5. Before Installing a new fireplace
Several European countries have local regulations for
installation of fireplaces, which change regularly. It is
the responsibility of the client that these regulations are
complied with in the country/region where the fireplace
is installed.
Nordpeis AS is not responsible for incorrect installation.
Important to check
• distance from firebox to combustible/flammable
materials
• insulation materials/requirements between
fireplace surround and back wall
• size of floor plates in front of fireplace if required
• flue connection between firebox and chimney
• insulation requirements if flue passes through a
flammable wall
Chimney Draft
Compared to older models, the clean burning fireplaces
of today put significantly higher demands on the
chimney. Even the best fireplace will not work properly
if the chimney does not have the right dimensions or
is not in good working order. The draught is mainly
controlled by gas temperature, outside temperature, air
supply as well as the height and inner diameter of the
chimney. The diameter of the chimney should never
be less than that of the flue/chimney collar. At nominal
effect there should be a negative pressure of 12 to 25
Pascal.
The draft increases when:
• The chimney becomes warmer than the outside air
• The active length of the chimney over the hearth
increases
• Good air supply to the combustion
It can be difficult to obtain the right draught conditions
in case the chimney is too large relative to the fireplace,
as the chimney does not heat up well enough. In
such cases you should contact professional for
evaluation of possible measures. If necessary,
contact a chimney sweeper. The product is type
tested and should be connected to a chimney that is
dimensioned for the smoke gas temperature indicated
in the CE declaration. When necessary, contact a
professional in advance.
Attention! It is recommended to use a qualified
professional when installing a new fireplace.
Air supply (=mm AIR)
A set for fresh air supply is available as an accessory.
This will ensure that the air supply to the combustion
chamber is less affected by ventilation systems, kitchen
fans and other factors which can create a down-draught
in the room. In all new constructions, we strongly
recommend the product is designed and prepared
for direct supply of outside air. In older houses also,
the use of fresh air supply set is also recommended.
4. Technical information:
Salzburg R / Salzburg R Extension Base /
Salzburg R +1
Minimum distances to
combustible materials
(*) with heat shield
Back 30mm (*)
200 mm
200 mm (+1)
Side 450mm (*)
450 mm
450 mm (+1)
CO-content of flue gas
@ 13%O
2
<1500 mg/m³
Flue gas temperature
199°C
Thermal output
36,6 kWh
Thermal storage
capacity
100% after 4,0 hrs
50% after 11,2 hrs
25% after 17,9 hrs
Energy efficiency
> 65
%
Nominal heat output
during discharge period
(100%-25%)
2,1 kW
Chimney draft
12 Pa
Length of wood logs
350 mm
Weight (kg)
675 /
705 (Extension Base)
Weight (+1) (kg)
890
Load size (kg)
2 kg
Max nr. loads
5
Loading interval
45 min
Содержание CO-SAL06-100
Страница 24: ...24 Salzburg R mm air chimney 630 452 503 845 1800 1580 150 160 100 315 Fig 1 ...
Страница 25: ...25 Salzburg R Extension Base mm air chimney Fig 1 A 630 503 845 650 1998 150 100 1778 358 315 ...
Страница 26: ...26 Salzburg R 1 mm air chimney Fig 1 B 630 452 503 1265 2220 2000 150 160 100 315 ...
Страница 30: ...30 FIG 3 4 20b FIG 22 44 FIG 3a 20b FIG 22 44 FIG 3 4 44 ...
Страница 60: ...60 FIG 35 SALZBURG R SALZBURG R 1 SALZBURG R EXTENSION BASE CERAMIC CATALIST 1 3 LA SAL06 070 4 2 ...
Страница 65: ...65 1 2 FIG Z FIG 44 SALZBURG R SALZBURG R 1 SALZBURG R EXTENSION BASE A c r y l A cryl ...
Страница 70: ...70 ...
Страница 71: ...71 ...
Страница 72: ...72 Nordpeis AS Gjellebekkstubben 9 11 N 3420 LIERSKOGEN Norway www nordpeis no ...