 5 N m 10 0 ft lb See Figure 11 59 Hand tighten bearing retainer until it is snug CAUTION Do not reuse bearings...

Страница 114: ...ill contact nuts and metering cylinder body The surface of the metering rod is ground to specification and should be protected from damage during handling Utilize a spanner wrench or equivalent tool t...

Страница 115: ...els 800x480 WVGA Type TFT touchscreen wide LCD ELECTRICAL Communication port Separate RS232 and RS422 RS485 connectors Ethernet 10 100 Mbps 1 Internal Storage 256 MB Programming port USB device port E...

Страница 116: ...on Table 12 6 PanelView C800 Specifications contd MECHANICAL Accessories 7 inch adapter plate kit part 2711R APK7 Cutout dimensions 4 9x7 1 125 x 179 mm Mounting mechanism Quick lever clips Overall di...

Страница 117: ...an option that has not been selected for the particular application Push Buttons See Figure 13 77 Push buttons are shown as raised rectangular objects containing text General operational control butt...

Страница 118: ...a data entry push button on the screen will open a pop up keypad that will allow the operator to enter new data given preset limits defined by the PLC Pressing the ENTER key on the keypad will complet...

Страница 119: ...Common Screen Description Elements 13 3 Part 7440274 2017 Nordson Corporation Pilot light indicator Figure 13 76 Pilot Light Indicator Example...

Страница 120: ...Common Screen Description Elements 13 4 Part 7440274 2017 Nordson Corporation Push button Figure 13 77 Push button Example...

Страница 121: ...Common Screen Description Elements 13 5 Part 7440274 2017 Nordson Corporation Push button with indicator light Figure 13 78 Push Button With Indicator Light Example...

Страница 122: ...Common Screen Description Elements 13 6 Part 7440274 2017 Nordson Corporation Data display Figure 13 79 Data Display Example...

Страница 123: ...Common Screen Description Elements 13 7 Part 7440274 2017 Nordson Corporation Data entry field Figure 13 80 Data Entry Field Example...

Страница 124: ...Common Screen Description Elements 13 8 Part 7440274 2017 Nordson Corporation Dashboard indicator Figure 13 81 Dashboard Indicator Example...

Страница 125: ...Common Screen Description Elements 13 9 Part 7440274 2017 Nordson Corporation Bar graph Figure 13 82 Bar Graph Example...

Страница 126: ...s are located along the bottom of the screen On normal operation screens the button to return to the Main Menu screen is usually found in the lower right corner On most setup screens this position is...

Страница 127: ...Common Screen Description Elements 13 11 Part 7440274 2017 Nordson Corporation Mode indicator Status indicator Title bar Navigation Button Figure 13 83 Typical Screen Layout...

Страница 128: ......

Страница 129: ...gate to any screen The indicator at the top left of the screen is the mode indicator If no mode is selected the box will appear grey with No Mode text displayed The box will appear yellow while in Aut...

Страница 130: ...eloading Dispensing Complete Purging are also present This screen also has push buttons to engage Auto Shot Mode Dispense and Reload Data displays are also present reflecting high and low volume psi A...

Страница 131: ...psi and the time remaining until a purge is initiated A shot counter data display is present along with bar graphs to reflect system full empty status cylinder position and material pressure A push bu...

Страница 132: ...p indicates that the Emergency Stop button on the control panel has been depressed To reset the system release the Emergency Stop button and press the Reset Faults navigation button on the Faults Warn...

Страница 133: ...sure faults in the system Note the following High Pressure is a fault indicating that the observed pressure exceeds the high pressure limit Low Dispense Pressure is a fault indicating that the observe...

Страница 134: ...orporation Resets faults Directs operators to the Faults Warnings 1 Screen Directs operators to the Main Menu Screen System indicators reflect different faults and warnings which could occur during op...

Страница 135: ...operator to troubleshoot the system The inputs from the operator to the machine are OK to Purge Dispense Command and Reload Command The outputs from the machine to the operator are Dispense Ready Dis...

Страница 136: ...will fault and stop the system if the pressure drops below the programmed limit during an active dispense cycle The Reload Limit must be met or exceeded before the pre pressure sequence can begin The...

Страница 137: ...ssure data boxes record the highest and lowest pressures for respective sides of the meter Recorded pressures can be reset to 0 psi and re recorded until they are reset again The status indicators alo...

Страница 138: ...tatus of inputs outputs and options These areas illuminate when each valve switch or sensor is activated This screen is primarily used as a troubleshooting tool Directs operators Directs operators to...

Страница 139: ...ent options These options control several parts of the system It is important to note that selecting various options only configures the PLC and operator interface software for these options Additiona...

Страница 140: ...nitiate the purge cycle by pressing the Manual Purge push button or clear the nozzle by initiating any other dispensing operation If for some reason the nozzle is not purged before the purge timer rea...

Страница 141: ...etup and Level 2 Setup Screens This interface also allows the operator to log in and out Directs operators to the Level 1 Setup Screen Directs operators to the Level 2 Setup Screen Directs operators t...

Страница 142: ...assword Confirm Exit To Config Mode See Figure 14 96 This screen allows the operator the option of either exiting to configuration mode or navigating back to the Level 2 Setup Screen Directs operators...

Страница 143: ...14 97 This screen allows the operator to specify the metering cartridge assembly tube diameter This screen also displays the amount of material dispensed per shot Directs operators to Level 1 Setup S...

Страница 144: ...This screen has a push button with an indicator light to denote Flow Mode Auto Retract Enable There is also a data entry field for operators to specify the Auto Reload Delay sec Directs operators to M...

Страница 145: ...es of the dispense system The Dispense Ready Dispense Complete and Purge Warning push buttons all send signals to the automation source The push buttons are accompanied by indicators to confirm a sign...

Страница 146: ...t 7440274 2017 Nordson Corporation Level 1 Setup Menu See Figure 14 100 Push buttons navigate the operator to other screens This screen accommodates easy navigation to other screens Figure 14 100 Leve...

Страница 147: ...t 7440274 2017 Nordson Corporation Level 2 Setup Menu See Figure 14 101 Push buttons navigate the operator to other screens This screen accommodates easy navigation to other screens Figure 14 101 Leve...

Страница 148: ...to specify the length in time that the machine waits before sending a signal to the automation source Delays may established for the following Cylinder Extend Cylinder Retract Direction Change Dispens...

Страница 149: ...rent options These options control several parts of the system It is important to note that selecting various options only configures the PLC and operator interface software for these options Addition...

Страница 150: ...then show the calibrated distance with no correction for the zero offset The displayed distance may be positive or negative due to the pre load placed on the cylinder position sensor when it is instal...

Страница 151: ...and the dispense cycle will stop This helps guard against leaks broken hoses etc Reload Pressure Limit psi During a reload cycle the inlet valve will stay open until the carriage reaches its home pos...

Страница 152: ...Screen Descriptions 14 24 Part 7440274 2017 Nordson Corporation Directs operators to Misc Pressure Screen Directs operators to Level 1 Setup Screen Figure 14 105 Pressure Limits Setup HMI Interface...

Страница 153: ...ield Enter the appropriate calibration values from the Certificate of Calibration for that transducer into the 0 psi Cal mA and Full Scale psi Cal value ma interface entry fields The Scaled Pressure a...

Страница 154: ...ies scaled pressure for high and low volume side of the meter Allows entry of pres sure sensor full scale psi Allows entry of psi cal value Allows entry of the full scale psi cal val mA Allows zero of...

Страница 155: ...se Pressure Fault Duration sec A push button has been conveniently provided to allow operators to illustrate pressure readings in PSI or BAR Specification of these values directly impacts the info gra...

Страница 156: ...r of shots per purge the purge warning time and purge fault time The Purge Warning Time is the time period the machine will wait before a purge warning signal is generated The Purge Fault Time is the...

Страница 157: ...allows the operator to update passwords Operators are able to customize passwords for level 1 and level 2 screen access The default user name is 2 The default password is also 2 Directs operators to L...

Страница 158: ...specify the Shot Per Cycle Retract Pos mm and Extend Pos mm The entry of position location data allows the PLC to display calculated volume output when a cylinder position sensor is not utilized Dire...

Страница 159: ...ng Overrides are deactivated whenever the operator leaves this screen The dispense valve must be open when advancing the air cylinder to allow metered material to flow Allowing material to flow will p...

Страница 160: ......

Страница 161: ...ns the part cannot be ordered separately The Description column gives the part name as well as its dimensions and other characteristics when appropriate Indentions show the relationships between assem...

