ValveMate 7100 Controller
23
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
How To
How to Make On-the-Fly (OTF) Time Adjustments in RUN Mode
Step 1 Press CYCLE
button to enable OTF; display will blink.
Step 2 Press
or
buttons to adjust valve on time.
Step 3 Press CYCLE
button to disable OTF; display no longer blinks.
How to Set Controller to STEADY Mode
Step 1 Press MODE
button and scroll to STEADY.
Step 2 Press
or
to toggle between TIME and STEADY
operation.
Step 3 When
appears on LED display, press Mode button to return to RUN.
How to Use the TEACH Mode
Step 1 Press MODE
button and scroll to TEACH.
Step 2 Press and hold CYCLE
button or depress the foot pedal in the TEACH mode. LED display
will begin “flashing” before TEACH function begins.
Step 3 Add incremental time by continued press and hold of CYCLE
button or depress and hold
the foot pedal.
Step 4 To fine-tune programmed pulse time, press
or
to decrease / increase time.
Step 5 Press both
to 0.000 out time and restart the TEACH process.
How to Use PURGE Mode
Step 1 Press MODE
button and scroll to PURGE.
Step 2 Press CYCLE
button or depress foot pedal to purge dispense valve.