On/Off hysteresis of the supply and the exhaust fan (2-fan operation)
-6
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
35
36
37
38
39
40
41
42
43
44
45
Actual temperature in °C
Exhaust Air
Supply Air
On
Off
Temperature dif
ference to setpoint in °C
Supply
Air
Exhaust
Air
Setpoint
-5
5
40 °C
-4
4
-3
3
-2
2
-1
1
0
0
1
-1
2
-2
3
-3
4
-4
5
-5
Example with setpoint value 40°C:
Hysteresis Exhaust fan 4°C: The exhaust fan switches off if the temperature is 2 °C below the setpoint value and
switches on if the temperature is 2 °C above the setpoint value.
Hysteresis supply fan 2 °C: The supply fan switches off if the temperature is 1 °C below the setpoint value and switches
on if the temperature is 1 °C above the setpoint value.
Note
: If the supply fan is controlled with the
“RLS” option
de-
pendent on the heating voltage (supply fan is running, when the
heating voltage contactor is switched on)
all software settings
of the supply fan are without function
.
In order to achieve an optimum steam formation in the steam
bath cabin when operating the Nodmann AT4 D with a supply
and a exhaust fan (2-fan mode) the ON and Off switching points
can be indiviually set with the hysteresis value in °C (steam bath
operation) or %rh (caldarium operation). The fans are switched off
when the temperature/humidity drops below the septpoint value
by the half of the set hysteresis value and are switched on when
the temperature/humidity exceeds the setpoint value by the half
of the set hysteresis value.