During the start-up phase, or after a new replacement cylinder has been fitted, the maximum water level can be
attained. When the maximum water level has been reached, the inlet valve closes briefly; this is a normal occurrence
during the steam cylinder concentration phase. The length of this phase can vary; it lasts until the cylinder has reached
the nominal rating. It can be examined by pressing button T1 twice at any time (see chapter 5.2)

5.4 Servicing and system messages

The electronic control unit with microprocessor continuously monitors the operation of the MinAir. Eventually
deviations from the operating condition (U-codes) will be shown on the display.

Code

Code "U1" is a servicing signal. 

‘’U1’’

The steam cylinder can no longer attain the nominal output and needs, therefore, to be cleaned or perhaps replaced
(refer to chapter 6.3). Code "U1" is a purely servicing code. The unit does not switch off automatically and the
humidifier continues to function at a reduced output. Acknowledgment is affected by the reset procedure.

Code

Message ‘’excess current’’

‘’U2’’

Whenever there is excess current (140% of the nominal value) during normal operations, the humidifier switches its
steam production off automatically for safety reasons. After the fault has been rectified, the humidifier is put back into
operation by pressing T1.

Code

The humidifier tries to fill the steam cylinder, without reaching the required steam capacity.

‘’U3’’

Possible causes are interrupted water supply, a defective contactor relay or inlet valve, or overpressure in the steam line
for eg. due to kinked steam hose. The humidifier switches itself off automatically after 30 minutes. After the fault has
been rectified, the humidifier is put back into operation by pressing T1 (arrow upwards).

Code

Micro controller displays no code.

‘’U4’’

This signal appears if a replacement electronic control unit has been fitted to the humidifier without being code, which
prevents the humidifier from operating. The signal disappears as soon as the electronic controls unit has been coded
according to the settings shown on the coding sticker inside the unit.

5.5 Safety functions

NORDMANN humidifiers are protected against running dry, i.e. the power is cut off automatically as soon as the
electrodes in the steam cylinder protrude above the water level.
If current consumption becomes excessive (25% above the nominal level), the outlet valve is opened automatically.
Because the electrodes are then in contact with less water, current consumption falls back to the nominal value.
If current fails to fall below 140% of the nominal level, even after several drainage operations, the humidifier turns
itself off automatically and the failure message "U2" appears on the LED display.

5.6 Remote indication

A standard, potential-free relay output enables the alarm messages U1, U2 and U3 to be remotely displayed.

Содержание MinAir

Страница 1: ...NORDMANN E N G I N E E R I N G Dampfluftbefeuchter MinAir Steam Humidifier MinAir Humidificateur à vapeur MinAir Betriebsanleitung Operating Instructions Mode d emploi NORDMANN E N G I N E E R I N G ...

Страница 2: ......

Страница 3: ...English 1 Safety Instructions 9 2 Installation 9 3 Water connections 10 4 Electrical connections 10 5 Putting into operation 11 6 Maintenance 13 7 Technical specifications 19 Table des matières Français 1 Consignes de sécurité 14 2 Montage 14 3 Raccordement hydraulique 15 4 Raccordement électrique 15 5 Mise en service 16 6 Entretien régulier 18 7 Données techniques 19 ...

Страница 4: ...hfolgenden Anlageteilen einzuhalten Zur Erleichterung der Montage wird mit jedem Dampfverteiler Rohr eine selbstklebende Montageschablone mitgeliefert Die Dampfverteiler Rohre von NORDMANN sind so konstruiert dass das Rohr bei einer horizontalen Montage ein Gefälle von 3 aufweist und damit der Abfluss des Kondensats sichergestellt ist 2 4 Installation des Dampfschlauches Die Installation des Dampf...

Страница 5: ...trieb mit behandeltem Wasser kontaktieren Sie bitte Ihren NORDMANN Fachhändler Bei einem Wasserdruck von 1 10 bar 0 1 1 MPa ist der direkte Anschluss an das Leitungsnetz möglich Bei einem Leitungsdruck über 10 bar 1 MPa erfolgt der Anschluss über ein Druckreduzierventil eingestellt auf 4 6 bar 0 4 0 6 MPa In jedem Fall ist darauf zu achten dass die Wasserleitungen vor dem Anschluss an den Befeucht...

Страница 6: ...anzeige Anzeige der relativen Luftfeuchte die vom angeschlossenen Feuchtefühler gemessen wird Bei Dampfproduktion ist der rechte Dezimalpunkt aktiv Taste T1 Pfeil aufwärts Mit dieser Taste kann nach einmaligem Betätigen der eingestellte Sollwert auf der LED Anzeige abgerufen werden Nach dem zweiten Betätigen erscheint der Status des Füllstandsensors L 0 Sensor nicht bedeckt L 1 Sensor bedeckt d h ...

Страница 7: ...lgt durch Betätigen der Taste T1 Pfeil aufwärts Meldung Der Befeuchter versucht den Zylinder zu füllen ohne dass die angeforderte Dampfleistung erreicht wird U3 Mögliche Ursachen sind eine unterbrochene Wasserzufuhr ein defektes Leistungsrelais oder Einlassventil oder Überdruck in der Dampfleitung z B wegen geknicktem Dampfschlauch Nach 30 Minuten erfolgt die automatische Abschaltung des Befeuchte...

Страница 8: ...fekt der Dampfzylinder ist verbraucht und muss ersetzt werden das Leistungsrelais ist defekt der Feuchtefühler ist nicht richtig angeschlossen 6 3 Austausch des Zylinders Die Lebensdauer eines Dampfzylinders ist abhängig von der Betriebszeit sowie der Härte des Wassers Der Zylinder sollte ersetzt werden wenn die System Meldung U1 angezeigt wird Der Befeuchter kann unter Umständen noch einige Zeit ...

Страница 9: ...the duct ensure this minimum distance is maintained For ease of the assembly an adhesive assembly template is supplied with each steam distribution pipe NORDMANN s steam distribution pipes are designed so that when fitted straight an automatic decline of 3 allows any condensate to drain properly 2 4 Laying the steam hose Install the steam hose in accordance with Fig 5 The length of the steam hose ...

Страница 10: ...The humidifiers are designed to operate on ordinary tap water only If you intend using treated water consult your NORDMANN representative Where the water pressure is between 1 and 10 bar 0 1 to 1 MPa the unit can be connected directly to the water supply If it is over 10 bar 1MPa connection must be via a pressure reduction valve set to 4 6 bar 0 4 0 6 MPa Water feed pipes must be thoroughly flushe...

Страница 11: ...ay will light up as long the humidifier is producing steam Button T1 arrow upwards After pressing this button once the nominal set point will be shown on the LED display After pressing the button a second time the status of the maximum level sensor will be shown on the LED display L 0 Max Level sensor is not activated L 1 Max level sensor is activated e g maximum possible water level has been reac...

Страница 12: ... Code The humidifier tries to fill the steam cylinder without reaching the required steam capacity U3 Possible causes are interrupted water supply a defective contactor relay or inlet valve or overpressure in the steam line for eg due to kinked steam hose The humidifier switches itself off automatically after 30 minutes After the fault has been rectified the humidifier is put back into operation b...

Страница 13: ...let valve is blocked or damaged The steam cylinder is worn out and needs to be replaced The power relay is defective The humidity sensor is not connected properly 6 3 Replacing the cylinder The serviceable life of the steam cylinder is dependent on the hardness of the tap water used and the unit s actual ope rating hours The cylinder should be replaced when the system message U1 appears on the LED...

Страница 14: ... que les ouvertures de sortie vapeur soient toujours dirigées verticalement par rapport au flux d air Dans le cas d une implantation horizontale les ouvertures de sortie vapeur doivent être dirigées vers le haut Chaque rampe de distribution est livrée avec un gabarit de fixation pour faciliter le montage de la rampe dans la gaine de ventilation Les rampes de distribution NORDMANN sont conçues en a...

Страница 15: ... eau traitée consulter votre distributeur NORDMANN Le raccordement direct au réseau d eau est possible entre 1 et 10 bar 0 1 à 1 MPa de pression Si la pression du réseau est supérieure à 10 bar 1 MPa le raccordement se fera via une soupape de réduction de pression réglée entre 4 et 6 bar 0 4 0 6 MPa Dans tous les cas il faut veiller à bien rincer la conduite d eau alimentant l humidificateur avant...

Страница 16: ... l appareil produit de la vapeur le point décimal de droite est actif Touche T1 Flèche vers le haut En appuyant une fois sur cette touche on interroge la valeur de consigne actuelle En appuyant une deuxième fois sur cette touche on affiche l état du détecteur de niveau haut L 0 détecteur inactif L 1 détecteur actif niveau max dans le cylindre est atteint Après 10 secondes l afficheur revient en mo...

Страница 17: ...ité La remise en route de l humidificateur après avoir résolu le problème se fait en appuyant une fois sur la touche T1 Code Remplissage permanent U3 Une des phases d alimentation électrique est coupée ou alors il n y a pas d eau dans le cylindre car l alimentation en eau est interrompue L humidificateur s arrêtera automatiquement après 30 minutes La remise en route de l humidifica teur après avoi...

Страница 18: ...e débit de la vanne d alimentation est bouché défectueux Le cylindre vapeur a besoin d être remplacé Le contacteur est défectueux 6 3 Remplacement du cylindre à vapeur La durée de vie d un cylindre vapeur dépend de la durée de fonctionnement et de la dureté de l eau utilisée Le cylindre doit être changé lorsque le code d entretien U1 apparaît sur l afficheur Après l apparition du message l humidif...

Страница 19: ...ession d eau 1 10 bar 0 1 1 MPa Sämtliche Komponenten unterliegen ständigen Fabrikationskontrollen und gewährleisten den hohen Qua litätsstandard der Geräte Das Unter nehmen NORDMANN ist nach ISO9001 2000 zertifiziert und die Fertigungswerkstätte wird regelmäs sig durch den TÜV Product Service Deutschland überwacht All components undergo continuous checks by the manufacturer thereby guaranteeing t...

Страница 20: ...r Manufacturer Nordmann Engineering AG Postfach CH 4143 Dornach 1 Schweiz Bruggfeldweg 11 CH 4147 Aesch Schweiz Tel 41 61 467 76 66 Fax 41 61 467 76 77 E mail info nordmann engineering com Internet www nordmann engineering com 821 0704 D E F ...

Отзывы: