background image

For Nordson EFD sales and service in over  
40 countries, contact Nordson EFD or go to  
www.nordsonefd.com.

Global 

800-556-3484; +1-401-431-7000 
[email protected]

Europe

 

00800 7001 7001 
[email protected]

Asia

 

China: +86 (21) 3866 9006; [email protected] 
India: +91 80 4021 3600; [email protected] 
Japan: +81 03 5762 2760; [email protected] 
Korea: +82-31-736-8321; [email protected] 
SEAsia: +65 6796 9522; [email protected]

The Wave Design is a trademark of Nordson Corporation. 
©2021 Nordson Corporation    7026881    v012321

NORDSON EFD ONE YEAR LIMITED WARRANTY

This Nordson EFD product is warranted for one year from the date of purchase to be free 
from defects in material and workmanship (but not against damage caused by misuse, 
abrasion, corrosion, negligence, accident, faulty installation, or by dispensing material 
incompatible with equipment) when the equipment is installed and operated in accordance 
with factory recommendations and instructions. 

Nordson EFD will repair or replace free of charge any defective part upon authorized return 
of the part prepaid to our factory during the warranty period. The only exceptions are those 
parts which normally wear and must be replaced routinely, such as, but not limited to, valve 
diaphragms, seals, valve heads, needles, and nozzles.

In no event shall any liability or obligation of Nordson EFD arising from this warranty exceed 
the purchase price of the equipment. 

Before operation, the user shall determine the suitability of this product for its intended use, 
and the user assumes all risk and liability whatsoever in connection therewith. Nordson EFD 
makes no warranty of merchantability or fitness for a particular purpose. In no event shall 
Nordson EFD be liable for incidental or consequential damages.

This warranty is valid only when oil-free, clean, dry, filtered air is used, where applicable.

Содержание ValveMate 7100

Страница 1: ...ValveMate 7100 Controller Operating Manual Electronic pdf files of Nordson EFD manuals are also available at www nordsonefd com...

Страница 2: ...0 years of industrial dispensing experience Most questions you will have are answered in this manual However if you need assistance please do not hesitate to contact EFD or your authorized EFD distrib...

Страница 3: ...ion 12 Indicator Lamps 13 Back Panel Markings 13 Typical Setup 14 Mounting the ValveMate 7100 15 External Power Adapter 16 Input Output Connections 17 Initiate Connections 18 Alarm OUT Connection 18 A...

Страница 4: ...iding dispense time ranges of 0 001 to 99 9 seconds Bright red LED display Push button purge feature Low air pressure optional tank low level detection or other alarm detection devices End of Cycle fe...

Страница 5: ...of electric shock Disconnect power before removing covers and or disconnect lock out and tag switches before servicing electrical equipment If you receive even a slight electrical shock shut down all...

Страница 6: ...rvicing high pressure equipment A jet of high pressure fluid can cut like a knife and cause serious bodily injury amputation or death Fluids penetrating the skin can also cause toxic poisoning Any inj...

Страница 7: ...t operate equipment unless safety guards doors and covers are intact and automatic interlocks are operating properly Do not bypass or disarm any safety devices Keep clear of moving equipment Before ad...

Страница 8: ...ency stop buttons shutoff valves and fire extinguishers are located Preventive Maintenance As part of maintaining continuous trouble free use of this product Nordson EFD recommends the following simpl...

Страница 9: ...ulations after one time use Do not clean components with strong solvents MEK acetone THF etc Clean cartridge retainer systems and barrel loaders with mild detergents only To prevent fluid waste use No...

Страница 10: ...mum Electrical input connector Switchcraft L722RA or equivalent locking type External power adapter 100 240 VAC 10 50 60Hz input 24 VDC 5 0 63 Amp output Switchcraft S761K locking DC plug or equivalen...

Страница 11: ...SJ T11363 2006 Indicates that this toxic or hazardous substance contained in all the homogeneous materials for this part according to EIP A EIP B EIP C is below the limit requirement in SJ T11363 2006...

Страница 12: ...on will provide different results according to the selected MODE TIME SET Pressing the buttons will decrement or increment the valve on time In SETUP or TEACH mode pressing both buttons simultaneously...

Страница 13: ...ng that the maximum air input pressure is 7 0 bar 100 psi Excessive air input pressure may damage the equipment Foot Pedal Finger Switch Connector Switch symbol identifies the connector for a momentar...

Страница 14: ...from the reservoir If using an EFD tank open the pressure relief valve as well Before opening the reservoir check the pressure gauge to verify that the pressure is zero 0 On all EFD cartridge reservoi...

Страница 15: ...ure the bracket Use the universal mounting bracket included to mount the controller either over or under the cabinet The bracket allows the controller to pivot 30 from a horizontal position When mount...

Страница 16: ...Sales and service of Nordson EFD dispensing systems are available worldwide External Power Adapter A universal 24 VDC remote power supply with a locking ring DC connector is included with each ValveM...

Страница 17: ...e CC initiate inputs Outputs include an Alarm Out End of Cycle EOC and a 24 VDC courtesy power 5 24 VDC INIT Dispense initiate input activated with a 5 24 VDC input voltage EOC OUT End of Cycle feedba...

Страница 18: ...fer to the How to instructions on page 23 to enable When enabled as an alarm input the CC INIT on pins 7 and 8 is connected to a normally closed switch such as a low level reservoir float switch Pins...

Страница 19: ...ATE 5 24 VDC 3 mA AT 5VDC 19 mA AT 24 VDC POWER IN 24 VDC 0 63 A MAX INPUTS OUTPUTS SWITCH CLOSURES 24 VDC MAX 100 mA MAX CC INIT NO SWITCH 19 mA MAX or COURTESY SUPPLY 24 VDC 200 mA MAX ALARM IN NC S...

Страница 20: ...tank cartridge reservoirs 3 m 9 ft of 6 mm OD air line is supplied Using the 6 mm push in fitting supplied connect one end to the P N 7016230 air tee Connect the other end of the air line by pushing...

Страница 21: ...Setup Checklist 1 Air pressure to ValveMate 7100 is set to 4 8 bar 70 psi 1 2 Initiate connection and I O are wired correctly 2 3 Valve and fluid reservoir are properly connected 3 4 Valve is set up a...

Страница 22: ...d from the system Adjust the tank pressure or valve stroke knob to set a flow rate that is not too low or too high A high flow rate will make setting up a small dot difficult or could cause splashing...

Страница 23: ...between TIME and STEADY operation Step 3 When appears on LED display press Mode button to return to RUN How to Use the TEACH Mode Step 1 Press MODE button and scroll to TEACH Step 2 Press and hold CYC...

Страница 24: ...adout Step 1 Press MODE button and scroll to STEADY Step 2 Press and hold until Aon or Aof is visible Step 3 Press button one time Step 4 Press or button to toggle between for BAR and for PSI PSI Form...

Страница 25: ...re available worldwide Replacement Parts Part Description 7026520 KIT VALVE SOLENOID 24VDC 1 8W WITH CONN 7026519 KIT POWER SUPPLY DC EXTERNAL 7100 7140 not shown 7026543 KIT DC CABLE ASSEMBLY 2M LOCK...

Страница 26: ...h as air cylinders are not causing a pressure drop in the ValveMate 7100 input air line Unit is not responding to the initiate signal Check to make sure the unit is not in a mode other than RUN The re...

Страница 27: ...ValveMate 7100 Controller 27 www nordsonefd com info nordsonefd com 1 401 431 7000 Sales and service of Nordson EFD dispensing systems are available worldwide Notes...

Страница 28: ...incompatible with equipment when the equipment is installed and operated in accordance with factory recommendations and instructions Nordson EFD will repair or replace free of charge any defective pa...

Отзывы: