10
2.9
Setting-up temperature sensor monitoring function
In order to detect a manipulation on the temperature sensor, the steam bath control features the function
“Instab.Func”. If this function is activated the temperature curve of the temperature sensor is monitored
during steam bath operation. If the temperature decreases by cooling the temperature sensor (e.g. by
the use of a cool rag) within a certain time “Time Range” by more than the set temperature value “Temp
Range”, the steam generator is blocked for a certain time “Lock Time”. If the blocking time has elapsed
the steam generator is enabled again.
Note: temperature monitoring is activate only during steam bath operation and if the door of the steam
bath cabin is closed.
Select “
Instab.Temp
” in the engineering menu, then press the
<Set>
key. Select “
Instab.Func
”, then press
the
<Set>
key. In the upcoming display activate the monitoring function (On), then press the
<Set>
key.
Now, determine the desired settings for the temperature sensor monitoring:
• “
Temp Range
”:
Temperature range
Factory setting:
10 °C
Setting range:
1…30 °C
• “
Time Range
”:
Time span for the temperature monitoring
Factory setting:
10 seconds
Setting range:
1…60 seconds
• “
Lock Time
”:
Blocking time for steam production
Factory setting:
120 seconds
Setting range:
1…600 seconds
Instab.Temp.
Instab.Func.:Aus
Esc
Set
Instab.Temp.
Temp Range :10°C
Time Range :10s
Lock Time :120s
Instab.Func.:On
Esc
Set
Instab.Temp.
Temp Range :10°C
Time Range :10s
Lock Time :120s
Instab.Func.:On
Esc
Set
Instab.Temp.
Temp Range :10°C
Time Range :10s
Lock Time :120s
Instab.Func.:On
Esc
Set
Instab.Temp.
Temp Range :10°C
Time Range :10s
Lock Time :120s
Instab.Func.:On
Esc
Set
Engineering
Stop Mode :Switch
Instab.Temp.:Set
FactoryReset:Set
Min.Request :25/20%
Count Down :Set
Esc
Set
Instab.Func.
Off
On
On
Esc
Set
Temp Range
10 °C
10 °C
Esc
Set
Time Range
10 s
10 s
Esc
Set
Lock Time
120 s
120 s
Esc
Set