Страница 162: ...ote 0000000 Assembly 1 1 000000 S Subassembly 2 A 2 000000 S S Part 1 Item Part Description Quantity Note S S S S S S S S S S NOTE A B X AR As Required NS Not Shown Continued 3 Column Parts List Part...

Страница 163: ...CHT DWG TOP LVL ASSY PRO MTR V2K 1 10 7440581 S ASSEMBLY BASIC PRO MTR V2K 1 20 7440519 S CARTRIDGE MTR ASSY 250 PM V2K AA 1 30 7440518 S CARTRIDGE MTR ASSY 1 125 PM V2K AA 1 40 7440515 S COVER ASSY...

Страница 164: ...Parts 15 4 Part 7440274 E 2017 Nordson Corporation 2600 163 XXX 80 10 Figure 15 112 Pro MeterR Top Level Assembly 1 of 2...

Страница 165: ...Parts 15 5 Part 7440274 E 2017 Nordson Corporation 2600 163 XXX 50 30 10 70 70 20 50 Figure 15 113 Pro MeterR Top Level Assembly 2 of 2...

Страница 166: ...POWER SUPPLY 24VDC ASSY PRO MTR V2K 1 19 7430948 S REDUCER 1 2IN M X 3 8IN F 2 20 1607012 S CYLINDER AIR 100MM BORE X 144MM STK 1 21 7436106 S SCREW BHC M5X0 8X15MM 2 22 7436107 S SCREW BHC M6X1X12MM...

Страница 167: ...12 55 7436652 S SCREW SHC BL OX M6X40 4 56 7440275 S VALVE SLND 3 STA D SUB PM VE 1 57 7440528 S BELLOWS LINEAR SLIDE 25MMX330MM 1 58 7440529 S LINEAR SLIDE SYSTEM 25MMX330MM 1 59 7430419 S CONNECTOR...

Страница 168: ...Parts 15 8 Part 7440274 E 2017 Nordson Corporation 1700 070 000 18 15 36 42 Figure 15 114 Pro MeterR Basic Assembly 1 of 8...

Страница 169: ...Parts 15 9 Part 7440274 E 2017 Nordson Corporation 1700 070 000 22 25 14 Figure 15 115 Pro MeterR Basic Assembly 2 of 8...

Страница 170: ...Parts 15 10 Part 7440274 E 2017 Nordson Corporation 1700 070 000 18 51 59 60 1 66 67 8 31 9 10 50 25 54 65 64 Figure 15 116 Pro MeterR Basic Assembly 3 of 8...

Страница 171: ...Parts 15 11 Part 7440274 E 2017 Nordson Corporation 1700 070 000 62 63 61 57 58 Figure 15 117 Pro MeterR Basic Assembly 4 of 8...

Страница 172: ...Parts 15 12 Part 7440274 E 2017 Nordson Corporation 1700 070 000 19 38 20 44 24 51 22 49 14 37 16 21 23 27 34 26 33 47 56 Figure 15 118 Pro MeterR Basic Assembly 5 of 8...

Страница 173: ...Parts 15 13 Part 7440274 E 2017 Nordson Corporation 2600 163 001 6 5 32 41 29 Figure 15 119 Pro MeterR Basic Assembly 6 of 8...

Страница 174: ...Parts 15 14 Part 7440274 E 2017 Nordson Corporation 1700 070 000 11 45 40 11 39 4 Figure 15 120 Pro MeterR Basic Assembly 7 of 8...

Страница 175: ...Parts 15 15 Part 7440274 E 2017 Nordson Corporation 1700 070 000 6 43 30 5 Figure 15 121 Pro MeterR Basic Assembly 8 of 8...

Страница 176: ...VE AL CAST MCHING 1 2 7440402 S HOUSING MTR CYL PM VE AL CAST MCHNG 1 3 7440513 S ANGLE CVR MNT 13 5 IN SHMET PRO MTR V2K 1 4 7440514 S ANGLE CVR MNT 19 5 IN SHMET PRO MTR V2K 1 5 7440534 S INSERT TH...

Страница 177: ...Parts 15 17 Part 7440274 E 2017 Nordson Corporation 1700 050 004 1 8 3 4 Figure 15 122 Base Plate Assembly 1 of 4...

Страница 178: ...Parts 15 18 Part 7440274 E 2017 Nordson Corporation 1700 050 004 2 9 Figure 15 123 Base Plate Assembly 2 of 4...

Страница 179: ...Parts 15 19 Part 7440274 E 2017 Nordson Corporation 1700 050 004 5 Figure 15 124 Base Plate Assembly 3 of 4...

Страница 180: ...Parts 15 20 Part 7440274 E 2017 Nordson Corporation 1700 050 004 6 5 7 Figure 15 125 Base Plate Assembly 4 of 4...

Страница 181: ...15 COVER ASSY MN PLSTC 2 PC PRO MTR V2K 1 1 7440505 S COVER MN PLSTC 2 PC PRO MTR V2K 1 2 7440506 S CLIP HMI TO COVER SS PRO MTR V2K 2 3 7439443 S WASHER FLAT BL OX 3MMX7MM 4 4 7440754 S PULL RIVET 1...

Страница 182: ...Parts 15 22 Part 7440274 E 2017 Nordson Corporation 1500 073 000 5 Figure 15 127 Cover Assembly 2 of 2...

Страница 183: ...S SCREW SHC BL OX M10X20 4 4 7440511 S BRACKET SPLY TANK 2 5 GAL WLDMNT PRO MTR 1 5 7440525 S COUPLING CAMLOCK 1IN MALE 1IN NPT M SS 2 6 7440526 S COUPLING CAMLOCK 1 IN FEM 1 IN NPT M SS 2 7 7440535 S...

Страница 184: ...Parts 15 24 Part 7440274 E 2017 Nordson Corporation 1700 069 000 4 3 2 9 Figure 15 129 Gravity Feed Tanks 2 of 2...

Страница 185: ...1 3 7440536 S SWITCH ESTOP DPST 29MM 1 4 7440551 S HARNESS WIRING HMI PRO MTR V2K 1 5 7440601 S SCREW SHMET FH NO 6X 625 4 6 7440725 S PLATE HMI GROUND PRO MTR V2K 1 7 7430396 S CONNECTOR LUG COPPER...

Страница 186: ...Parts 15 26 Part 7440274 E 2017 Nordson Corporation 1700 066 00 2 6 7 8 9 Figure 15 131 HMI Pendant 2 of 3...

Страница 187: ...Parts 15 27 Part 7440274 E 2017 Nordson Corporation 1700 066 000 3 2 5 Figure 15 132 HMI Pendant 3 of 3...

Страница 188: ...80 S METERING ROD 1 90 S METERING CYLINDER 1 100 S ROD SEAL HOUSING 1 110 S CAP SEAL HOUSING 2 120 S ROD BEARING 1 130 S ROD OIL RETAINER 1 140 S O RING 1 150 S O RING 2 160 S O RING 1 170 S O RING 1...

Страница 189: ...Parts 15 29 Part 7440274 E 2017 Nordson Corporation 1700 063 DIA 20 210 60 90 30 200 10 40 180 120 70130 180 230 140 80 170 190 100 160 110 150 220 50 Figure 15 133 Metering Cartridge Assembly...

Страница 190: ...M6X1X12MM 3 7 7439442 S SCREW FHC BL OX M3X12 3 8 7439443 S WASHER FLAT BL OX 3MMX7MM 2 9 7436353 S NUT HEX M6X1 3 10 7439165 S WASHER LOCK BL OX 3MMX6 2MM 5 11 7440546 S FITTING AIR BHD BRS 3 8 NPT...

Страница 191: ...Parts 15 31 Part 7440274 E 2017 Nordson Corporation 1700 064 000 5 14 15 18 Figure 15 134 Power Supply Assembly 1 of 3...

Страница 192: ...Parts 15 32 Part 7440274 E 2017 Nordson Corporation 1700 064 000 16 11 4 1 5 7 10 3 2 Figure 15 135 Power Supply Assembly 2 of 3...

Страница 193: ...Parts 15 33 Part 7440274 E 2017 Nordson Corporation 1700 064 000 6 9 12 8 10 13 17 Figure 15 136 Power Supply Assembly 3 of 3...

Страница 194: ...Dia meter mm Hytrel Meter Cartridge Hytrel Soft Re build Kit Hytrel Hard Re build Kit UHMW Meter Cartridge UHMW Soft Re build Kit UHMW Hard Re build Kit Notes 0 250 6 350 7740519 7440665 7740666 77405...

Страница 195: ......

Отзывы: