background image

Square Wave 745NC Non-Contact Dispense Valve

4

www.nordsonefd.com   [email protected]

   +1-401-431-7000    Sales and service of Nordson EFD dispensing systems are available worldwide.

Installation

1.  Mount valve utilizing the M4 mount hole on actuation body.

2.  Connect fluid supply line to fluid inlet fitting using 0.125" ID tubing. 

3.  Connect fluid supply line to reservoir.

4.  Connect valve control air to a constant air source between 4.8–6.3 bar (70–90 psi).

The Square Wave 745NC valve is recommended to be actuated using a spike and hold driver circuit. 
The valve requires a 24 VDC pulse for 1 ms minimum to actuate the valve. This is then reduced to 
5 VDC for the remaining period that the valve is open.

CAUTION

Failure to reduce the voltage will result in permanent damage to the actuation solenoid if the valve is left 
on longer than 30 ms.

To avoid damaging the actuation solenoid, do not cycle the valve at continuous high frequencies for 
periods greater than 30 minutes. The actuation solenoid requires periodic dwell time to protect coil 
integrity and performance.

Signal parameters:

 

 

Minimum on time: 1 ms

 

 

Minimum off time: 1 ms

 

 

Spike voltage (supply): 24 VDC

 

 

Hold voltage: 5 VDC

 

 

High current magnitude: 1.0 Amp

 

 

Maximum hold current: 300 mA 

 

 

Minimum operating frequency:  

 

 

 

100Hz (see Figure #1 below for frequency/duty cycle capability of 24W valve)

 

 

Maximum operating frequency: 500Hz

Frequency 

(Hz)

Duty Cycle

30%

40%

50%

60%

70%

100
150
200
250
300
350

n/a

400

n/a

n/a

450

n/a

n/a

500

n/a

n/a

n/a

Figure 1

Содержание 745NC

Страница 1: ...Square Wave 745NC Non Contact Dispense Valve Operating Manual Electronic pdf files of Nordson EFD manuals are also available at www nordsonefd com...

Страница 2: ...ur no compromise quality standards If you feel that you are not receiving all the support you require or if you have any questions or comments I invite you to write or call me personally Our goal is t...

Страница 3: ...ce Maximum cycle time 24 W solenoid 15 ms open and close once 4 W solenoid Continuous Minimum dispensing frequency 24 W solenoid 50Hz 4 W solenoid Continuous Maximum dispensing frequency 24 W solenoid...

Страница 4: ...o 5 VDC for the remaining period that the valve is open CAUTION Failure to reduce the voltage will result in permanent damage to the actuation solenoid if the valve is left on longer than 30 ms To avo...

Страница 5: ...spike voltage to actuate the valve The spike and hold driver circuit will apply the spike voltage from 1 to 30 ms before transitioning to the hold voltage CAUTION Not using a spike and hold driver ci...

Страница 6: ...ning nut to release nozzle plate c Set valve stroke between 10 20 on reference ring d Cycle valve at 50Hz minimum at 50 duty for purging CAUTION CAUTION for 24 watt solenoid only Minimum dispensing fr...

Страница 7: ...re 3 Dispensing volume as a function of frequency and pressure 101 6 m 0 004 nozzle Bullet solenoid cable NOTE Use the blue and brown wires of the bullet solenoid cable for BackPack valve actuation Th...

Страница 8: ...t seal groove is facing upwards and expanded fully in its groove 6 Replace with new needle assembly Insert into actuation body ensuring that piston seal is not damaged 7 Reassemble the upper stroke co...

Страница 9: ...the bullet solenoid 4 Engage wrench flats on bullet solenoid and rotate counterclockwise to remove When loose pull bullet solenoid up slowly to release 5 Place a light film of PTFE grease on O rings...

Страница 10: ...S 7028729 Chamber seat plate 7028728 Nozzle 0 004 7028731 Nozzle 0 005 7028732 Nozzle 0 006 7028733 Nozzle 0 007 7028734 Actuator body 7028735 Fluid inlet fitting 7020671 Fluid body O ring Buna N 7028...

Страница 11: ...ged Bullet solenoid may not be actuating Replace solenoid Steady drip A steady drip can be caused by a worn needle and seat or a particle holding the needle off the seat Clean and inspect the needle a...

Страница 12: ...incompatible with equipment when the equipment is installed and operated in accordance with factory recommendations and instructions Nordson EFD will repair or replace free of charge any defective pa...